Stoma-v1.0(2015EN): verschil tussen versies
Geen bewerkingssamenvatting |
Geen bewerkingssamenvatting |
||
(2 tussenliggende versies door dezelfde gebruiker niet weergegeven) | |||
Regel 1: | Regel 1: | ||
==General information== | <!-- Hieronder wordt een transclude page aangeroepen --> | ||
Name: '''nl.nfu.Stoma''' [[Bestand:NL.png|link=Stoma-v1.0(2015NL)]]<BR> | {{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.5.2(EN)|1|Stoma-v1.0(2015EN)}} | ||
Version: '''1.0''' <br> | <!-- Tot hier de transclude page --> | ||
HCIM Status:Final<br> | ==General information<!--hdGeneralInformation-->== | ||
Release: '''2015''' <br> | Name<!--hdName-->: '''nl.nfu.Stoma''' [[Bestand:NL.png|link=Stoma-v1.0(2015NL)]]<BR> | ||
Release status: Published<br> | Version<!--hdVersion-->: '''1.0''' <br> | ||
Release date: 8-9-2015 | HCIM Status<!--hdStatus-->:Final<br> | ||
Release<!--hdPublication-->: '''2015''' <br> | |||
Release status<!--hdPublicationStatus-->: Published<br> | |||
Release date<!--hdPublicationDate-->: 8-9-2015 | |||
----- | ----- | ||
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2015(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2015(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> | ||
==Metadata== | ==Metadata== | ||
Regel 61: | Regel 64: | ||
==Revision History== | ==Revision History== | ||
<div class="mw-collapsible mw-collapsed"> | <div class="mw-collapsible mw-collapsed"> | ||
''Only available in Dutch'' | ''Only available in Dutch<!--noTranslation-->'' | ||
<u>Publicatieversie 1.0</u> (01-07-2015). | <u>Publicatieversie 1.0</u> (01-07-2015). | ||
Regel 74: | Regel 77: | ||
==Information Model== | ==Information Model== | ||
<BR> | <BR> | ||
<imagemap> Bestand:Stoma-v1.0Model( | <imagemap> Bestand:Stoma-v1.0Model(2015EN).png | center | ||
rect | rect 281 78 407 148 [[NursingIntervention-v1.0(2015EN)]] | ||
rect | rect 35 447 231 497 [[#StomaAnatomicalLocationCodelist]] | ||
rect | rect 475 201 601 271 [[#10782]] | ||
rect | rect 281 325 407 395 [[#10784]] | ||
rect | rect 281 447 407 497 [[#StomaTypeCodelist]] | ||
rect | rect 475 325 601 395 [[MedicalDevice-v1.2(2015EN)]] | ||
rect | rect 96 325 222 395 [[#10780]] | ||
rect | rect 97 201 223 271 [[#10772]] | ||
rect | rect 292 196 396 276 [[#10778]] | ||
desc none | desc none | ||
</imagemap> | </imagemap> | ||
Regel 89: | Regel 92: | ||
{| border= "1" width="1500px" style = "font-size: 9.5pt; border: solid 1px silver; border-collapse:collapse;" cellpadding = "3px" cellspacing ="0px" | {| border= "1" width="1500px" style = "font-size: 9.5pt; border: solid 1px silver; border-collapse:collapse;" cellpadding = "3px" cellspacing ="0px" | ||
|-style="background-color: #1F497D; color: white; font-weight: bold; font-variant: small-caps; " | |-style="background-color: #1F497D; color: white; font-weight: bold; font-variant: small-caps; " | ||
|style="width:30px;"|Type||style="width:100px;"|Id||colspan="6 " style="width:140px;"|Concept||Card.||style="width: 600px;"|Definition||style="width:200px;"|DefinitionCode||style="width:200px;"|Reference | |style="width:30px;"|Type<!--imType-->||style="width:100px;"|Id<!--imId-->||colspan="6 " style="width:140px;"|Concept<!--imConcept-->||Card.<!--imCard-->||style="width: 600px;"|Definition<!--imDefinition-->||style="width:200px;"|DefinitionCode<!--imDefinitionCode-->||style="width:200px;"|Reference<!--imReference--> | ||
|-style="vertical-align:top; background-color: #E3E3E3; " | |-style="vertical-align:top; background-color: #E3E3E3; " | ||
|style = "text-align:center" |[[Bestand: block.png| 20px | link=]] | |style = "text-align:center" |[[Bestand: block.png| 20px | link=]] | ||
Regel 99: | Regel 102: | ||
{| | {| | ||
|- | |- | ||
|<span | |<span title = "Codesystem: SNOMED CT>[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=416789009 416789009] Stoma</span> | ||
|} | |} | ||
| | | | ||
Regel 175: | Regel 178: | ||
{| | {| | ||
|- | |- | ||
|<span | |<span title = "Codesystem: LOINC>[https://terminologie.nictiz.nl/art-decor/loinc?conceptId=48767-8 48767-8] Annotation comment</span> | ||
|} | |} | ||
| | | | ||
|} | |} | ||
Columns Concept and DefinitionCode: hover over the values for more information<BR> | Columns Concept and DefinitionCode: hover over the values for more information<!--imHover--><BR> | ||
