HearingFunction-v3.2(2019EN): verschil tussen versies
(Nieuwe pagina aangemaakt met '<!-- Hieronder wordt een transclude page aangeroepen --> {{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.4.17(EN)|1|HearingFunction-v3.2(2019EN)}} <!-- Tot hier de...') |
Geen bewerkingssamenvatting |
||
Regel 8: | Regel 8: | ||
Release<!--hdPublication-->: '''2019''' <br> | Release<!--hdPublication-->: '''2019''' <br> | ||
Release status<!--hdPublicationStatus-->: Prepublished<br> | Release status<!--hdPublicationStatus-->: Prepublished<br> | ||
Release date<!--hdPublicationDate-->: | Release date<!--hdPublicationDate-->: 29-01-2020 | ||
----- | ----- | ||
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2019(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2019(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2019(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2019(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> | ||
Regel 47: | Regel 47: | ||
|style="width:250px; "|DCM::Name||nl.zorg.FunctieHoren | |style="width:250px; "|DCM::Name||nl.zorg.FunctieHoren | ||
|- | |- | ||
|style="width:250px; "|DCM::PublicationDate|| | |style="width:250px; "|DCM::PublicationDate||29-01-2020 | ||
|- | |- | ||
|style="width:250px; "|DCM::PublicationStatus||Prepublished | |style="width:250px; "|DCM::PublicationStatus||Prepublished | ||
Regel 55: | Regel 55: | ||
|style="width:250px; "|DCM::RevisionDate||16-05-2019 | |style="width:250px; "|DCM::RevisionDate||16-05-2019 | ||
|- | |- | ||
|style="width:250px; "|DCM:: | |style="width:250px; "|DCM::Supersedes||nl.zorg.FunctieHoren-v3.1 | ||
|- | |- | ||
|style="width:250px; "|DCM::Version||3.2 | |style="width:250px; "|DCM::Version||3.2 | ||
Regel 64: | Regel 64: | ||
==Revision History== | ==Revision History== | ||
<div class="mw-collapsible mw-collapsed"> | <div class="mw-collapsible mw-collapsed"> | ||
''Only available in Dutch<!--noTranslation-->'' | '' Only available in Dutch<!--noTranslation-->'' | ||
<u>Publicatieversie 1.0</u> (01-07-2015) | <u>Publicatieversie 1.0</u> (01-07-2015) | ||
Regel 70: | Regel 70: | ||
<u>Publicatieversie 3.0</u> (01-05-2016) | <u>Publicatieversie 3.0</u> (01-05-2016) | ||
{| | {| | ||
|- | |||
|style="width:75px; "|[[ZIBIssues#ZIB-453 | ZIB-453 ]] | |||
|Wijziging naamgeving ZIB's en logo's door andere opzet van beheer | |||
|} | |} | ||
Regel 77: | Regel 80: | ||
|style="width:75px; "|[[ZIBIssues#ZIB-530 | ZIB-530 ]] | |style="width:75px; "|[[ZIBIssues#ZIB-530 | ZIB-530 ]] | ||
|Verwijzingen naar de bouwsteen Verpleegkundige Interventie verwijderd | |Verwijzingen naar de bouwsteen Verpleegkundige Interventie verwijderd | ||
|- | |||
|style="width:75px; "|[[ZIBIssues#ZIB-531 | ZIB-531 ]] | |||
|Vervangen 5-punts ICF schaal door 3-punts SNOMED CT schaal voor beperkingen en stoornissen | |||
|} | |} | ||
Regel 336: | Regel 342: | ||
==Information model references<!--ftReferences-->== | ==Information model references<!--ftReferences-->== | ||
====This information model refers to<!--ftRefersTo-->==== | ====This information model refers to<!--ftRefersTo-->==== | ||
*[[MedicalDevice-v3.3(2019EN)|MedicalDevice-v3.3]] | |||
====This information model is used in<!--ftReferredBy-->==== | ====This information model is used in<!--ftReferredBy-->==== | ||
:-- | :-- | ||
Regel 343: | Regel 349: | ||
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro--> | Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro--> | ||
<ul> | <ul> | ||
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2019bbr-?id=2.16.840.1.113883.2.4.3.11.60.9.4.2.4.17&effectiveDate= | <li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2019bbr-?id=2.16.840.1.113883.2.4.3.11.60.9.4.2.4.17&effectiveDate=2020-01-29T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li> | ||
