HeartRate-v3.1(2017EN): verschil tussen versies

Uit Zorginformatiebouwstenen
Naar navigatie springen Naar zoeken springen
(Copy of)
Geen bewerkingssamenvatting
Regel 1: Regel 1:
==General information==
<!-- Hieronder wordt een transclude page aangeroepen -->
Name: '''nl.zorg.HeartRate''' [[Bestand:NL.png|link=Hartfrequentie-v3.1(2017NL)]]<BR>
{{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.12.3(EN)|1|HeartRate-v3.1(2017EN)}}
Version: '''3.1''' <br>
<!-- Tot hier de transclude page -->
HCIM Status:Final<br>
==General information<!--hdGeneralInformation-->==
Release: '''2017''' <br>
Name<!--hdName-->: '''nl.zorg.HeartRate''' [[Bestand:NL.png|link=Hartfrequentie-v3.1(2017NL)]]<BR>
Release status: Published<br>
Version<!--hdVersion-->: '''3.1''' <br>
Release date: 31-12-2017
HCIM Status<!--hdStatus-->:Final<br>
Release<!--hdPublication-->: '''2017''' <br>
Release status<!--hdPublicationStatus-->: Published<br>
Release date<!--hdPublicationDate-->: 31-12-2017
-----
-----
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release_2017(EN)]] [[HCIM_Release_2017(EN) |Back to HCIM list ]]</div>
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2017(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2017(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div>


==Metadata==
==Metadata==
Regel 61: Regel 64:
==Revision History==
==Revision History==
<div class="mw-collapsible mw-collapsed">
<div class="mw-collapsible mw-collapsed">
''Only available in Dutch''
''Only available in Dutch<!--noTranslation-->''


<u>Publicatieversie 1.0</u> (15-02-2013)
<u>Publicatieversie 1.0</u> (15-02-2013)
Regel 138: Regel 141:
<BR>
<BR>
<imagemap> Bestand:HeartRate-v3.1Model(EN).png | center  
<imagemap> Bestand:HeartRate-v3.1Model(EN).png | center  
rect 195 453 368 503 [[#HeartRateMeasurementMethodCodelist]]
rect 205 461 378 511 [[#HeartRateMeasurementMethodCodelist]]
rect 212 331 348 401 [[#9392]]
rect 222 339 358 409 [[#9392]]
rect 392 452 582 502 [[#HeartbeatRegularityCodelist]]
rect 402 460 592 510 [[#HeartbeatRegularityCodelist]]
rect 413 330 559 400 [[#9394]]
rect 423 338 569 408 [[#9394]]
rect 508 204 598 274 [[#9393]]
rect 518 212 608 282 [[#9393]]
rect 339 77 453 147 [[#9390]]
rect 349 85 463 155 [[#9390]]
rect 149 204 279 274 [[#9391]]
rect 159 212 289 282 [[#9391]]
rect 335 204 457 274 [[#9389]]
rect 345 212 467 282 [[#9389]]
desc none
desc none
</imagemap>
</imagemap>
Regel 151: Regel 154:
{| border= "1"  width="1500px" style = "font-size: 9.5pt;  border: solid 1px silver; border-collapse:collapse;" cellpadding = "3px" cellspacing ="0px"  
{| border= "1"  width="1500px" style = "font-size: 9.5pt;  border: solid 1px silver; border-collapse:collapse;" cellpadding = "3px" cellspacing ="0px"  
|-style="background-color: #1F497D; color: white; font-weight: bold; font-variant: small-caps; "
|-style="background-color: #1F497D; color: white; font-weight: bold; font-variant: small-caps; "
|style="width:30px;"|Type||style="width:100px;"|Id||colspan="6 " style="width:140px;"|Concept||Card.||style="width: 600px;"|Definition||style="width:200px;"|DefinitionCode||style="width:200px;"|Reference
|style="width:30px;"|Type<!--imType-->||style="width:100px;"|Id<!--imId-->||colspan="6 " style="width:140px;"|Concept<!--imConcept-->||Card.<!--imCard-->||style="width: 600px;"|Definition<!--imDefinition-->||style="width:200px;"|DefinitionCode<!--imDefinitionCode-->||style="width:200px;"|Reference<!--imReference-->
|-style="vertical-align:top; background-color: #E3E3E3; "
|-style="vertical-align:top; background-color: #E3E3E3; "
|style = "text-align:center" |[[Bestand: block.png| 20px | link=]]
|style = "text-align:center" |[[Bestand: block.png| 20px | link=]]
Regel 170: Regel 173:
{|
{|
|-
|-
|<span Title="Codesystem: LOINC"> 8867-4 Heart Rate </span>
|<span title = "Codesystem: LOINC>[https://terminologie.nictiz.nl/art-decor/loinc?conceptId=8867-4 8867-4] Heart Rate</span>
|}
|}
|
|
Regel 205: Regel 208:
{|
{|
|-
|-
|<span Title="Codesystem: LOINC"> 48767-8 Annotation comment</span>
|<span title = "Codesystem: LOINC>[https://terminologie.nictiz.nl/art-decor/loinc?conceptId=48767-8 48767-8] Annotation comment</span>
|}
|}
|
|
Regel 222: Regel 225:
|}
|}
|}
|}
Columns Concept and DefinitionCode: hover over the values for more information<BR>
Columns Concept and DefinitionCode: hover over the values for more information<!--imHover--><BR>
For explanation of the symbols, please see the legend page [[Bestand:list2.png|link=Legend]]
For explanation of the symbols, please see the legend page<!--imLegend--> [[Bestand:list2.png|link=Legend<!--wikiLegend-->]]


