Attention!! This is not the most recent version of this information model. You can find the most recent version
''here'' .
General information
Name: nl.zorg.HeartRate
Version: 3.4.1
HCIM Status:Final
Release: 2023
Release status: Prepublished
Release date: 15-10-2023
Metadata
DCM::CoderList
Kerngroep Registratie aan de Bron
DCM::ContactInformation.Address
*
DCM::ContactInformation.Name
*
DCM::ContactInformation.Telecom
*
DCM::ContentAuthorList
Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron
DCM::CreationDate
29-11-2012
DCM::DeprecatedDate
DCM::DescriptionLanguage
nl
DCM::EndorsingAuthority.Address
DCM::EndorsingAuthority.Name
PM
DCM::EndorsingAuthority.Telecom
DCM::Id
2.16.840.1.113883.2.4.3.11.60.40.3.12.3
DCM::KeywordList
hartfrequentie, vitale parameters, hartslag
DCM::LifecycleStatus
Final
DCM::ModelerList
Kerngroep Registratie aan de Bron
DCM::Name
nl.zorg.Hartfrequentie
DCM::PublicationDate
15-10-2023
DCM::PublicationStatus
Prepublished
DCM::ReviewerList
Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron
DCM::RevisionDate
17-11-2021
DCM::Supersedes
nl.zorg.Hartfrequentie-v3.4
DCM::Version
3.4.1
HCIM::PublicationLanguage
EN
Revision History
Uitvouwen
Only available in Dutch
Publicatieversie 1.0 (15-02-2013)
Publicatieversie 1.1 (01-07-2013)
Publicatieversie 1.2 (01-04-2015)
ZIB-141
Aanpassingen in SNOMED CT codes en omschrijvingen voor codelijst HartslagMethodeCodelijst n.a.v. review terminologie expert.
ZIB-234
HartMethodeCodelijst bevat een typefout, namelijk aplation i.p.v. Palpation.
ZIB-308
Prefix Overdracht weggehaald bij de generieke bouwstenen
ZIB-360
Palpatie als hartslagmethode in hartfrequentie
Incl. algemene wijzigingsverzoeken:
ZIB-94
Aanpassen tekst van Disclaimer, Terms of Use & Copyrights
ZIB-154
Consequenties opsplitsing Medicatie bouwstenen voor overige bouwstenen.
ZIB-200
Naamgeving SNOMED CT in tagged values klinische bouwstenen gelijk getrokken.
ZIB-201
Naamgeving OID: in tagged value notes van klinische bouwstenen gelijk getrokken.
ZIB-309
EOI aangepast
ZIB-324
Codelijsten Name en Description beginnen met een Hoofdletter
ZIB-326
Tekstuele aanpassingen conform de kwaliteitsreview kerngroep 2015
Publicatieversie 3.0 (01-05-2016)
ZIB-453
Wijziging naamgeving ZIB's en logo's door andere opzet van beheer
Publicatieversie 3.1 (04-09-2017)
ZIB-431
Gebruik van LOINC en SNOMED CT in vitale functies gerelateerde zorginformatiebouwstenen
ZIB-549
De Engelse naam van de bouwsteen en het rootconcept zijn niet correct
ZIB-564
Aanpassing/harmonisatie Engelse conceptnamen
Publicatieversie 3.2 (01-10-2018)
ZIB-509
Wat is de toegevoegde waarde van zib Polsfrequentie naast Hartfrequentie?
Publicatieversie 3.3 (06-07-2019)
ZIB-732
Een aantal Snomed codes blijken bij nadere controle invalide. Een aantal andere codes zijn inmiddels Inactive verklaard in SNOMED
Publicatieversie 3.4 (01-09-2020)
ZIB-881
HartslagSnelheid/hartslagFrequentie toevoegen met waardelijst
Publicatieversie 3.4.1 (01-12-2021)
ZIB-1575
Deprecated termen en waardelijsten uit de prepublicatie halen
Concept
The heart rate is the number of heartbeats per minute.
Purpose
Obtaining information on circulation and heart function by measuring the heartrate.
