==General information== | <!-- Hieronder wordt een transclude page aangeroepen --> | ||
Name: '''nl.nfu.Infusion''' [[Bestand:NL.png|link=Infuus-v1.0(2015NL)]]<BR> | {{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.10.2(EN)|1|Infusion-v1.0(2015EN)}} | ||
Version: '''1.0''' <br> | <!-- Tot hier de transclude page --> | ||
HCIM Status:Final<br> | ==General information<!--hdGeneralInformation-->== | ||
Release: '''2015''' <br> | Name<!--hdName-->: '''nl.nfu.Infusion''' [[Bestand:NL.png|link=Infuus-v1.0(2015NL)]]<BR> | ||
Release status: Published<br> | Version<!--hdVersion-->: '''1.0''' <br> | ||
Release date: 8-9-2015 | HCIM Status<!--hdStatus-->:Final<br> | ||
Release<!--hdPublication-->: '''2015''' <br> | |||
Release status<!--hdPublicationStatus-->: Published<br> | |||
Release date<!--hdPublicationDate-->: 8-9-2015 | |||
----- | ----- | ||
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2015(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2015(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> | ||
==Metadata== | ==Metadata== | ||
Regel 61: | Regel 64: | ||
==Revision History== | ==Revision History== | ||
<div class="mw-collapsible mw-collapsed"> | <div class="mw-collapsible mw-collapsed"> | ||
''Only available in Dutch'' | ''Only available in Dutch<!--noTranslation-->'' | ||
<u>Publicatieversie 1.0</u> (01-07-2015). | <u>Publicatieversie 1.0</u> (01-07-2015). | ||
Regel 83: | Regel 86: | ||
==Information Model== | ==Information Model== | ||
<BR> | <BR> | ||
<imagemap> Bestand:Infusion-v1.0Model( | <imagemap> Bestand:Infusion-v1.0Model(2015EN).png | center | ||
rect | rect 189 70 322 140 [[PlannedCareActivityForTransfer-v1.2.1(2015EN)]] | ||
rect | rect 707 186 863 236 [[#InfusionCatheterTypeCodelist]] | ||
rect | rect 739 67 829 137 [[#9569]] | ||
rect | rect 294 576 434 646 [[MedicationAdministration-v1.0(2015EN)]] | ||
rect | rect 562 66 702 136 [[MedicalDevice-v1.2(2015EN)]] | ||
rect | rect 427 190 527 270 [[#9570]] | ||
rect | rect 525 576 665 646 [[MedicalDevice-v1.2(2015EN)]] | ||
rect | rect 189 192 322 262 [[NursingIntervention-v1.0(2015EN)]] | ||
rect | rect 424 71 530 141 [[#10817]] | ||
rect | rect 426 453 535 523 [[#10861]] | ||
rect | rect 612 387 718 457 [[#10862]] | ||
rect | rect 611 292 717 362 [[#10864]] | ||
rect | rect 772 303 909 351 [[#LumenLocationCodelist]] | ||
rect | rect 772 397 909 447 [[#LineStatusCodelist]] | ||
rect | rect 189 452 365 522 [[#10867]] | ||
rect | rect 429 327 529 397 [[#10872]] | ||
rect | rect 189 329 322 399 [[MedicationAdministration-v1.0(2015EN)]] | ||
desc none | desc none | ||
</imagemap> | </imagemap> | ||
Regel 106: | Regel 109: | ||
{| border= "1" width="1500px" style = "font-size: 9.5pt; border: solid 1px silver; border-collapse:collapse;" cellpadding = "3px" cellspacing ="0px" | {| border= "1" width="1500px" style = "font-size: 9.5pt; border: solid 1px silver; border-collapse:collapse;" cellpadding = "3px" cellspacing ="0px" | ||
|-style="background-color: #1F497D; color: white; font-weight: bold; font-variant: small-caps; " | |-style="background-color: #1F497D; color: white; font-weight: bold; font-variant: small-caps; " | ||
|style="width:30px;"|Type||style="width:100px;"|Id||colspan="6 " style="width:140px;"|Concept||Card.||style="width: 600px;"|Definition||style="width:200px;"|DefinitionCode||style="width:200px;"|Reference | |style="width:30px;"|Type<!--imType-->||style="width:100px;"|Id<!--imId-->||colspan="6 " style="width:140px;"|Concept<!--imConcept-->||Card.<!--imCard-->||style="width: 600px;"|Definition<!--imDefinition-->||style="width:200px;"|DefinitionCode<!--imDefinitionCode-->||style="width:200px;"|Reference<!--imReference--> | ||
|-style="vertical-align:top; background-color: #E3E3E3; " | |-style="vertical-align:top; background-color: #E3E3E3; " | ||