==Example Instances==
==Example Instances==
''Only available in Dutch''
''Only available in Dutch<!--noTranslation-->''


{|class="wikitable" width="700px" style= "font-size: 9.5pt;"
{|class="wikitable" width="700px" style= "font-size: 9.5pt;"
Regel 254: Regel 257:
{| class="wikitable" width="60%"  
{| class="wikitable" width="60%"  
|-style='vertical-align:top; background-color: #E8D7BE;'
|-style='vertical-align:top; background-color: #E8D7BE;'
|Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.12.3.1
|Valueset OID<!--vsValuesetOID-->: 2.16.840.1.113883.2.4.3.11.60.40.2.12.3.1
|Binding<!--vsBindingTag-->:
|}
|}
{| class="wikitable"  width="60% "
{| class="wikitable"  width="60% "
|-style="background-color: #1F497D; color: white; font-weight: bold; "
|-style="background-color: #1F497D; color: white; font-weight: bold; "
|Conceptname
|Conceptname<!--vsConceptName-->
|Conceptcode
|Conceptcode<!--vsConceptCode-->
|Codesystem name||Codesystem OID
|Codesystem name<!--vsConceptSystemName-->||Codesystem OID<!--vsConceptSystemOID-->
|Description
|Description<!--vsDescription-->
|-style="vertical-align:top; "
|-style="vertical-align:top; "
|Heart regular
|Heart regular
|271636001
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=271636001 271636001]
|SNOMED CT
|SNOMED CT
|2.16.840.1.113883.6.96
|2.16.840.1.113883.6.96
Regel 270: Regel 274:
|-style="vertical-align:top; "
|-style="vertical-align:top; "
|Heart irregular
|Heart irregular
|248650006
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=248650006 248650006]
|SNOMED CT
|SNOMED CT
|2.16.840.1.113883.6.96
|2.16.840.1.113883.6.96
|Hartslag onregelmatig
|Hartslag onregelmatig
|}
|}
=== HeartRateMeasurementMethodCodelist===
=== HeartRateMeasurementMethodCodelist===
{| class="wikitable" width="60%"  
{| class="wikitable" width="60%"  
|-style='vertical-align:top; background-color: #E8D7BE;'
|-style='vertical-align:top; background-color: #E8D7BE;'
|Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.12.3.2
|Valueset OID<!--vsValuesetOID-->: 2.16.840.1.113883.2.4.3.11.60.40.2.12.3.2
|Binding<!--vsBindingTag-->:
|}
|}
{| class="wikitable"  width="60% "
{| class="wikitable"  width="60% "
|-style="background-color: #1F497D; color: white; font-weight: bold; "
|-style="background-color: #1F497D; color: white; font-weight: bold; "
|Conceptname
|Conceptname<!--vsConceptName-->
|Conceptcode
|Conceptcode<!--vsConceptCode-->
|Codesystem name||Codesystem OID
|Codesystem name<!--vsConceptSystemName-->||Codesystem OID<!--vsConceptSystemOID-->
|Description
|Description<!--vsDescription-->
|-style="vertical-align:top; "
|-style="vertical-align:top; "
|Palpation
|Palpation
|113011001
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=113011001 113011001]
|SNOMED CT
|SNOMED CT
|2.16.840.1.113883.6.96
|2.16.840.1.113883.6.96
Regel 295: Regel 299:
|-style="vertical-align:top; "
|-style="vertical-align:top; "
|Auscultation
|Auscultation
|37931006
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=37931006 37931006]
|SNOMED CT
|SNOMED CT
|2.16.840.1.113883.6.96
|2.16.840.1.113883.6.96
Regel 301: Regel 305:
|-style="vertical-align:top; "
|-style="vertical-align:top; "
|Cardiac monitoring
|Cardiac monitoring
|88140007
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=88140007 88140007]
|SNOMED CT
|SNOMED CT
|2.16.840.1.113883.6.96
|2.16.840.1.113883.6.96
Regel 307: Regel 311:
|-style="vertical-align:top; "
|-style="vertical-align:top; "
|ECG
|ECG
|46825001
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=46825001 46825001]
|SNOMED CT
|SNOMED CT
|2.16.840.1.113883.6.96
|2.16.840.1.113883.6.96
Regel 313: Regel 317:
|}
|}