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2019}}</li> | <li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2019}}</li> | ||
</ul> | </ul> | ||
Regel 349: | Regel 355: | ||
This information model is also available as [[Media:nl.zorg.HearingFunction-v3.2(2019EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.zorg.HearingFunction-v3.2(2019EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]<!--ftDownloads--> | This information model is also available as [[Media:nl.zorg.HearingFunction-v3.2(2019EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.zorg.HearingFunction-v3.2(2019EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]<!--ftDownloads--> | ||
==About this information<!--ftHeader2-->== | ==About this information<!--ftHeader2-->== | ||
The information in this wikipage is based on<!--ftInfoBase--> Prerelease 2019- | The information in this wikipage is based on<!--ftInfoBase--> Prerelease 2019-2 <BR> | ||
SNOMED CT and LOINC codes are based on: | SNOMED CT and LOINC codes are based on: | ||
<ul> | <ul> | ||
<li>SNOMED Clinical Terms version: | <li>SNOMED Clinical Terms version: 20190731 [R] (July 2019 Release)</li> | ||
<li>LOINC version 2.64</li> | <li>LOINC version 2.64</li> | ||
</ul> | </ul> | ||
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR> | Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR> | ||
This page is generated on | This page is generated on 03/02/2020 01:26:38 with ZibExtraction v. 4.0.7338.2051<!--ftDate--> <BR> | ||
----- | ----- | ||
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2019(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2019(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2019(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2019(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> |
Huidige versie van 4 feb 2020 om 00:47
General information
Name: nl.zorg.HearingFunction
Version: 3.2
HCIM Status:Final
Release: 2019
Release status: Prepublished
Release date: 29-01-2020
Metadata
DCM::CoderList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::ContactInformation.Address | * |
DCM::ContactInformation.Name | * |
DCM::ContactInformation.Telecom | * |
DCM::ContentAuthorList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::CreationDate | 4-4-2014 |
DCM::DeprecatedDate | |
DCM::DescriptionLanguage | nl |
DCM::EndorsingAuthority.Address | |
DCM::EndorsingAuthority.Name | PM |
DCM::EndorsingAuthority.Telecom | |
DCM::Id | 2.16.840.1.113883.2.4.3.11.60.40.3.4.17 |
DCM::KeywordList | Horen, auditieve functies, gehoor |
DCM::LifecycleStatus | Final |
DCM::ModelerList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::Name | nl.zorg.FunctieHoren |
DCM::PublicationDate | 29-01-2020 |
DCM::PublicationStatus | Prepublished |
DCM::ReviewerList | Projectgroep RadB Verpleegkundige Gegevens & Kerngroep Registratie aan de Bron |
DCM::RevisionDate | 16-05-2019 |
DCM::Supersedes | nl.zorg.FunctieHoren-v3.1 |
DCM::Version | 3.2 |
HCIM::PublicationLanguage | EN |
Revision History
Only available in Dutch
Publicatieversie 1.0 (01-07-2015)
Publicatieversie 3.0 (01-05-2016)
ZIB-453 | Wijziging naamgeving ZIB's en logo's door andere opzet van beheer |
Publicatieversie 3.1 (04-09-2017)
ZIB-530 | Verwijzingen naar de bouwsteen Verpleegkundige Interventie verwijderd |
ZIB-531 | Vervangen 5-punts ICF schaal door 3-punts SNOMED CT schaal voor beperkingen en stoornissen |
Publicatieversie 3.2 (06-07-2019)
ZIB-732 | Een aantal Snomed codes blijken bij nadere controle invalide. Een aantal andere codes zijn inmiddels Inactive verklaard in SNOMED |
Concept
Hearing is the ability to observe sound, with the purpose of communicating with others, localizing the source of the sound and recognizing certain sounds. This pertains to observing the sound waves, and not processing the sounds in the brain.
