AbilityToPerformNursingActivities-v1.0.2(2023EN): verschil tussen versies
Geen bewerkingssamenvatting |
Geen bewerkingssamenvatting |
||
Regel 54: | Regel 54: | ||
|style="width:250px; "|DCM::PublicationStatus||Prepublished | |style="width:250px; "|DCM::PublicationStatus||Prepublished | ||
|- | |- | ||
|style="width:250px; "|DCM::ReviewerList||Projectgroep RadB Verpleegkundige Gegevens & | |style="width:250px; "|DCM::ReviewerList||Projectgroep RadB Verpleegkundige Gegevens & Kerngroep Registratie aan de Bron | ||
|- | |- | ||
|style="width:250px; "|DCM::RevisionDate||12-09-2023 | |style="width:250px; "|DCM::RevisionDate||12-09-2023 | ||
Regel 224: | Regel 224: | ||
:-- | :-- | ||
==Technical specifications in HL7v3 CDA and HL7 FHIR<!--ftHeader-->== | ==Technical specifications in HL7v3 CDA and HL7 FHIR<!--ftHeader-->== | ||
To exchange information based on health and care information models, additional, more technical specifications are required. | To exchange information based on health and care information models, additional, more technical specifications are required.<BR> | ||
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro--> | Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro--> | ||
<ul> | <ul> | ||
<li> | <li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> {{ArtDecorLinks|2023|4.34}}</li> | ||
<li> | <li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2023|VermogenTotVerpleegtechnischeHandelingen}}</li> | ||
</ul> | </ul> | ||
==Downloads<!--ftDownloadTitle-->== | ==Downloads<!--ftDownloadTitle-->== | ||
Regel 240: | Regel 240: | ||
</ul> | </ul> | ||
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR> | Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR> | ||
This page is generated on | This page is generated on 31/10/2023 19:32:28 with ZibExtraction v. 9.3.8704.31782<!--ftDate--> <BR> | ||
----- | ----- | ||
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2023(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2023(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2023(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2023(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> |
Huidige versie van 31 okt 2023 om 19:59
General information
Name: nl.zorg.AbilityToPerformNursingActivities
Version: 1.0.2
HCIM Status:Final
Release: 2023
Release status: Prepublished
Release date: 15-10-2023
Metadata
DCM::CoderList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::ContactInformation.Address | * |
DCM::ContactInformation.Name | * |
DCM::ContactInformation.Telecom | * |
DCM::ContentAuthorList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::CreationDate | 19-11-2016 |
DCM::DeprecatedDate | |
DCM::DescriptionLanguage | nl |
DCM::EndorsingAuthority.Address | |
DCM::EndorsingAuthority.Name | PM |
DCM::EndorsingAuthority.Telecom | |
DCM::Id | 2.16.840.1.113883.2.4.3.11.60.40.3.4.34 |
DCM::KeywordList | IADL, |
DCM::LifecycleStatus | Final |
DCM::ModelerList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::Name | nl.zorg.VermogenTotVerpleegtechnischeHandelingen |
DCM::PublicationDate | 15-10-2023 |
DCM::PublicationStatus | Prepublished |
DCM::ReviewerList | Projectgroep RadB Verpleegkundige Gegevens & Kerngroep Registratie aan de Bron |
DCM::RevisionDate | 12-09-2023 |
DCM::Supersedes | nl.zorg.VermogenTotVerpleegtechnischeHandelingen-v1.0.1 |
DCM::Version | 1.0.2 |
HCIM::PublicationLanguage | EN |
Revision History
Only available in Dutch
Publicatieversie 1.0 (04-09-2017)
Publicatieversie 1.0.1 (01-09-2020)
ZIB-1115 | Serie zibs vermogen tot datatype CO klopt niet |
Publicatieversie 1.0.2 (15-10-2023)
ZIB-1853 | Bij Example of the instrument staat foutief Betrokkene::Contactpersoon |
Concept
When taking care of a patient with a disease or disability, parents, children and other caretakers often carry out nursing interventions. Adults and older children may carry out nursing interventions by themselves. Therefore skills training is needed for caregivers/ children. Qualification is required for correct performing of an intervention and also knowledge about what to do in case of complications.
The assessment of the degree to which the intervention can be performed independently refers only to the indicated intervention.
Purpose
Information about the qualification of skill for performing a specific nursing intervention is necessary to provide parents, children and other caregivers appropriate support for the care of the patient.
Evidence Base
To indicate to whom the defined skill relates, the performer from the NursingIntervention HCIM is used. If the performer element from the NursingIntervention HCIM is not used, the defined skill refers to the patient.
Information Model
Type | Id | Concept | Card. | Definition | DefinitionCode | Reference | ||||||||
NL-CM:4.34.1 | AbilityToPerformNursingActivities | Root concept of the AbilityToPerformNursingActivities information model. This root concept contains all data elements of the AbilityToPerformNursingActivities information model. | ||||||||||||
NL-CM:4.34.3 | NursingIntervention | 1 | Specification of nursing interventions where the skills relate to. |
| ||||||||||
NL-CM:4.34.2 | PerformNursingActivity | 1 | Qualification of the degree of independence when performing certain (nursing) interventions. |
|
|
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
VermogenTotVerpleegkundigeHandelingen | |
MateVanBekwaamheid | Met hulp |
Betrokkene::ContactPersoon | |
Relatie | Moeder |
VerpleegkundigeActie | |
Activiteit | Katheteriseren |
Startdatum | 18-12-2016 |
Frequentie | 3 maal daags |
Toelichting | Toezicht bij uitvoer, en instructie hygiënisch werken |
Valuesets
PerformNursingActivityCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.4.34.1 | Binding: Required |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
Independent in managing personal healthcare | 27911000146108 | SNOMED CT | 2.16.840.1.113883.6.96 | Onafhankelijk |
Needs help with managing personal healthcare | 27931000146101 | SNOMED CT | 2.16.840.1.113883.6.96 | Hulp nodig |
Unable to manage personal healthcare | 27951000146107 | SNOMED CT | 2.16.840.1.113883.6.96 | Volledig afhankelijk |
This information model in other releases
- Release 2017, (Version 1.0)
- Prerelease 2018-2, (Version 1.0)
- Prerelease 2019-2, (Version 1.0)
- Release 2020, (Version 1.0.1)
- Prerelease 2021-2, (Version 1.0.1)
- Prerelease 2022-1, (Version 1.0.1)
- Prerelease 2024-1, (Version 1.0.2)
Information model references
This information model refers to
This information model is used in
- --
Technical specifications in HL7v3 CDA and HL7 FHIR
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
- HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
- HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
Downloads
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Prerelease 2023-1
SNOMED CT and LOINC codes are based on:
- SNOMED Clinical Terms versie: 20230930 [R] (september 2023-editie)
- LOINC version 2.76
Conditions for use are located on the mainpage
This page is generated on 31/10/2023 19:32:28 with ZibExtraction v. 9.3.8704.31782