|style = "text-align:center" |[[Bestand: block.png| 20px | link=]] | |style = "text-align:center" |[[Bestand: block.png| 20px | link=]] | ||
Regel 179: | Regel 182: | ||
{| | {| | ||
|- | |- | ||
|<span | |<span title = "Codesystem: LOINC>[https://terminologie.nictiz.nl/art-decor/loinc?conceptId=48767-8 48767-8] Annotation comment</span> | ||
|} | |} | ||
| | | | ||
Regel 259: | Regel 262: | ||
{| | {| | ||
|- | |- | ||
|<span | |<span title = "Codesystem: SNOMED CT>[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=440132002 440132002] Parenteral dosage form product</span> | ||
|} | |} | ||
| | | | ||
Regel 293: | Regel 296: | ||
{| | {| | ||
|- | |- | ||
|<span | |<span title = "Codesystem: LOINC>[https://terminologie.nictiz.nl/art-decor/loinc?conceptId=48767-8 48767-8] Annotation comment</span> | ||
|} | |} | ||
| | | | ||
|} | |} | ||
Columns Concept and DefinitionCode: hover over the values for more information<BR> | Columns Concept and DefinitionCode: hover over the values for more information<!--imHover--><BR> | ||
For explanation of the symbols, please see the legend page [[Bestand:list2.png|link=Legend]] | For explanation of the symbols, please see the legend page<!--imLegend--> [[Bestand:list2.png|link=Legend<!--wikiLegend-->]] | ||
==Example Instances== | ==Example Instances== | ||
''Only available in Dutch'' | ''Only available in Dutch<!--noTranslation-->'' | ||
{|class="wikitable" width="723px" style= "font-size: 9.5pt;" | {|class="wikitable" width="723px" style= "font-size: 9.5pt;" | ||
Regel 511: | Regel 514: | ||
{| class="wikitable" width="60%" | {| class="wikitable" width="60%" | ||
|-style='vertical-align:top; background-color: #E8D7BE;' | |-style='vertical-align:top; background-color: #E8D7BE;' | ||
|Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.10.2.1 | |Valueset OID<!--vsValuesetOID-->: 2.16.840.1.113883.2.4.3.11.60.40.2.10.2.1 | ||
|Binding<!--vsBindingTag-->: | |||
|} | |} | ||
{| class="wikitable" width="60% " | {| class="wikitable" width="60% " | ||
|-style="background-color: #1F497D; color: white; font-weight: bold; " | |-style="background-color: #1F497D; color: white; font-weight: bold; " | ||
|Conceptname | |Conceptname<!--vsConceptName--> | ||
|Conceptcode | |Conceptcode<!--vsConceptCode--> | ||
|Codesystem name||Codesystem OID | |Codesystem name<!--vsConceptSystemName-->||Codesystem OID<!--vsConceptSystemOID--> | ||
|Description | |Description<!--vsDescription--> | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Peripheral intravenous catheter | |Peripheral intravenous catheter | ||
|82449006 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=82449006 82449006] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 527: | Regel 531: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Central venous catheter | |Central venous catheter | ||
|52124006 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=52124006 52124006] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 533: | Regel 537: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Epidural catheter | |Epidural catheter | ||
|30610008 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=30610008 30610008] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 539: | Regel 543: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Arterial catheter | |Arterial catheter | ||
|303727009 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=303727009 303727009] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 545: | Regel 549: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Implantable venous catheter | |Implantable venous catheter | ||
|102318003 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=102318003 102318003] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 551: | Regel 555: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Haemodialysis catheter | |Haemodialysis catheter | ||
