O2Saturation-v4.0(2023EN)

Uit Zorginformatiebouwstenen
Versie door Update bot (overleg | bijdragen) op 26 okt 2023 om 16:15 (Nieuwe pagina aangemaakt met '<!-- Hieronder wordt een transclude page aangeroepen --> {{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.12.10(EN)|1|O2Saturation-v4.0(2023EN)}} <!-- Tot hier de transclude page --> ==General information<!--hdGeneralInformation-->== Name<!--hdName-->: '''nl.zorg.O2Saturation''' link=O2Saturatie-v4.0(2023NL)<BR> Version<!--hdVersion-->: '''4.0''' <br> HCIM Status<!--hdStatus-->:Final<br> Release<!--hdPublication-->: '''2023''' <br> Rele...')
(wijz) ← Oudere versie | Huidige versie (wijz) | Nieuwere versie → (wijz)
Naar navigatie springen Naar zoeken springen


Attention!! This is not the most recent version of this information model. You can find the most recent version ''here''.

General information

Name: nl.zorg.O2Saturation
Version: 4.0
HCIM Status:Final
Release: 2023
Release status: Prepublished
Release date: 15-10-2023


Back to HCIM list

Metadata

DCM::CoderList Kerngroep Registratie aan de Bron
DCM::ContactInformation.Address *
DCM::ContactInformation.Name *
DCM::ContactInformation.Telecom *
DCM::ContentAuthorList Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron
DCM::CreationDate 29-11-2012
DCM::DeprecatedDate
DCM::DescriptionLanguage nl
DCM::EndorsingAuthority.Address
DCM::EndorsingAuthority.Name PM
DCM::EndorsingAuthority.Telecom
DCM::Id 2.16.840.1.113883.2.4.3.11.60.40.3.12.10
DCM::KeywordList zuurstofsaturatie, vitale parameters, saturatie
DCM::LifecycleStatus Final
DCM::ModelerList Kerngroep Registratie aan de Bron
DCM::Name nl.zorg.O2Saturatie
DCM::PublicationDate 15-10-2023
DCM::PublicationStatus Prepublished
DCM::ReviewerList Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron
DCM::RevisionDate 11-11-2021
DCM::Supersedes nl.zorg.O2Saturatie-v3.1
DCM::Version 4.0
HCIM::PublicationLanguage EN

Revision History

Concept

Arterial oxygen saturation, also referred to as saturation, is an indicator for the amount of oxygen bound to the hemoglobin in the red blood cells of the arteries. The measurement is usually carried out as a transcutaneous measurement with a blood oxygen monitor or pulse oximeter. The saturation level is expressed as a percentage and should be over 95% in healthy people.

Purpose

Measuring and monitoring oxygen saturation is done to monitor the oxygenation, or the amount of bound oxygen in the arterial blood.
This HCIM concerns the peripherally measured oxygen saturation (SpO2). For the oxygen saturation measured as a blood-gas measurement (SaO2), the HCIM LaboratoryTestResults must be used.

Information Model


AnatomicalLocation-v1.0.3(2023EN)#2459#2461#2460#2463#2458


Type Id Concept Card. Definition DefinitionCode Reference
NL-CM:12.10.1 O2Saturation Root concept of the O2Saturation information model. This root concept contains all data elements of the O2Saturation information model.
250554003 Measurement of oxygen saturation at periphery
NL-CM:12.10.2 SpO2Value 1 The element contains the value of the indirect, peripheral measured O2 saturation.

The O2 saturation gives a percentage expressing the extent to which the blood’s hemoglobin is saturated with oxygen, the ratio of oxygen-saturated hemoglobin to hemoglobin. The measurement is done in places where sufficient light can get through the skin, such as a finger, toe or earlobe.

59408-5 Oxygen saturation in Arterial blood by Pulse oximetry
431314004 Peripheral oxygen saturation
NL-CM:12.10.3 SpO2SaturationDateTime 1 The moment (date and time) of the SpO2 measurement.
NL-CM:12.10.4 Comment 0..1 Comment on the saturation measurement.
48767-8 Annotation comment [Interpretation] Narrative
NL-CM:12.10.5 ExtraOxygenAdministration 0..1 Indication stating whether the measurement was done in a situation in which extra oxygen was administered.
266702001 Oxygen enrichment therapy
NL-CM:12.10.6 MeasuringLocation::AnatomicalLocation 1 Anatomical location where the SpO2 is measured.
AnatomicalLocation

Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page

Example Instances

Only available in Dutch

O2SaturatieDatumTijd SpO2Waarde ExtraZuurstofToediening Toelichting
08-02-2013 6:43 92% Ja Stijgt snel bij aanspreken

References

1. openEHR-EHR-OBSERVATION.indirect_oximetry.v1[Online] Beschikbaar op: http://www.openehr.org/knowledge/ [Geraadpleegd: 19 december 2014].

Traceability to other Standards

This health and care information model is in accordance with the information model template Measurement v1.0.

This information model in other releases

Information model references

This information model refers to

This information model is used in

--

Technical specifications in HL7v3 CDA and HL7 FHIR

To exchange information based on health and care information models, additional, more technical specifications are required.<BR> Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:

  • HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
  • HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR

Downloads

This information model is also available as pdf file or as spreadsheet

About this information

The information in this wikipage is based on Prerelease 2023-1
SNOMED CT and LOINC codes are based on:

  • SNOMED Clinical Terms versie: 20230930 [R] (september 2023-editie)
  • LOINC version 2.76

Conditions for use are located on the mainpage
This page is generated on 26/10/2023 15:51:40 with ZibExtraction v. 9.0.8682.20490


Back to HCIM list