 
==This information model in other releases<!--ftOtherReleases-->==
==This information model in other releases==
<!-- Hieronder wordt een transclude page aangeroepen -->
<ul>
{{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.12.3(EN)|2|2017}}
<li>[[HeartRate-v1.2(2015EN) | Release 2015, (Version 1.2)]]</li>
<!-- Tot hier de transclude page -->
<li>[[HeartRate-v3.0(2016EN) | Release 2016, (Version 3.0)]]</li>
==Information model references<!--ftReferences-->==
</ul>
====This information model refers to<!--ftRefersTo-->====
==More on this information model==
:--
====This information model is used in<!--ftReferredBy-->====
:--
==Technical specifications in HL7v3 CDA and HL7 FHIR<!--ftHeader-->==
To exchange information based on health and care information models, additional, more technical specifications are required.<BR>
To exchange information based on health and care information models, additional, more technical specifications are required.<BR>
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro-->
<ul>
<ul>
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2017bbr-?id=2.16.840.1.113883.2.4.3.11.60.7.4.2.12.3&effectiveDate=2017-12-31T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li>
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2017bbr-?id=2.16.840.1.113883.2.4.3.11.60.7.4.2.12.3&effectiveDate=2017-12-31T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li>
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR [https://simplifier.net/NictizSTU3/~resources?text=zib&category=Profile [[File:fhir.png|link=]]]</li>
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2017}}</li>
</ul>
</ul>
This information model is also available as [[Media:nl.zorg.HeartRate-v3.1(2017EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.zorg.HeartRate-v3.1(2017EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]
==Downloads<!--ftDownloadTitle-->==
==About this information==
This information model is also available as [[Media:nl.zorg.HeartRate-v3.1(2017EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.zorg.HeartRate-v3.1(2017EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]<!--ftDownloads-->
The information in this wikipage is based on Release 2017 <BR>
==About this information<!--ftHeader2-->==
Conditions for use are located on the mainpage [[Bestand:list2.png|link=HCIM_Mainpage]]<BR>
The information in this wikipage is based on<!--ftInfoBase--> Release 2017 <BR>
This page is generated on 24/01/2018 15:57:31 <BR>
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR>
This page is generated on 19/12/2018 18:31:54 with ZibExtraction v. 3.0.6927.32850<!--ftDate--> <BR>
-----
-----
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release_2017(EN)]] [[HCIM_Release_2017(EN) |Back to HCIM list ]]</div>
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2017(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2017(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div>

Versie van 20 dec 2018 13:31


Attention!! This is not the most recent version of this information model. You can find the most recent version ''here''.

