Attention!! This is not the most recent version of this information model. You can find the most recent version
''here''.
General information
Name: nl.zorg.Refraction 
Version: 1.1
HCIM Status:Final
Release: 2021
Release status: Prepublished
Release date: 01-12-2021
Metadata
DCM::CoderList |
*
|
DCM::ContactInformation.Address |
*
|
DCM::ContactInformation.Name |
*
|
DCM::ContactInformation.Telecom |
*
|
DCM::ContentAuthorList |
*
|
DCM::CreationDate |
17-5-2020
|
DCM::DeprecatedDate |
|
DCM::DescriptionLanguage |
nl
|
DCM::EndorsingAuthority.Address |
|
DCM::EndorsingAuthority.Name |
*
|
DCM::EndorsingAuthority.Telecom |
|
DCM::Id |
2.16.840.1.113883.2.4.3.11.60.40.3.12.20
|
DCM::KeywordList |
|
DCM::LifecycleStatus |
Final
|
DCM::ModelerList |
*
|
DCM::Name |
nl.zorg.Refractie
|
DCM::PublicationDate |
01-12-2021
|
DCM::PublicationStatus |
Prepublished
|
DCM::ReviewerList |
|
DCM::RevisionDate |
11-08-2021
|
DCM::Supersedes |
nl.zorg.Refractie-v1.0
|
DCM::Version |
1.1
|
HCIM::PublicationLanguage |
EN
|
Revision History
Uitvouwen
Only available in Dutch
Publicatieversie 1.0 (01-09-2020)
Publicatieversie 1.1 (01-12-2021)
ZIB-1420
|
zib Refractie definition code SfericalEquivalent
|
ZIB-1421
|
Zib Refractie vertaling
|
ZIB-1442
|
zib Visus AnatomischeLocatie en Lateraliteit
|
ZIB-1443
|
zib Refractie twee concepten met dezelfde definitiecode
|
ZIB-1449
|
zib Refractie diopter-eenheid (en UCUM-eenheden algemeen)
|
ZIB-1522
|
Aanpassing definitie sferische equivalent
|
Concept
The refraction measurement is a measurement with which the refractive error of the eye is determined. During the refraction measurement, the necessary correction is established: the spherical power (in diopter), the cylindrical power (in diopter), the axis direction(in degrees) for any cylindrical correction, the prism (in diopter)and any additional power of the reading area (in diopter), the so-called reading addition
Purpose
The purpose of a refraction measurement is to determine the correction (through glasses or lenses) with which the patient can see optimally.
Patient Population
Adults and children from the age that they can interpret a picture chart.
Information Model
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
Refractie DatumTijd
|
Refractie Methode
|
Refractie Lateraliteit
|
SferischeRefractie
|
CilindrischeRefractie
|
Sferische Refractie
|
Lees additie
|
Prisma
|
|
|
|
SferischeRefractieWaarde
|
CilindrischeRefractie Waarde
|
CilindrischeRefractieAs
|
Sferisch Equivalent
|
|
Prisma Waarde
|
PrismaBasis
|
1-1-2020
|
Subjectieve refractie
|
Rechts
|
+1.00
|
-0.75
|
90 graden
|
0.625
|
1.00
|
2.00
|
90
|
1-1-2020
|
Subjectieve refractie
|
Links
|
+0.5
|
-1.00
|
45 graden
|
0
|
1.00
|
1.50
|
45
|
12-1-2020
|
Objectieve refractie
|
Rechts
|
–
|
–
|
–
|
–
|
–
|
–
|
–
|
12-1-2020
|
Objectieve refractie
|
Links
|
–
|
–
|
–
|
–
|
–
|
–
|
–
|
Valuesets
RefractionMeasurementMethodCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.20.1
|
Binding: Extensible
|
Conceptname
|
Conceptcode
|
Codesystem name |
Codesystem OID
|
Description
|
Subjective refraction
|
397277005
|
SNOMED CT
|
2.16.840.1.113883.6.96
|
Subjectieve refractie
|
Objective refraction
|
397276001
|
SNOMED CT
|
2.16.840.1.113883.6.96
|
Objectieve refractie
|
This information model in other releases
Information model references
This information model refers to
This information model is used in
- --
Technical specifications in HL7v3 CDA and HL7 FHIR
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
- HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment

- HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR

Downloads
This information model is also available as pdf file
or as spreadsheet
About this information
The information in this wikipage is based on Pre-release 2021-2
SNOMED CT and LOINC codes are based on:
- SNOMED Clinical Terms version: 20210731 [R] (July 2021 Release)
- LOINC version 2.67
Conditions for use are located on the mainpage 