In de klinische bouwsteen OverdrachtZorgaanbieder DCM::ValueSet AGB (de (Vektis) AGB-Z code) van concept ZorgaanbiederIdentificatieNummer aangepast in DCM::AssigningAuthority tagged value, incl. OID in tagged value notes.
In de klinische bouwsteen OverdrachtZorgaanbieder DCM::ValueSet URA (Het CIBG UZI-Register-Abonneenummer) van concept ZorgaanbiederIdentificatieNummer aangepast in DCM::AssigningAuthority tagged value, incl. OID in tagged value notes.
A healthcare provider is an organization that offers and provides medical, paramedic and/or nursing care to patients/clients. Examples include: hospitals, nursing homes, doctor’s offices.
Purpose
Recording relevant information to identify the organization for administrative purposes.
Information Model
Type
Id
Concept
Card.
Definition
DefinitionCode
Reference
NL-CM:17.2.1
HealthcareProvider
Root concept of the Healthcare Provider information model. This root concept contains all data elements of the Healthcare Provider information model.
NL-CM:17.2.2
HealthcareProviderIdentificationNumber
0..*
The organization’s identification number. For Dutch healthcare providers, the URA number or the AGB number is used, if possible. Depending on the context other ID's are also possible. For foreign or non-affiliated healthcare providers, another unique identification number can be used. This must be accompanied by the name and/or code of the issuing organization.
Name of the organization. If an identification number is given, the name must match the name that corresponds to the identification number.
NL-CM:17.2.8
OrganizationLocation
0..1
Name of the location, in case a healthcare organization has more than one location.
NL-CM:17.2.7
DepartmentSpecialty
0..1
The specialty of the healthcare provider’s department. The departmental specialty can be filled in if further indication of the healthcare provider is needed. This refers to the recognized medical specialties as stated in the BIG Act.
The type of healthcare provider, such as general hospital, or nursing home. If this field is filled in and an AGB code is used for the HealthcareProviderIdentificationNumber, the type must match the type implicitly contained in the AGB code.
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
The information in this wikipage is based on Prerelease 2017 #1
Conditions for use are located on the mainpage
This page is generated on 30/11/2017 13:38:44