O2Saturation-v4.0(2024EN)

Uit Zorginformatiebouwstenen
Versie door Update bot (overleg | bijdragen) op 26 jun 2024 om 16:03 (Nieuwe pagina aangemaakt met '<!-- Hieronder wordt een transclude page aangeroepen --> {{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.12.10(EN)|1|O2Saturation-v4.0(2024EN)}} <!-- Tot hier de transclude page --> ==General information<!--hdGeneralInformation-->== Name<!--hdName-->: '''nl.zorg.O2Saturation''' link=O2Saturatie-v4.0(2024NL)<BR> Version<!--hdVersion-->: '''4.0''' <br> HCIM Status<!--hdStatus-->:Final<br> Release<!--hdPublication-->: '''2024''' <br> Rele...')
(wijz) ← Oudere versie | Huidige versie (wijz) | Nieuwere versie → (wijz)
Naar navigatie springen Naar zoeken springen



General information

Name: nl.zorg.O2Saturation NL.png
Version: 4.0
HCIM Status:Final
Release: 2024
Release status: Prepublished
Release date: 15-04-2024


Back 16.png Back to HCIM list

Metadata

DCM::CoderList Kerngroep Registratie aan de Bron
DCM::ContactInformation.Address *
DCM::ContactInformation.Name *
DCM::ContactInformation.Telecom *
DCM::ContentAuthorList Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron
DCM::CreationDate 29-11-2012
DCM::DeprecatedDate
DCM::DescriptionLanguage nl
DCM::EndorsingAuthority.Address
DCM::EndorsingAuthority.Name PM
DCM::EndorsingAuthority.Telecom
DCM::Id 2.16.840.1.113883.2.4.3.11.60.40.3.12.10
DCM::KeywordList zuurstofsaturatie, vitale parameters, saturatie
DCM::LifecycleStatus Final
DCM::ModelerList Kerngroep Registratie aan de Bron
DCM::Name nl.zorg.O2Saturatie
DCM::PublicationDate 15-04-2024
DCM::PublicationStatus Prepublished
DCM::ReviewerList Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron
DCM::RevisionDate 11-11-2021
DCM::Supersedes nl.zorg.O2Saturatie-v3.1
DCM::Version 4.0
HCIM::PublicationLanguage EN

Revision History

Only available in Dutch

Publicatieversie 1.0 (15-02-2013) - Publicatieversie 1.1 (01-07-2013) -

Publicatieversie 1.2 (01-04-2015)

ZIB-308 Prefix Overdracht weggehaald bij de generieke bouwstenen

Incl. algemene wijzigingsverzoeken:

ZIB-94 Aanpassen tekst van Disclaimer, Terms of Use & Copyrights
ZIB-154 Consequenties opsplitsing Medicatie bouwstenen voor overige bouwstenen.
ZIB-200 Naamgeving SNOMED CT in tagged values klinische bouwstenen gelijk getrokken.
ZIB-201 Naamgeving OID: in tagged value notes van klinische bouwstenen gelijk getrokken.
ZIB-309 EOI aangepast
ZIB-324 Codelijsten Name en Description beginnen met een Hoofdletter
ZIB-326 Tekstuele aanpassingen conform de kwaliteitsreview kerngroep 2015

Publicatieversie 3.0 (01-05-2016)

ZIB-453 Wijziging naamgeving ZIB's en logo's door andere opzet van beheer

Publicatieversie 3.1 (04-09-2017)

ZIB-431 Gebruik van LOINC en SNOMED CT in vitale functies gerelateerde zorginformatiebouwstenen
ZIB-564 Aanpassing/harmonisatie Engelse conceptnamen

Publicatieversie 4.0 (01-12-2021)

ZIB-1217 Consistent maken van de zib
ZIB-1476 DefinitionCode voor ExtraOxygenAdministration

Concept

Arterial oxygen saturation, also referred to as saturation, is an indicator for the amount of oxygen bound to the hemoglobin in the red blood cells of the arteries. The measurement is usually carried out as a transcutaneous measurement with a blood oxygen monitor or pulse oximeter. The saturation level is expressed as a percentage and should be over 95% in healthy people.

Purpose

Measuring and monitoring oxygen saturation is done to monitor the oxygenation, or the amount of bound oxygen in the arterial blood.
This HCIM concerns the peripherally measured oxygen saturation (SpO2). For the oxygen saturation measured as a blood-gas measurement (SaO2), the HCIM LaboratoryTestResults must be used.

Information Model


AnatomicalLocation-v1.0.3(2024EN)#2459#2461#2460#2463#2458O2Saturation-v4.0Model(2024EN).png


Type Id Concept Card. Definition DefinitionCode Reference
Block.png NL-CM:12.10.1 Arrowdown.pngO2Saturation Root concept of the O2Saturation information model. This root concept contains all data elements of the O2Saturation information model.
250554003 Measurement of oxygen saturation at periphery
PQ.png NL-CM:12.10.2 Arrowright.pngSpO2Value 1 The element contains the value of the indirect, peripheral measured O2 saturation.

The O2 saturation gives a percentage expressing the extent to which the blood’s hemoglobin is saturated with oxygen, the ratio of oxygen-saturated hemoglobin to hemoglobin. The measurement is done in places where sufficient light can get through the skin, such as a finger, toe or earlobe.

59408-5 Oxygen saturation in Arterial blood by Pulse oximetry
431314004 Peripheral oxygen saturation
TS.png NL-CM:12.10.3 Arrowright.pngSpO2SaturationDateTime 1 The moment (date and time) of the SpO2 measurement.
ST.png NL-CM:12.10.4 Arrowright.pngComment 0..1 Comment on the saturation measurement.
48767-8 Annotation comment [Interpretation] Narrative
BL.png NL-CM:12.10.5 Arrowright.pngExtraOxygenAdministration 0..1 Indication stating whether the measurement was done in a situation in which extra oxygen was administered.
266702001 Oxygen enrichment therapy
Verwijzing.png NL-CM:12.10.6 Arrowright.pngMeasuringLocation::AnatomicalLocation 1 Anatomical location where the SpO2 is measured.
Block.png AnatomicalLocation

Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page List2.png

Example Instances

Only available in Dutch

O2SaturatieDatumTijd SpO2Waarde ExtraZuurstofToediening Toelichting
08-02-2013 6:43 92% Ja Stijgt snel bij aanspreken

References

1. openEHR-EHR-OBSERVATION.indirect_oximetry.v1[Online] Beschikbaar op: http://www.openehr.org/knowledge/ [Geraadpleegd: 19 december 2014].

Traceability to other Standards

This health and care information model is in accordance with the information model template Measurement v1.0.

This information model in other releases

Information model references

This information model refers to

This information model is used in

--

Technical specifications in HL7v3 CDA and HL7 FHIR

To exchange information based on health and care information models, additional, more technical specifications are required.<BR> Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:

  • HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment Artdecor.jpg
  • HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR Fhir.png

Downloads

This information model is also available as pdf file PDF.png or as spreadsheet Xlsx.png

About this information

The information in this wikipage is based on Prerelease 2024-1
SNOMED CT and LOINC codes are based on:

  • SNOMED Clinical Terms versie: 20240331 [R] (maart 2024-editie)
  • LOINC version 2.77

Conditions for use are located on the mainpage List2.png
This page is generated on 25/04/2024 12:41:49 with ZibExtraction v. 9.3.8880.19756


Back 16.png Back to HCIM list