Evidence Base
Heart rate (electric or auscultatory rhythm of the ventricles) and pulse rate (tangible output in the peripheral arteries) are physiologically different things, but produce the same values in normal circulation (beats per minute) and are therefore used interchangeably by many healthcare providers (and laymen). This is however incorrect, as a patient’s pulse rate can be lower than their heart rate. Nevertheless, in daily practice, the pulse is usually palpated to measure heart rate and also written down as the heart rate. For this reason, the HeartRate information model, in addition to the PulseRate information model, offers the option to enter palpation as the HeartRateMeasurementMethod.
Information Model
Type
Id
Concept
Card.
Definition
DefinitionCode
Reference
NL-CM:12.3.1
HeartRate
Root concept of the HeartRate information model. This root concept contains all data elements of the HeartRate information model.
NL-CM:12.3.2
HeartRateValue
1
The heart rate measured as the number of heartbeats per minute.
NL-CM:12.3.4
HeartRateDateTime
1
Date and time of the heart rate measurement.
NL-CM:12.3.6
HeartRateMeasurementMethod
0..1
The method used to count and observe the heart rate.
NL-CM:12.3.3
Comment
0..1
Comment on any problems or factors that may influence the measurement.
48767-8 Annotation comment [Interpretation] Narrative
NL-CM:12.3.5
HeartbeatRegularity
0..1
Regularity of the heartbeat.
NL-CM:12.3.7
InterpretationHeartRate
0..1
Interpretation heart rate
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
HartfrequentieDatumTijd
Hartfrequentie Waarde
Hartslag Meet Methode
Hartslag Regelmatigheid
Toelichting
08-02-2013 6:43
126/min
Auscultatie
Hartslag onregelmatig
Misschien bigeminie?
Instructions
A Holter registration is a 24-hour ECG: an ECG with a very long measuring period.
References
1. Parelsnoer DCM Hartslag v0.98. [Online] Beschikbaar op: http://www.nictiz.nl/uploaded/FILES/htmlcontent/dcm/parelsnoer/Hartslag%20v0.64.pdf [Geraadpleegd: 19 februari 2015].
2. openEHR-EHR-OBSERVATION.heart_rate.v1 [Online] Beschikbaar op: http://www.openehr.org/knowledge/ [Geraadpleegd: 19 februari 2015].
Valuesets
HeartbeatRegularityCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.3.1
Binding: Required
Conceptname
Conceptcode
Codesystem name
Codesystem OID
Description
Pulse regular
271636001
SNOMED CT
2.16.840.1.113883.6.96
Hartslag regelmatig
Irregular heart beat
361137007
SNOMED CT
2.16.840.1.113883.6.96
Hartslag onregelmatig
HeartRateMeasurementMethodCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.3.2
Binding: Extensible
Conceptname
Conceptcode
Codesystem name
Codesystem OID
Description
Auscultation
37931006
SNOMED CT
2.16.840.1.113883.6.96
Auscultatie
Cardiac monitor surveillance
88140007
SNOMED CT
2.16.840.1.113883.6.96
Cardiale monitoring
Electrocardiographic monitoring
46825001
SNOMED CT
2.16.840.1.113883.6.96
Electrocardiografie
InterpretationHeartRateCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.3.3
Binding: Extensible
Conceptname
Conceptcode
Codesystem name
Codesystem OID
Description
Bradycardia
48867003
SNOMED CT
2.16.840.1.113883.6.96
Bradycardie
Normal heart rate
76863003
SNOMED CT
2.16.840.1.113883.6.96
Normale hartfrequentie
Tachycardia
3424008
SNOMED CT
2.16.840.1.113883.6.96
Tachycardie
This information model in other releases
Information model references
This information model refers to
--
This information model is used in
--
Technical specifications in HL7v3 CDA and HL7 FHIR
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
Downloads
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Prerelease 2023-1
SNOMED CT and LOINC codes are based on:
SNOMED Clinical Terms versie: 20230930 [R] (september 2023-editie)
LOINC version 2.76
Conditions for use are located on the mainpage
This page is generated on 31/10/2023 18:34:14 with ZibExtraction v. 9.3.8704.31782