A hearing disorder can lead to things including communication problems.
Purpose
Information on hearing function disorders is important in patient nursing and care and particularly in communication with the patient.
Evidence Base
The definitions of the concepts were (partially) taken from the ICNP definitions.
Information Model
Type | Id | Concept | Card. | Definition | DefinitionCode | Reference | ||||||||
NL-CM:4.17.1 | HearingFunction | Root concept of the HearingFunction information model. This concept contains all data elements of the HearingFunction information model. | ||||||||||||
NL-CM:4.17.3 | HearingFunction | 1 | The faculty of hearing due to responses to stimuli from auditory organs, capacity to hear. |
|
| |||||||||
NL-CM:4.17.4 | HearingAid::MedicalDevice | 0..* | The medical aid used to help the patient hear. |
|
| |||||||||
NL-CM:10.1.3 | ProductType | The type of product used to help the patient hear. |
| |||||||||||
NL-CM:10.1.6 | DeviceAnatomicalLocation | The anatomical location of the hearing aid, such as: ‘left ear’. |
|
| ||||||||||
NL-CM:4.17.2 | Comment | 0..1 | A comment on the hearing function. |
|
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
FunctieHoren | |
HoorFunctie | Verminderde gehoorfunctie |
HorenHulpmiddel | |
ProductType | Gehoorapparaat |
HulpmiddelAnatomischeLocatie | Linkeroor |
Toelichting | Door duidelijk articuleren en langzaam te praten kan patiënt redelijk verstaan. |
References
1. International Classification of Functioning Disability and Health (ICF) [Online] Beschikbaar op:http:/www.rivm.nl/who-fic/icf.htm [Geraadpleegd: 13 februari 2015]
Valuesets
DeviceAnatomicalLocationCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.4.17.3 | Binding: Extensible |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
Left ear structure | 89644007 | SNOMED CT | 2.16.840.1.113883.6.96 | Linkeroor |
Right ear structure | 25577004 | SNOMED CT | 2.16.840.1.113883.6.96 | Rechteroor |
Both ears | 34338003 | SNOMED CT | 2.16.840.1.113883.6.96 | Beide oren |
HearingAidTypeCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.4.17.2 | Binding: Extensible |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
Geen | 0 | Hulpmiddelen gehoor | 2.16.840.1.113883.2.4.3.11.22.211 | Geen |
Hearing aid | 6012004 | SNOMED CT | 2.16.840.1.113883.6.96 | Gehoorapparaat |
Aid to hearing [DEPRECATED] | 272182005 | SNOMED CT | 2.16.840.1.113883.6.96 | Gehoorapparaat |
HearingFunctionCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.4.17.1 | Binding: Required |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
Hearing normal | 162339002 | SNOMED CT | 2.16.840.1.113883.6.96 | Geen gehoorstoornis |
Hearing loss | 15188001 | SNOMED CT | 2.16.840.1.113883.6.96 | Verminderde gehoorfunctie |
Complete deafness | 8531006 | SNOMED CT | 2.16.840.1.113883.6.96 | Volledig doof |
This information model in other releases
- Release 2015, (Version 1.0)
- Release 2016, (Version 3.0)
- Release 2017, (Version 3.1)
- Prerelease 2018-2, (Version 3.1)
- Release 2020, (Version 3.2)
- Prerelease 2021-2, (Version 3.2.1)
- Prerelease 2022-1, (Version 3.3)
- Prerelease 2023-1, (Version 3.3)
- Prerelease 2024-1, (Version 3.3)
Information model references
This information model refers to
This information model is used in
- --
Technical specifications in HL7v3 CDA and HL7 FHIR
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
- HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
- HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
Downloads
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Prerelease 2019-2
SNOMED CT and LOINC codes are based on:
- SNOMED Clinical Terms version: 20190731 [R] (July 2019 Release)
- LOINC version 2.64
Conditions for use are located on the mainpage
This page is generated on 03/02/2020 01:26:38 with ZibExtraction v. 4.0.7338.2051