General information
Name: nl.zorg.VisualAcuity
Version: 2.1.1
HCIM Status:Final
Release: 2024
Release status: Prepublished
Release date: 15-04-2024
Metadata
DCM::CoderList
*
DCM::ContactInformation.Address
*
DCM::ContactInformation.Name
*
DCM::ContactInformation.Telecom
*
DCM::ContentAuthorList
*
DCM::CreationDate
15-06-2020
DCM::DeprecatedDate
DCM::DescriptionLanguage
nl
DCM::EndorsingAuthority.Address
DCM::EndorsingAuthority.Name
*
DCM::EndorsingAuthority.Telecom
DCM::Id
2.16.840.1.113883.2.4.3.11.60.40.3.12.19
DCM::KeywordList
DCM::LifecycleStatus
Final
DCM::ModelerList
*
DCM::Name
nl.zorg.Visus
DCM::PublicationDate
15-04-2024
DCM::PublicationStatus
Prepublished
DCM::ReviewerList
DCM::RevisionDate
11-09-2023
DCM::Supersedes
nl.zorg.Visus-v2.1
DCM::Version
2.1.1
HCIM::PublicationLanguage
EN
Revision History
Only available in Dutch
Publicatieversie 1.0 (01-09-2020)
Publicatieversie 2.0 (01-12-2021)
ZIB-1412
zib Visus - code 'Anders, specificeer'
ZIB-1441
zib Visus definitiecode AfstandTotKaart
ZIB-1442
zib Visus AnatomischeLocatie en Lateraliteit
ZIB-1445
zib Visus zelfde DefinitieCode voor verschillende concepten
ZIB-1567
Element naam aanpassen
Publicatieversie 2.1 (10-06-2022)
ZIB-1595
Codesysteem VisusMeetkaart heeft verkeerd OID.
Publicatieversie 2.1.1 (15-10-2023)
ZIB-2020
Definitie van concept VisusWaarde aanpassen
Concept
Visual acuity is a measurement of sharpness of vision. It is a measure of the smallest details that someone can still distinguish.
Purpose
The aim is to determine the patient's visual functioning based ontheir visual acuity.
Evidence Base
Patient Population
Adults and children from the age that they can interpret a picture chart.
Information Model
Type
Id
Concept
Card.
Definition
DefinitionCode
Reference
NL-CM:12.19.1
VisualAcuity
Root concept of the VisualAcuity information model.This root concept contains all data elements of the VisualAcuity information model.
NL-CM:12.19.6
VisualAcuityMeasurementDevice
0..1
The device used measuring the visual acuity.
NL-CM:12.19.2
VisualAcuityType
0..1
Type of visual acuity measurement.
NL-CM:12.19.7
VisualAcuityMeasurementChart
0..1
The type of chart used for the visual acuity measurement.
NL-CM:12.19.8
DistanceFromChart
0..1
Distance to the chart in meters.
NL-CM:12.19.11
VisualAcuity
0..1
The measured visual acuity.
NL-CM:12.19.4
VisualAcuityDateTime
0..1
The date and time when the visual acuity was measured.
NL-CM:12.19.5
AnatomicalLocation
0..1
Indication and the laterality of the eye of which the visual acuity measurement relates to.
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
Visus
DatumTijd
MetingType
Decimale Visus
Meting Kaart
Afstand tot kaart
Lateraliteit
Meethulpmiddel
08-02-2020
Best gecorrigeerde visus
0.8
Snellen Letterkaart
5 meter
Links
08-02-2020
Gecorrigeerde visus
1.0
logaritmische E-hakenkaart
3 meter
Rechts
Met stenopeische opening
Traceability to other Standards
This health and care information model is based on the information model template Measurement- v1.0.
Valuesets
VisualAcuityMeasurementChartCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.19.3
Binding: Extensible
Conceptname
Conceptcode
Codesystem name
Codesystem OID
Description
Logarithmic E chart
1
VisusMeetkaart
2.16.840.1.113883.2.4.3.11.60.40.4.27.1
Logaritmische E-hakenkaart
Snellen chart
2
VisusMeetkaart
2.16.840.1.113883.2.4.3.11.60.40.4.27.1
Snellen Letterkaart
LEA Hayvarinen chart
3
VisusMeetkaart
2.16.840.1.113883.2.4.3.11.60.40.4.27.1
LEA symbolen kaart
Other
OTH
NullFlavor
2.16.840.1.113883.5.1008
Anders
VisualAcuityMeasurementDeviceCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.19.4
Binding: Extensible
Conceptname
Conceptcode
Codesystem name
Codesystem OID
Description
Pinhole visual acuity
419475002
SNOMED CT
2.16.840.1.113883.6.96
Met stenopeïsche opening (DEPRECATED)
Pinhole
257492003
SNOMED CT
2.16.840.1.113883.6.96
Met stenopeïsche opening
Other
OTH
NullFlavor
2.16.840.1.113883.5.1008
Anders
VisusAcuityTypeCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.19.2
Binding: Extensible
Conceptname
Conceptcode
Codesystem name
Codesystem OID
Description
Corrected visual acuity
397536007
SNOMED CT
2.16.840.1.113883.6.96
Gecorrigeerde visus (met eigen bril)
Uncorrected visual acuity
420050001
SNOMED CT
2.16.840.1.113883.6.96
Ongecorrigeerde visus
Best corrected visual acuity
419775003
SNOMED CT
2.16.840.1.113883.6.96
Best gecorrigeerde visus(met optimale bril)
Stereoscopic acuity
359750002
SNOMED CT
2.16.840.1.113883.6.96
Stereoscopische visus
Other
OTH
NullFlavor
2.16.840.1.113883.5.1008
Anders
This information model in other releases
Information model references
This information model refers to
This information model is used in
--
Technical specifications in HL7v3 CDA and HL7 FHIR
To exchange information based on health and care information models, additional, more technical specifications are required.<BR>
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
Downloads
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Prerelease 2024-1
SNOMED CT and LOINC codes are based on:
SNOMED Clinical Terms versie: 20240331 [R] (maart 2024-editie)
LOINC version 2.77
Conditions for use are located on the mainpage
This page is generated on 25/04/2024 12:43:21 with ZibExtraction v. 9.3.8880.19756