For explanation of the symbols, please see the legend page [[Bestand:list2.png|link=Legend]] | For explanation of the symbols, please see the legend page<!--imLegend--> [[Bestand:list2.png|link=Legend<!--wikiLegend-->]] | ||
==Example Instances== | ==Example Instances== | ||
''Only available in Dutch'' | ''Only available in Dutch<!--noTranslation-->'' | ||
{|class="wikitable" width="610px" style= "font-size: 9.5pt;" | {|class="wikitable" width="610px" style= "font-size: 9.5pt;" | ||
Regel 216: | Regel 219: | ||
{| class="wikitable" width="60%" | {| class="wikitable" width="60%" | ||
|-style='vertical-align:top; background-color: #E8D7BE;' | |-style='vertical-align:top; background-color: #E8D7BE;' | ||
|Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.5.2.2 | |Valueset OID<!--vsValuesetOID-->: 2.16.840.1.113883.2.4.3.11.60.40.2.5.2.2 | ||
|Binding<!--vsBindingTag-->: | |||
|} | |} | ||
{| class="wikitable" width="60% " | {| class="wikitable" width="60% " | ||
|-style="background-color: #1F497D; color: white; font-weight: bold; " | |-style="background-color: #1F497D; color: white; font-weight: bold; " | ||
|Conceptname | |Conceptname<!--vsConceptName--> | ||
|Codesystem name||Codesystem OID | |Codesystem name<!--vsConceptSystemName-->||Codesystem OID<!--vsConceptSystemOID--> | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|SNOMED CT: <<91723000 <noWiki>|</noWiki> anatomical structure <noWiki>|</noWiki> | |SNOMED CT: <<[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=91723000 91723000]<noWiki>|</noWiki>anatomical structure<noWiki>|</noWiki> | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
|} | |} | ||
=== StomaTypeCodelist=== | === StomaTypeCodelist=== | ||
{| class="wikitable" width="60%" | {| class="wikitable" width="60%" | ||
|-style='vertical-align:top; background-color: #E8D7BE;' | |-style='vertical-align:top; background-color: #E8D7BE;' | ||
|Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.5.2.1 | |Valueset OID<!--vsValuesetOID-->: 2.16.840.1.113883.2.4.3.11.60.40.2.5.2.1 | ||
|Binding<!--vsBindingTag-->: | |||
|} | |} | ||
{| class="wikitable" width="60% " | {| class="wikitable" width="60% " | ||
|-style="background-color: #1F497D; color: white; font-weight: bold; " | |-style="background-color: #1F497D; color: white; font-weight: bold; " | ||
|Conceptname | |Conceptname<!--vsConceptName--> | ||
|Conceptcode | |Conceptcode<!--vsConceptCode--> | ||
|Codesystem name||Codesystem OID | |Codesystem name<!--vsConceptSystemName-->||Codesystem OID<!--vsConceptSystemOID--> | ||
|Description | |Description<!--vsDescription--> | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|urological stoma | |urological stoma | ||
|281601009 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=281601009 281601009] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 247: | Regel 251: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|double-barrelled colostomy | |double-barrelled colostomy | ||
|261072008 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=261072008 261072008] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 253: | Regel 257: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|end colostomy - stoma | |end colostomy - stoma | ||
|261030007 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=261030007 261030007] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 259: | Regel 263: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|loop ileostomy stoma | |loop ileostomy stoma | ||
|311413000 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=311413000 311413000] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 265: | Regel 269: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|end ileostomy stoma | |end ileostomy stoma | ||
|311412005 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=311412005 311412005] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 271: | Regel 275: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|tracheostomy stoma | |tracheostomy stoma | ||
|280361007 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=280361007 280361007] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 283: | Regel 287: | ||
|} | |} | ||
