O2Saturation-v3.1(2020EN)
General information
Name: nl.zorg.O2Saturation
Version: 3.1
HCIM Status:Final
Release: 2020
Release status: Published
Release date: 01-09-2020
Metadata
DCM::CoderList | Kerngroep Registratie aan de Bron |
DCM::ContactInformation.Address | * |
DCM::ContactInformation.Name | * |
DCM::ContactInformation.Telecom | * |
DCM::ContentAuthorList | Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron |
DCM::CreationDate | 29-11-2012 |
DCM::DeprecatedDate | |
DCM::DescriptionLanguage | nl |
DCM::EndorsingAuthority.Address | |
DCM::EndorsingAuthority.Name | PM |
DCM::EndorsingAuthority.Telecom | |
DCM::Id | 2.16.840.1.113883.2.4.3.11.60.40.3.12.10 |
DCM::KeywordList | zuurstofsaturatie, vitale parameters, saturatie |
DCM::LifecycleStatus | Final |
DCM::ModelerList | Kerngroep Registratie aan de Bron |
DCM::Name | nl.zorg.O2Saturatie |
DCM::PublicationDate | 01-09-2020 |
DCM::PublicationStatus | Published |
DCM::ReviewerList | Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron |
DCM::RevisionDate | 31-12-2017 |
DCM::Supersedes | nl.zorg.O2Saturatie-v3.0 |
DCM::Version | 3.1 |
HCIM::PublicationLanguage | EN |
Revision History
Only available in Dutch
Publicatieversie 1.0 (15-02-2013) - Publicatieversie 1.1 (01-07-2013) -
Publicatieversie 1.2 (01-04-2015)
ZIB-308 | Prefix Overdracht weggehaald bij de generieke bouwstenen |
Incl. algemene wijzigingsverzoeken:
ZIB-94 | Aanpassen tekst van Disclaimer, Terms of Use & Copyrights |
ZIB-154 | Consequenties opsplitsing Medicatie bouwstenen voor overige bouwstenen. |
ZIB-200 | Naamgeving SNOMED CT in tagged values klinische bouwstenen gelijk getrokken. |
ZIB-201 | Naamgeving OID: in tagged value notes van klinische bouwstenen gelijk getrokken. |
ZIB-309 | EOI aangepast |
ZIB-324 | Codelijsten Name en Description beginnen met een Hoofdletter |
ZIB-326 | Tekstuele aanpassingen conform de kwaliteitsreview kerngroep 2015 |
Publicatieversie 3.0 (01-05-2016)
ZIB-453 | Wijziging naamgeving ZIB's en logo's door andere opzet van beheer |
Publicatieversie 3.1 (04-09-2017)
ZIB-431 | Gebruik van LOINC en SNOMED CT in vitale functies gerelateerde zorginformatiebouwstenen |
ZIB-564 | Aanpassing/harmonisatie Engelse conceptnamen |
Concept
Arterial oxygen saturation, also referred to as saturation, is an indicator for the amount of oxygen bound to the hemoglobin in the red blood cells of the arteries. The measurement is usually carried out as a transcutaneous measurement with a blood oxygen monitor or pulse oximeter. The saturation level is expressed as a percentage and should be over 95% in healthy people.
Purpose
Measuring and monitoring oxygen saturation is done to monitor the oxygenation, or the amount of bound oxygen in the arterial blood.
Information Model
Type | Id | Concept | Card. | Definition | DefinitionCode | Reference | ||||||
NL-CM:12.10.1 | O2Saturation | Root concept of the O2Saturation information model. This root concept contains all data elements of the O2Saturation information model. | ||||||||||
NL-CM:12.10.2 | SpO2Value | 1 | The element contains the value of the indirect, peripheral measured O2 saturation.
The O2 saturation gives a percentage expressing the extent to which the blood’s hemoglobin is saturated with oxygen, the ratio of oxygen-saturated hemoglobin to hemoglobin. The measurement is done in places where sufficient light can get through the skin, such as a finger, toe or earlobe. |
|
||||||||
NL-CM:12.10.3 | O2SaturationDateTime | 1 | The moment (date and time) of the SpO2 measurement. | |||||||||
NL-CM:12.10.4 | Comment | 0..1 | Comment on the saturation measurement. |
|
||||||||
NL-CM:12.10.5 | ExtraOxygenAdministration | 0..1 | Indication stating whether the measurement was done in a situation in which extra oxygen was administered. |
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
O2SaturatieDatumTijd | SpO2Waarde | ExtraZuurstofToediening | Toelichting |
08-02-2013 6:43 | 92% | Ja | Stijgt snel bij aanspreken |
References
1. openEHR-EHR-OBSERVATION.indirect_oximetry.v1[Online] Beschikbaar op: http://www.openehr.org/knowledge/ [Geraadpleegd: 19 december 2014].
Traceability to other Standards
This health and care information model is in accordance with the information model template Measurement v1.0.
This information model in other releases
- Release 2015, (Version 1.2)
- Release 2016, (Version 3.0)
- Release 2017, (Version 3.1)
- Prerelease 2018-2, (Version 3.1)
- Prerelease 2019-2, (Version 3.1)
- Prerelease 2021-2, (Version 4.0)
- Prerelease 2022-1, (Version 4.0)
- Prerelease 2023-1, (Version 4.0)
- Prerelease 2024-1, (Version 4.0)
Information model references
This information model refers to
- --
This information model is used in
- --
Technical specifications in HL7v3 CDA and HL7 FHIR
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
- HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
- HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
Downloads
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Release 2020
SNOMED CT and LOINC codes are based on:
- SNOMED Clinical Terms version: 20200731 [R] (July 2020 Release)
- LOINC version 2.67
Conditions for use are located on the mainpage
This page is generated on 29/09/2020 21:35:01 with ZibExtraction v. 4.0.7577.31095