General information

Name: nl.zorg.HeartRate NL.png
Version: 3.1
HCIM Status:Final
Release: 2017
Release status: Published
Release date: 31-12-2017


Back 16.png Back to HCIM list

Metadata

DCM::CoderList Kerngroep Registratie aan de Bron
DCM::ContactInformation.Address *
DCM::ContactInformation.Name *
DCM::ContactInformation.Telecom *
DCM::ContentAuthorList Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron
DCM::CreationDate 29-11-2012
DCM::DeprecatedDate
DCM::DescriptionLanguage nl
DCM::EndorsingAuthority.Address
DCM::EndorsingAuthority.Name PM
DCM::EndorsingAuthority.Telecom
DCM::Id 2.16.840.1.113883.2.4.3.11.60.40.3.12.3
DCM::KeywordList hartfrequentie, vitale parameters, hartslag
DCM::LifecycleStatus Final
DCM::ModelerList Kerngroep Registratie aan de Bron
DCM::Name nl.zorg.Hartfrequentie
DCM::PublicationDate 31-12-2017
DCM::PublicationStatus Published
DCM::ReviewerList Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron
DCM::RevisionDate 31-12-2017
DCM::Superseeds nl.zorg.Hartfrequentie-v3.0
DCM::Version 3.1
HCIM::PublicationLanguage EN

Revision History

Only available in Dutch

Publicatieversie 1.0 (15-02-2013)

Publicatieversie 1.1 (01-07-2013)

Publicatieversie 1.2 (01-04-2015)

ZIB-141 Aanpassingen in SNOMED CT codes en omschrijvingen voor codelijst HartslagMethodeCodelijst n.a.v. review terminologie expert.
ZIB-234 HartMethodeCodelijst bevat een typefout, namelijk aplation i.p.v. Palpation.
ZIB-308 Prefix Overdracht weggehaald bij de generieke bouwstenen
ZIB-360 Palpatie als hartslagmethode in hartfrequentie

Incl. algemene wijzigingsverzoeken:

ZIB-94 Aanpassen tekst van Disclaimer, Terms of Use & Copyrights
ZIB-154 Consequenties opsplitsing Medicatie bouwstenen voor overige bouwstenen.
ZIB-200 Naamgeving SNOMED CT in tagged values klinische bouwstenen gelijk getrokken.
ZIB-201 Naamgeving OID: in tagged value notes van klinische bouwstenen gelijk getrokken.
ZIB-309 EOI aangepast
ZIB-324 Codelijsten Name en Description beginnen met een Hoofdletter
ZIB-326 Tekstuele aanpassingen conform de kwaliteitsreview kerngroep 2015

Publicatieversie 3.0 (01-05-2016)

Publicatieversie 3.1 (04-09-2017)

ZIB-431 Gebruik van LOINC en SNOMED CT in vitale functies gerelateerde zorginformatiebouwstenen
ZIB-549 De Engelse naam van de bouwsteen en het rootconcept zijn niet correct
ZIB-564 Aanpassing/harmonisatie Engelse conceptnamen

Concept

The heart rate is the number of heartbeats per minute.

Purpose

Obtaining information on circulation and heart function by measuring the heartrate.

