HeartRate-v3.3(2019EN)

Uit Zorginformatiebouwstenen
Naar navigatie springen Naar zoeken springen


Attention!! This is not the most recent version of this information model. You can find the most recent version ''here''.

General information

Name: nl.zorg.HeartRate
Version: 3.3
HCIM Status:Final
Release: 2019
Release status: Prepublished
Release date: 31-01-2020


Back to HCIM list

Metadata

DCM::CoderList Kerngroep Registratie aan de Bron
DCM::ContactInformation.Address *
DCM::ContactInformation.Name *
DCM::ContactInformation.Telecom *
DCM::ContentAuthorList Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron
DCM::CreationDate 29-11-2012
DCM::DeprecatedDate
DCM::DescriptionLanguage nl
DCM::EndorsingAuthority.Address
DCM::EndorsingAuthority.Name PM
DCM::EndorsingAuthority.Telecom
DCM::Id 2.16.840.1.113883.2.4.3.11.60.40.3.12.3
DCM::KeywordList hartfrequentie, vitale parameters, hartslag
DCM::LifecycleStatus Final
DCM::ModelerList Kerngroep Registratie aan de Bron
DCM::Name nl.zorg.Hartfrequentie
DCM::PublicationDate 31-01-2020
DCM::PublicationStatus Prepublished
DCM::ReviewerList Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron
DCM::RevisionDate 16-05-2019
DCM::Supersedes nl.zorg.Hartfrequentie-v3.2
DCM::Version 3.3
HCIM::PublicationLanguage EN

Revision History

Concept

The heart rate is the number of heartbeats per minute.

Purpose

Obtaining information on circulation and heart function by measuring the heartrate.

Evidence Base

Heart rate (electric or auscultatory rhythm of the ventricles) and pulse rate (tangible output in the peripheral arteries) are physiologically different things, but produce the same values in normal circulation (beats per minute) and are therefore used interchangeably by many healthcare providers (and laymen). This is however incorrect, as a patient’s pulse rate can be lower than their heart rate. Nevertheless, in daily practice, the pulse is usually palpated to measure heart rate and also written down as the heart rate. For this reason, the HeartRate information model, in addition to the PulseRate information model, offers the option to enter palpation as the HeartRateMeasurementMethod.

Information Model


#HeartRateMeasurementMethodCodelist#9392#HeartbeatRegularityCodelist#9394#9393#9390#9391#9389


Type Id Concept Card. Definition DefinitionCode Reference
NL-CM:12.3.1 HeartRate Root concept of the HeartRate information model. This root concept contains all data elements of the HeartRate information model.
NL-CM:12.3.2 HeartRateValue 1 The heart rate measured as the number of heartbeats per minute.
8867-4 Heart rate
NL-CM:12.3.4 HeartRateDateTime 1 Date and time of the heart rate measurement.
NL-CM:12.3.6 HeartRateMeasurementMethod 0..1 The method used to count and observe the heart rate.
HeartRateMeasurementMethodCodelist
NL-CM:12.3.3 Comment 0..1 Comment on any problems or factors that may influence the measurement. Further explanation can be provided here as well.
48767-8 Annotation comment [Interpretation] Narrative
NL-CM:12.3.5 HeartbeatRegularity 0..1 Regularity of the heartbeat.
HeartbeatRegularityCodelist

Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page

Example Instances

Only available in Dutch

HartfrequentieDatumTijd HartfrequentieWaarde HartslagMeet
Methode
Hartslag
Regelmatigheid
Toelichting
08-02-2013 6:43 126/min Auscultatie Hartslag onregelmatig Misschien bigeminie?

Instructions

A Holter registration is a 24-hour ECG: an ECG with a very long measuring period.

References

1. Parelsnoer DCM Hartslag v0.98. [Online] Beschikbaar op: http://www.nictiz.nl/uploaded/FILES/htmlcontent/dcm/parelsnoer/Hartslag%20v0.64.pdf [Geraadpleegd: 19 februari 2015]. 2. openEHR-EHR-OBSERVATION.heart_rate.v1 [Online] Beschikbaar op: http://www.openehr.org/knowledge/ [Geraadpleegd: 19 februari 2015].

Valuesets

HeartbeatRegularityCodelist

Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.3.1 Binding: Extensible
Conceptname Conceptcode Codesystem name Codesystem OID Description
Pulse regular 271636001 SNOMED CT 2.16.840.1.113883.6.96 Hartslag regelmatig
Irregular heart beat 361137007 SNOMED CT 2.16.840.1.113883.6.96 Hartslag onregelmatig
Heart irregular [DEPRECATED] 248650006 SNOMED CT 2.16.840.1.113883.6.96 Hartslag onregelmatig

HeartRateMeasurementMethodCodelist

Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.3.2 Binding: Extensible
Conceptname Conceptcode Codesystem name Codesystem OID Description
Palpation 113011001 SNOMED CT 2.16.840.1.113883.6.96 Palpatie (DEPRECATED)
Auscultation 37931006 SNOMED CT 2.16.840.1.113883.6.96 Auscultatie
Cardiac monitor surveillance 88140007 SNOMED CT 2.16.840.1.113883.6.96 Cardiale monitoring
Electrocardiographic monitoring 46825001 SNOMED CT 2.16.840.1.113883.6.96 Electrocardiografie

This information model in other releases

Information model references

This information model refers to

--

This information model is used in

--

Technical specifications in HL7v3 CDA and HL7 FHIR

To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:

  • HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
  • HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR

Downloads

This information model is also available as pdf file or as spreadsheet

About this information

The information in this wikipage is based on Prerelease 2019-2
SNOMED CT and LOINC codes are based on:

  • SNOMED Clinical Terms version: 20190731 [R] (July 2019 Release)
  • LOINC version 2.64

Conditions for use are located on the mainpage
This page is generated on 03/02/2020 01:38:53 with ZibExtraction v. 4.0.7338.2051


Back to HCIM list