==This information model in other releases<!--ftOtherReleases-->== | |||
==This information model in other releases== | <!-- Hieronder wordt een transclude page aangeroepen --> | ||
< | {{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.5.2(EN)|2|2015}} | ||
< | <!-- Tot hier de transclude page --> | ||
==Information model references<!--ftReferences-->== | |||
< | ====This information model refers to<!--ftRefersTo-->==== | ||
*[[MedicalDevice-v1.2(2015EN)|MedicalDevice-v1.2]] | |||
*[[NursingIntervention-v1.0(2015EN)|NursingIntervention-v1.0]] | |||
====This information model is used in<!--ftReferredBy-->==== | |||
*[[BladderFunction-v1.0(2015EN)|BladderFunction-v1.0]] | |||
*[[BowelFunction-v1.0(2015EN)|BowelFunction-v1.0]] | |||
==Technical specifications in HL7v3 CDA and HL7 FHIR<!--ftHeader-->== | |||
To exchange information based on health and care information models, additional, more technical specifications are required.<BR> | To exchange information based on health and care information models, additional, more technical specifications are required.<BR> | ||
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications: | Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro--> | ||
<ul> | <ul> | ||
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2015bbr-?id=2.16.840.1.113883.2.4.3.11.60.5.4.2.5.2&effectiveDate=2015-09-08T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li> | <li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2015bbr-?id=2.16.840.1.113883.2.4.3.11.60.5.4.2.5.2&effectiveDate=2015-09-08T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li> | ||
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR | <li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2015}}</li> | ||
</ul> | </ul> | ||
This information model is also available as [[Media:nl.nfu.Stoma-v1.0(2015EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.nfu.Stoma-v1.0(2015EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]] | ==Downloads<!--ftDownloadTitle-->== | ||
==About this information== | This information model is also available as [[Media:nl.nfu.Stoma-v1.0(2015EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.nfu.Stoma-v1.0(2015EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]<!--ftDownloads--> | ||
The information in this wikipage is based on ''Registratie aan de bron'' publication 2015 including errata dd. 16-07-2015 <BR> | ==About this information<!--ftHeader2-->== | ||
Conditions for use are located on the mainpage [[Bestand:list2.png|link=HCIM_Mainpage]]<BR> | The information in this wikipage is based on<!--ftInfoBase--> ''Registratie aan de bron'' publication 2015 including errata dd. 16-07-2015 <BR> | ||
This page is generated on 24/ | Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR> | ||
This page is generated on 24/12/2018 12:36:47 with ZibExtraction v. 3.0.6932.1989<!--ftDate--> <BR> | |||
----- | ----- | ||
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2015(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2015(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> |
Huidige versie van 24 dec 2018 om 12:15
General information
Name: nl.nfu.Stoma
Version: 1.0
HCIM Status:Final
Release: 2015
Release status: Published
Release date: 8-9-2015
Metadata
DCM::CoderList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::ContactInformation.Address | * |
DCM::ContactInformation.Name | * |
DCM::ContactInformation.Telecom | * |
DCM::ContentAuthorList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::CreationDate | 16-10-2014 |
DCM::DeprecatedDate | |
DCM::DescriptionLanguage | nl |
DCM::EndorsingAuthority.Address | |
DCM::EndorsingAuthority.Name | NFU & V&VN |
DCM::EndorsingAuthority.Telecom | |
DCM::Id | 2.16.840.1.113883.2.4.3.11.60.40.3.5.2 |
DCM::KeywordList | Stoma, urostoma |
DCM::LifecycleStatus | Final |
DCM::ModelerList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::Name | nl.nfu.Stoma |
DCM::PublicationDate | 8-9-2015 |
DCM::PublicationStatus | Published |
DCM::ReviewerList | Projectgroep RadB Verpleegkundige Gegevens & Kerngroep Registratie aan de Bron |
DCM::RevisionDate | 8-9-2015 |
DCM::Superseeds | |
DCM::Version | 1.0 |
HCIM::PublicationLanguage | EN |
Revision History
Only available in Dutch
Publicatieversie 1.0 (01-07-2015).