Evidence Base

Heart rate (electric or auscultatory rhythm of the ventricles) and pulse rate (tangible output in the peripheral arteries) are physiologically different things, but produce the same values in normal circulation (beats per minute) and are therefore used interchangeably by many healthcare providers (and laymen). This is however incorrect, as a patient’s pulse rate can be lower than their heart rate. Nevertheless, in daily practice, the pulse is usually palpated to measure heart rate and also written down as the heart rate. For this reason, the HeartRate information model, in addition to the PulseRate information model, offers the option to enter palpation as the HeartRateMeasurementMethod.

Information Model


#HeartRateMeasurementMethodCodelist#9392#HeartbeatRegularityCodelist#9394#9393#9390#9391#9389HeartRate-v3.1Model(EN).png


Type Id Concept Card. Definition DefinitionCode Reference
Block.png NL-CM:12.3.1 Arrowdown.pngHeartRate Root concept of the HeartRate information model. This root concept contains all data elements of the HeartRate information model.
PQ.png NL-CM:12.3.2 Arrowright.pngHeartRateValue 1 The heart rate measured as the number of heartbeats per minute.
8867-4 Heart Rate
TS.png NL-CM:12.3.4 Arrowright.pngHeartRateDateTime 1 Date and time of the heart rate measurement.
CD.png NL-CM:12.3.6 Arrowright.pngHeartRateMeasurementMethod 0..1 The method used to count and observe the heart rate.
List2.png HeartRateMeasurementMethodCodelist
ST.png NL-CM:12.3.3 Arrowright.pngComment 0..1 Comment on any problems or factors that may influence the measurement. Further explanation can be provided here as well.
48767-8 Annotation comment
CD.png NL-CM:12.3.5 Arrowright.pngHeartbeatRegularity 0..1 Regularity of the heartbeat.
List2.png HeartbeatRegularityCodelist

Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page List2.png

Example Instances

Only available in Dutch

HartfrequentieDatumTijd HartfrequentieWaarde HartslagMeet
Methode
Hartslag
Regelmatigheid
Toelichting
08-02-2013 6:43 126/min Auscultatie Hartslag onregelmatig Misschien bigeminie?

Instructions

A Holter registration is a 24-hour ECG: an ECG with a very long measuring period.

References

1. Parelsnoer DCM Hartslag v0.98. [Online] Beschikbaar op: http://www.nictiz.nl/uploaded/FILES/htmlcontent/dcm/parelsnoer/Hartslag%20v0.64.pdf [Geraadpleegd: 19 februari 2015]. 2. openEHR-EHR-OBSERVATION.heart_rate.v1 [Online] Beschikbaar op: http://www.openehr.org/knowledge/ [Geraadpleegd: 19 februari 2015].

Valuesets

HeartbeatRegularityCodelist

Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.3.1 Binding:
Conceptname Conceptcode Codesystem name Codesystem OID Description
Heart regular 271636001 SNOMED CT 2.16.840.1.113883.6.96 Hartslag regelmatig
Heart irregular 248650006 SNOMED CT 2.16.840.1.113883.6.96 Hartslag onregelmatig

HeartRateMeasurementMethodCodelist

Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.3.2 Binding:
Conceptname Conceptcode Codesystem name Codesystem OID Description
Palpation 113011001 SNOMED CT 2.16.840.1.113883.6.96 Palpatie
Auscultation 37931006 SNOMED CT 2.16.840.1.113883.6.96 Auscultatie
Cardiac monitoring 88140007 SNOMED CT 2.16.840.1.113883.6.96 Cardiale monitoring
ECG 46825001 SNOMED CT 2.16.840.1.113883.6.96 Electrocardiografie

This information model in other releases

Information model references

This information model refers to

--

This information model is used in

--

Technical specifications in HL7v3 CDA and HL7 FHIR

To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:

  • HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment Artdecor.jpg
  • HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR Fhir.png

Downloads

This information model is also available as pdf file PDF.png or as spreadsheet Xlsx.png

About this information

The information in this wikipage is based on Release 2017
Conditions for use are located on the mainpage List2.png
This page is generated on 19/12/2018 18:31:54 with ZibExtraction v. 3.0.6927.32850


Back 16.png Back to HCIM list