MedicationContraIndication-v2.0.1(2023EN)
General information
Name: nl.zorg.MedicationContraIndication
Version: 2.0.1
HCIM Status:Final
Release: 2023
Release status: Prepublished
Release date: 15-10-2023
Metadata
DCM::CoderList | * |
DCM::ContactInformation.Address | * |
DCM::ContactInformation.Name | * |
DCM::ContactInformation.Telecom | * |
DCM::ContentAuthorList | * |
DCM::CreationDate | 15-06-2020 |
DCM::DeprecatedDate | |
DCM::DescriptionLanguage | nl |
DCM::EndorsingAuthority.Address | |
DCM::EndorsingAuthority.Name | * |
DCM::EndorsingAuthority.Telecom | |
DCM::Id | 2.16.840.1.113883.2.4.3.11.60.40.3.9.14 |
DCM::KeywordList | |
DCM::LifecycleStatus | Final |
DCM::ModelerList | * |
DCM::Name | nl.zorg.MedicatieContraIndicatie |
DCM::PublicationDate | 15-10-2023 |
DCM::PublicationStatus | Prepublished |
DCM::ReviewerList | |
DCM::RevisionDate | 04-09-2023 |
DCM::Supersedes | nl.zorg.MedicatieContraIndicatie-v2.0 |
DCM::Version | 2.0.1 |
HCIM::PublicationLanguage | EN |
Revision History
Only available in Dutch
Publicatieversie 1.0 (01-09-2020)
Publicatieversie 1.1 (01-12-2021)
ZIB-1253 | Voorbeelden in zib MedicatieContraIndicatie aanpassen |
ZIB-1254 | Paragraaf "Concept" aanpassen |
ZIB-1268 | Engelse omschrijving Melder::Zorgverlener niet correct |
ZIB-1283 | Haakje weghalen bij eerste bullet bij Instructie |
ZIB-1401 | Voorbeeld incorrect bij MedicatieContraIndicatie |
Publicatieversie 2.0 (10-06-2022)
ZIB-1608 | Naam data-element EindDatum wijzigen naar EindDatumTijd |
ZIB-1765 | Deprecated SNOMED codes |
Publicatieversie 2.0.1 (15-10-2023)
ZIB-1863 | Schrijfwijze "contra-indication" consistent doorvoeren |
ZIB-1960 | Tekstuele wijzigingen zib MedicatieContraIndicatie |
ZIB-2009 | Spelfoutje (2x) contra-indication in elementen van MedicationContraIndication (2022) |
ZIB-2010 | Taalfoutje in beschrijving element van zib MedicationContraIndication (2022) |
Concept
A contraindication (CI) for medication safety is a condition or characteristic of a patient in which certain medicines may not be used, or only used under certain conditions.
Purpose
Contraindications should be taken into account with drug treatment. These are important for medication safety monitoring.
Evidence Base
A number of contraindications for medication safety are disorders that are also recorded as a problem (HCIM Problem) and/or as a warning (HCIM Alert) and not only as a medication contraindication .
In the Netherlands it is important to also capture these via the G standard (thesaurus 40) as a contraindication. Contra indications are used for medication safety. Through its use in these applications, important warnings/signals are given to healthcare providers.
Information Model
Type | Id | Concept | Card. | Definition | DefinitionCode | Reference | ||||||||
NL-CM:9.14.1 | MedicationContraIndication | Root concept of the MedicationContraIndication information model.This root concept contains all data elements of the MedicationContraIndication information model. |
|
|||||||||||
NL-CM:9.14.2 | StartDateTime | 0..1 | The date and possibly time when the contraindication for medication was identified. |
|
||||||||||
NL-CM:9.14.3 | EndDateTime | 0..1 | The date and, if applicable, time when the contraindication for medication monitoring is considered no longer applicable. |
|
||||||||||
NL-CM:9.14.4 | ReasonClosure | 0..1 | Reason for closing the medication contraindication. |
|
||||||||||
NL-CM:9.14.5 | Reporter::HealthProfessional | 1 | The health professional who takes responsibility for registering the contraindication. |
| ||||||||||
NL-CM:9.14.6 | MedicationContraIndicationName | 1 | The name and code of the contraindication from the Dutch National Contraindication list (G-standard Thesaurus 40). |
|
| |||||||||
NL-CM:9.14.7 | Comment | 0..1 | Comment on the contraindication important for interpretation which cannot be captured in any of the other data items. For example, a comment on a contraindication with an end date in the future. |
|
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
MedicatieContraIndicatie | |||||||
Contra Indicatie | BeginDatum | EindDatum | Reden van Afsluiten | Toelichting | Zorgverlener::Melder | ||
Naam | Specialisme | Zorgaanbieder | |||||
(1320) Zwangerschap |
08-06-2020 | 08-03-2021 | D. Bakker | Huisarts | Huisartsenpraktijk Bakker | ||
(0210) Sportbeoefening |
01-08-2015 | Handboogschieten | K. Vriendwijk | Huisarts | Huisartsenpraktijk ‘t Zonnetje | ||
(113) Morbide obesitas |
31-12-2016 | 21-09-2019 | Heeft gewicht verloren | T. de Groot | Huisarts | Zorginstelling De beste zorg | |
(1355) Bariatrische chirurgie |
10-04-2019 | L. de Jong | Chirurg | Ziekenhuis Kwaliteit en Veiligheid |
Instructions
In the G-standard Thesaurus 40, Z-Index uses 2 terms.
- The contraindication nature: the list of items referred to from MedicationContraIndicationName and
- the contraindication: the combination of recorded contraindication nature + the medicine (the contraindication codes from file 655).
This last combination between contraindication nature and medication is made via this MedicationContraIndication HCIM and one or more of the other medication HCIMs. For example in a medication process use-case ePrescription and/or dispense of medication.
References
1. Medicatiebewaking [online] beschikbaar op https://www.z-index.nl/documentatie [Geraadpleegd: 19 juni 2020]
Valuesets
MedicationContraIndicationNameCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.9.14.1 | Binding: Required |
Conceptname | Codesystem name | Codesystem OID |
alle waarden | G-standaard Contra Indicaties (Thesaurus 40) | 2.16.840.1.113883.2.4.4.1.902.40 |
This information model in other releases
- Release 2020, (Version 1.0)
- Prerelease 2021-2, (Version 1.1)
- Prerelease 2022-1, (Version 2.0)
- Prerelease 2024-1, (Version 2.0.1)
Information model references
This information model refers to
This information model is used in
- --
Technical specifications in HL7v3 CDA and HL7 FHIR
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
- HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
- HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
Downloads
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Prerelease 2023-1
SNOMED CT and LOINC codes are based on:
- SNOMED Clinical Terms versie: 20230930 [R] (september 2023-editie)
- LOINC version 2.76
Conditions for use are located on the mainpage
This page is generated on 31/10/2023 18:34:58 with ZibExtraction v. 9.3.8704.31782