Concept
A stoma is an unnatural, surgically created opening connecting a body cavity with the outside world. A stoma is created e.g. as an exit opening for feces or urine in the event that they cannot leave the body naturally. In the case of a tracheostomy, the stoma is intended to facilitate breathing if that is no longer possible via the oral, nasal and throat cavity.
Purpose
Information on present stomas is recorded to inform other healthcare providers. This information is of importance in determining the care required for the patient. In a transfer situation, the information offers the option to realize continuity of care by organizing specific expertise and materials in advance, for example.
Information Model
Type | Id | Concept | Card. | Definition | DefinitionCode | Reference | |||||||
NL-CM:5.2.1 | Stoma | Root concept of the Stoma building block. This root concept contains all data elements of the Stoma building block. |
|
||||||||||
NL-CM:5.2.2 | StomaType | 1 | Stoma type indicates which body cavity the stoma is in and the kind of stoma used. |
| |||||||||
NL-CM:5.2.3 | StomaMaterial::MedicalAid | 0..* | Stoma material describes the medical aids used, such as a skin plate (the adhesive part around the stoma), the stoma pouch (to catch the stoma output) and other stoma aids for caring for the stoma. For tracheostomies, it also describes aids such as voice prostheses and stoma filters.
Catheters inserted through the stoma such as tracheal cannulas are not described in this concept. These aids must be modeled in a higher building block describing the catheter and referring to the stoma. |
| |||||||||
NL-CM:5.2.4 | AnatomicalLocation | 0..1 | Anatomical location of the stoma on the patient. |
| |||||||||
NL-CM:5.2.5 | CreationDate | 0..1 | The date on which the stoma was created in the patient. A vague date, such as only the year, is permitted. | ||||||||||
NL-CM:5.2.6 | NursingProcedure | 0..* | The nursing procedure needed to care for the stoma. |
| |||||||||
NL-CM:5.2.7 | Explanation | 0..1 | An explanation of the stoma. |
|
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
Stoma | |
StomaType | Eindstandige colostoma |
AanlegDatum | 2014 |
AnatomischeLocatie | Buik, rechtsonder |
StomaMateriaal | |
ProductType | Stomazakje |
Toelichting | - |
References
1. V&VN afdeling Stomaverpleegkundigen. Evidence-based Richtlijn Stomazorg Nederland. (2012) [Online] Beschikbaar op:http://www.mdl.nl/uploads/240/1143/Evidence-based_Richtlijn_Stomazorg_Nederland.pdf [Geraadpleegd: 13 februari 2015]
Valuesets
StomaAnatomicalLocationCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.5.2.2 | Binding: |
Conceptname | Codesystem name | Codesystem OID |
SNOMED CT: <<91723000|anatomical structure| | SNOMED CT | 2.16.840.1.113883.6.96 |
StomaTypeCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.5.2.1 | Binding: |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
urological stoma | 281601009 | SNOMED CT | 2.16.840.1.113883.6.96 | urostoma |
double-barrelled colostomy | 261072008 | SNOMED CT | 2.16.840.1.113883.6.96 | dubbelloops colostoma |
end colostomy - stoma | 261030007 | SNOMED CT | 2.16.840.1.113883.6.96 | eindstandige colostoma |
loop ileostomy stoma | 311413000 | SNOMED CT | 2.16.840.1.113883.6.96 | dubbelloops ileostoma |
end ileostomy stoma | 311412005 | SNOMED CT | 2.16.840.1.113883.6.96 | eindstandige ileostoma |
tracheostomy stoma | 280361007 | SNOMED CT | 2.16.840.1.113883.6.96 | tracheostoma |
other | OTH | NullFlavor | 2.16.840.1.113883.5.1008 | anders |
This information model in other releases
- Release 2016, (Version 3.0)
- Release 2017, (Version 3.2)
- Prerelease 2018-2, (Version 3.2)
- Prerelease 2019-2, (Version 3.2)
- Release 2020, (Version 3.3)
- Prerelease 2021-2, (Version 3.3)
- Prerelease 2022-1, (Version 3.4)
- Prerelease 2023-1, (Version 3.4)
- Prerelease 2024-1, (Version 3.4)
Information model references
This information model refers to
This information model is used in
Technical specifications in HL7v3 CDA and HL7 FHIR
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
- HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
- HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
Downloads
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Registratie aan de bron publication 2015 including errata dd. 16-07-2015
Conditions for use are located on the mainpage
This page is generated on 24/12/2018 12:36:47 with ZibExtraction v. 3.0.6932.1989