VisualAcuity-v1.0(2020EN): verschil tussen versies
(Nieuwe pagina aangemaakt met '<!-- Hieronder wordt een transclude page aangeroepen --> {{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.12.19(EN)|1|VisualAcuity-v1.0(2020EN)}} <!-- Tot hier de tr...') |
Geen bewerkingssamenvatting |
||
(Een tussenliggende versie door dezelfde gebruiker niet weergegeven) | |||
Regel 9: | Regel 9: | ||
Release status<!--hdPublicationStatus-->: Published<br> | Release status<!--hdPublicationStatus-->: Published<br> | ||
Release date<!--hdPublicationDate-->: 01-09-2020 | Release date<!--hdPublicationDate-->: 01-09-2020 | ||
<!-- Aanroep Errata transclude page --> | |||
{{ErrataEN<!--hdErrata-->|2020|{{PAGENAME}}}} | |||
<!-- tot hier --> | |||
----- | ----- | ||
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2020(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2020(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2020(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2020(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> | ||
Regel 110: | Regel 113: | ||
{| | {| | ||
|- | |- | ||
|<span title = "Codesystem: SNOMED CT; Onderzoek van | |<span title = "Codesystem: SNOMED CT; Onderzoek van visus (procedure)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=16830007 16830007] Visual acuity testing</span> | ||
|} | |} | ||
| | | | ||
Regel 140: | Regel 143: | ||
{| | {| | ||
|- | |- | ||
|<span title = "Codesystem: SNOMED CT (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=363983007 363983007] Visual acuity</span> | |<span title = "Codesystem: SNOMED CT; Visus (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=363983007 363983007] Visual acuity</span> | ||
|} | |} | ||
| | | | ||
Regel 183: | Regel 186: | ||
{| | {| | ||
|- | |- | ||
|<span title = "Codesystem: SNOMED CT (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=363983007 363983007] Visual acuity</span> | |<span title = "Codesystem: SNOMED CT; Visus (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=363983007 363983007] Visual acuity</span> | ||
|} | |} | ||
| | | | ||
Regel 372: | Regel 375: | ||
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro--> | Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro--> | ||
<ul> | <ul> | ||
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2020bbr-?id=2.16.840.1.113883.2.4.3.11.60. | <li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2020bbr-?id=2.16.840.1.113883.2.4.3.11.60.121.4.2.12.19&effectiveDate=2020-09-01T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li> | ||
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2020}}</li> | <li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2020}}</li> | ||
</ul> | </ul> | ||
Regel 381: | Regel 384: | ||
SNOMED CT and LOINC codes are based on: | SNOMED CT and LOINC codes are based on: | ||
<ul> | <ul> | ||
<li>SNOMED Clinical Terms version: | <li>SNOMED Clinical Terms version: 20200731 [R] (July 2020 Release)</li> | ||
<li>LOINC version 2.67</li> | <li>LOINC version 2.67</li> | ||
</ul> | </ul> | ||
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR> | Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR> | ||
This page is generated on | This page is generated on 29/09/2020 21:25:01 with ZibExtraction v. 4.0.7577.31095<!--ftDate--> <BR> | ||
----- | ----- | ||
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2020(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2020(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2020(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2020(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> |
Huidige versie van 26 okt 2023 om 13:58
General information
Name: nl.zorg.VisualAcuity
Version: 1.0
HCIM Status:Final
Release: 2020
Release status: Published
Release date: 01-09-2020
Attention!! For this HCIM an erratum exists. You can find it in the Errata section of the release.
Metadata
DCM::CoderList | * |
DCM::ContactInformation.Address | * |
DCM::ContactInformation.Name | * |
DCM::ContactInformation.Telecom | * |
DCM::ContentAuthorList | * |
DCM::CreationDate | 15/06/2020 |
DCM::DeprecatedDate | |
DCM::DescriptionLanguage | nl |
DCM::EndorsingAuthority.Address | |
DCM::EndorsingAuthority.Name | * |
DCM::EndorsingAuthority.Telecom | |
DCM::Id | 2.16.840.1.113883.2.4.3.11.60.40.3.12.19 |
DCM::KeywordList | |
DCM::LifecycleStatus | Final |
DCM::ModelerList | * |
DCM::Name | nl.zorg.Visus |
DCM::PublicationDate | 01-09-2020 |
DCM::PublicationStatus | Published |
DCM::ReviewerList | |
DCM::RevisionDate | |
DCM::Supersedes | * |
DCM::Version | 1.0 |
HCIM::PublicationLanguage | EN |
Revision History
Only available in Dutch
Publicatieversie 1.0 (01-09-2020).
