Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro-->
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro-->
<ul>
<ul>
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2020bbr-?id=2.16.840.1.113883.2.4.3.11.60.10.4.2.12.15&effectiveDate=2020-09-01T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li>
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2020bbr-?id=2.16.840.1.113883.2.4.3.11.60.121.4.2.12.15&effectiveDate=2020-09-01T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li>
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2020}}</li>
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2020}}</li>
</ul>
</ul>
Regel 226: Regel 226:
SNOMED CT and LOINC codes are based on:
SNOMED CT and LOINC codes are based on:
<ul>
<ul>
<li>SNOMED Clinical Terms version: 20200309 [R] (March 2020 Interim Release)</li>
<li>SNOMED Clinical Terms version: 20200731 [R] (July 2020 Release)</li>
<li>LOINC version 2.67</li>
<li>LOINC version 2.67</li>
</ul>
</ul>
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR>
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR>
This page is generated on 03/09/2020 12:56:03 with ZibExtraction v. 4.0.7551.21411<!--ftDate--> <BR>
This page is generated on 29/09/2020 21:09:15 with ZibExtraction v. 4.0.7577.31095<!--ftDate--> <BR>
-----
-----
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2020(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2020(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div>
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2020(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2020(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div>

Huidige versie van 29 sep 2020 om 21:18


Attention!! This is not the most recent version of this information model. You can find the most recent version ''here''.

General information

Name: nl.zorg.FluidBalance NL.png
Version: 1.0.1
HCIM Status:Final
Release: 2020
Release status: Published
Release date: 01-09-2020


Back 16.png Back to HCIM list

Metadata

DCM::CoderList Werkgroep RadB Verpleegkundige Gegevens
DCM::ContactInformation.Address *
DCM::ContactInformation.Name *
DCM::ContactInformation.Telecom *
DCM::ContentAuthorList Werkgroep RadB Verpleegkundige Gegevens
DCM::CreationDate 11-10-2016
DCM::DeprecatedDate
DCM::DescriptionLanguage nl
DCM::EndorsingAuthority.Address
DCM::EndorsingAuthority.Name
DCM::EndorsingAuthority.Telecom
DCM::Id 2.16.840.1.113883.2.4.3.11.60.40.3.12.15
DCM::KeywordList Vochtbalans
DCM::LifecycleStatus Final
DCM::ModelerList Werkgroep RadB Verpleegkundige Gegevens
DCM::Name nl.zorg.Vochtbalans
DCM::PublicationDate 01-09-2020
DCM::PublicationStatus Published
DCM::ReviewerList Projectgroep RadB Verpleegkundige Gegevens & Kerngroep Registratie aan de Bron
DCM::RevisionDate 28-08-2020
DCM::Supersedes nl.zorg.Vochtbalans-v1.0
DCM::Version 1.0.1
HCIM::PublicationLanguage EN

Revision History

Only available in Dutch

Publicatieversie 1.0 (04-09-2017)

Publicatieversie 1.0.1 (01-09-2020)

ZIB-1188 DefintionCodes zib nl.vochtbalans

Concept

The total water intake and water excretion within a certain time period: a disbalance can lead to for example dehydration or overfilling.

Purpose

Information about the water balance provides insight in the care plan for drinking and possibly administering extra fluids, when the balance is disrupted such as dehydration or overfilling.

Evidence Base

The definitions of the concepts were (partly) based on the guideline Dehydration by the VvOV.

Information Model


#12081#12086#12084#12082#12083#12085FluidBalance-v1.0.1Model(2020EN).png


Type Id Concept Card. Definition DefinitionCode Reference
Block.png NL-CM:12.15.1 Arrowdown.pngFluidBalance Root concept of the FluidBalance information model. This root concept contains all data elements of the FluidBalance information model.
710853006 Assessment of fluid balance
ST.png NL-CM:12.15.6 Arrowright.pngComment 0..1 Comment on the fluid balance.
48767-8 Annotation comment [Interpretation] Narrative
PQ.png NL-CM:12.15.4 Arrowright.pngFluidTotalIn 0..1 The total of fluid intake (e.g. by mouth, drip or tube feeding) in mL.
251852001 Total fluid input
PQ.png NL-CM:12.15.5 Arrowright.pngFluidTotalOut 0..1 The total of fluid excretion (e.g. urine production, drain, watery defecation) in mL.
251841007 Total fluid output
TS.png NL-CM:12.15.2 Arrowright.pngFluidBalanceStartTime 1 The time at which the measurement of the fluid balance was started.
442371002 Start time of procedure
TS.png NL-CM:12.15.3 Arrowright.pngFluidBalanceStopTime 1 The time at which the measurement of the fluid balance was stopped.
442137000 Completion time of procedure

Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page List2.png

Example Instances

Only available in Dutch

Vochtbalans
VochtTotaalIn 1400 ml
VochtTotaalUit 1000 ml
VochtbalansStarttijd 19-12-2016 0:00
VochtbalansStoptijd 20-12-2016 0:00
Toelichting -

This information model in other releases

Information model references

This information model refers to

--

This information model is used in

--

Technical specifications in HL7v3 CDA and HL7 FHIR

To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:

  • HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment Artdecor.jpg
  • HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR Fhir.png

Downloads

This information model is also available as pdf file PDF.png or as spreadsheet Xlsx.png

About this information

The information in this wikipage is based on Release 2020
SNOMED CT and LOINC codes are based on:

  • SNOMED Clinical Terms version: 20200731 [R] (July 2020 Release)
  • LOINC version 2.67

Conditions for use are located on the mainpage List2.png
This page is generated on 29/09/2020 21:09:15 with ZibExtraction v. 4.0.7577.31095


Back 16.png Back to HCIM list