Concept
Visual acuity is a measurement of sharpness of vision. It is a measure of the smallest details that someone can still distinguish.
Purpose
The aim is to determine the patient's visual functioning based ontheir visual acuity.
Evidence Base
Patient Population
Adults and children from the age that they can interpret a picture chart.
Information Model
Type | Id | Concept | Card. | Definition | DefinitionCode | Reference | ||||||||
NL-CM:12.19.1 | VisualAcuity | Root concept of the VisualAcuity information model.This root concept contains all data elements of the VisualAcuity information model. |
|
|||||||||||
NL-CM:12.19.6 | VisualAcuityMeasurementDevice | 0..1 | The device used measuring the visual acuity. |
|
| |||||||||
NL-CM:12.19.2 | VisualAcuityType | 0..1 | Type of visual acuity measurment. |
|
| |||||||||
NL-CM:12.19.7 | VisualAcuityMeasurementChart | 0..1 | The type of chart used for the visual acuity measurement. |
|
| |||||||||
NL-CM:12.19.8 | DistanceFromChart | 0..1 | Distance to the chart in meters | |||||||||||
NL-CM:12.19.11 | DecimalVisualAqcuity | 0..1 | The measured decimal visual acuity. |
|
||||||||||
NL-CM:12.19.4 | VisualAcuityDateTime | 0..1 | The date and time when the visual acuity was measured. |
|
||||||||||
NL-CM:12.19.5 | AnatomicalLocation | 0..1 | The laterality of the eye of which the visual acuity has been measured. |
|
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
Visus | ||||||
DatumTijd | MetingType | Decimale Visus | Meting Kaart |
Afstand tot kaart | Lateraliteit | Meethulpmiddel |
08-02-2020 | Best gecorrigeerde visus | 0.8 | Snellen Letterkaart | 5 meter | Links | |
08-02-2020 | Gecorrigeerde visus | 1.0 | logaritmische E-hakenkaart | 3 meter | Rechts | Met stenopeische opening |
Traceability to other Standards
This health and care information model is based on the information model template Measurement- v1.0.
Valuesets
VisualAcuityMeasurementChartCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.19.3 | Binding: Extensible |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
Logarithmic E chart | 1 | VisusMeetkaart | 2.16.840.1.113883.2.4.3.11.60.40.4.27 | logaritmische E-hakenkaart |
Snellen chart | 2 | VisusMeetkaart | 2.16.840.1.113883.2.4.3.11.60.40.4.27 | Snellen Letterkaart |
LEA Hayvarinen chart | 3 | VisusMeetkaart | 2.16.840.1.113883.2.4.3.11.60.40.4.27 | LEA symbolen kaart |
Other | OTH | NullFlavor | 2.16.840.1.113883.5.1008 | Anders |
VisualAcuityMeasurementDeviceCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.19.4 | Binding: Extensible |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
Pinhole visual acuity | 419475002 | SNOMED CT | 2.16.840.1.113883.6.96 | Met stenopeïsche opening |
Other, specify | OTH | NullFlavor | 2.16.840.1.113883.5.1008 | Anders, specifieer |
VisusAcuityTypeCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.19.2 | Binding: Extensible |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
Corrected visual acuity | 397536007 | SNOMED CT | 2.16.840.1.113883.6.96 | Gecorrigeerde visus (met eigen bril) |
Uncorrected visual acuity | 420050001 | SNOMED CT | 2.16.840.1.113883.6.96 | Ongecorrigeerde visus |
Best corrected visual acuity | 419775003 | SNOMED CT | 2.16.840.1.113883.6.96 | Best gecorrigeerde visus(met optimale bril) |
Stereoscopic acuity | 359750002 | SNOMED CT | 2.16.840.1.113883.6.96 | Stereoscopische visus |
Other | OTH | NullFlavor | 2.16.840.1.113883.5.1008 | Anders, specificieer |
This information model in other releases
- Prerelease 2021-2, (Version 2.0)
- Prerelease 2022-1, (Version 2.1)
- Prerelease 2023-1, (Version 2.1.1)
- Prerelease 2024-1, (Version 2.1.1)
Information model references
This information model refers to
This information model is used in
- --
Technical specifications in HL7v3 CDA and HL7 FHIR
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
- HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
- HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
Downloads
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Release 2020
SNOMED CT and LOINC codes are based on:
- SNOMED Clinical Terms version: 20200731 [R] (July 2020 Release)
- LOINC version 2.67
Conditions for use are located on the mainpage