|450866001 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=450866001 450866001] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 562: | Regel 566: | ||
|Anders | |Anders | ||
|} | |} | ||
=== LineStatusCodelist=== | === LineStatusCodelist=== | ||
{| class="wikitable" width="60%" | {| class="wikitable" width="60%" | ||
|-style='vertical-align:top; background-color: #E8D7BE;' | |-style='vertical-align:top; background-color: #E8D7BE;' | ||
|Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.10.2.3 | |Valueset OID<!--vsValuesetOID-->: 2.16.840.1.113883.2.4.3.11.60.40.2.10.2.3 | ||
|Binding<!--vsBindingTag-->: | |||
|} | |} | ||
{| class="wikitable" width="60% " | {| class="wikitable" width="60% " | ||
|-style="background-color: #1F497D; color: white; font-weight: bold; " | |-style="background-color: #1F497D; color: white; font-weight: bold; " | ||
|Conceptname | |Conceptname<!--vsConceptName--> | ||
|Conceptcode | |Conceptcode<!--vsConceptCode--> | ||
|Codesystem name||Codesystem OID | |Codesystem name<!--vsConceptSystemName-->||Codesystem OID<!--vsConceptSystemOID--> | ||
|Description | |Description<!--vsDescription--> | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Lopend | |Lopend | ||
Regel 605: | Regel 609: | ||
|Anders | |Anders | ||
|} | |} | ||
=== LumenLocationCodelist=== | === LumenLocationCodelist=== | ||
{| class="wikitable" width="60%" | {| class="wikitable" width="60%" | ||
|-style='vertical-align:top; background-color: #E8D7BE;' | |-style='vertical-align:top; background-color: #E8D7BE;' | ||
|Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.10.2.2 | |Valueset OID<!--vsValuesetOID-->: 2.16.840.1.113883.2.4.3.11.60.40.2.10.2.2 | ||
|Binding<!--vsBindingTag-->: | |||
|} | |} | ||
{| class="wikitable" width="60% " | {| class="wikitable" width="60% " | ||
|-style="background-color: #1F497D; color: white; font-weight: bold; " | |-style="background-color: #1F497D; color: white; font-weight: bold; " | ||
|Conceptname | |Conceptname<!--vsConceptName--> | ||
|Conceptcode | |Conceptcode<!--vsConceptCode--> | ||
|Codesystem name||Codesystem OID | |Codesystem name<!--vsConceptSystemName-->||Codesystem OID<!--vsConceptSystemOID--> | ||
|Description | |Description<!--vsDescription--> | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Proximal | |Proximal | ||
|40415009 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=40415009 40415009] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 625: | Regel 629: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Medial | |Medial | ||
|255561001 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=255561001 255561001] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 631: | Regel 635: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Distal | |Distal | ||
|46053002 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=46053002 46053002] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 637: | Regel 641: | ||
|} | |} | ||
==This information model in other releases<!--ftOtherReleases-->== | |||
==This information model in other releases== | <!-- Hieronder wordt een transclude page aangeroepen --> | ||
< | {{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.10.2(EN)|2|2015}} | ||
< | <!-- Tot hier de transclude page --> | ||
==Information model references<!--ftReferences-->== | |||
====This information model refers to<!--ftRefersTo-->==== | |||
== | *[[MedicalDevice-v1.2(2015EN)|MedicalDevice-v1.2]] | ||
*[[MedicationAdministration-v1.0(2015EN)|MedicationAdministration-v1.0]] | |||
*[[NursingIntervention-v1.0(2015EN)|NursingIntervention-v1.0]] | |||
*[[PlannedCareActivityForTransfer-v1.2.1(2015EN)|PlannedCareActivityForTransfer-v1.2.1]] | |||
====This information model is used in<!--ftReferredBy-->==== | |||
:-- | |||
==Technical specifications in HL7v3 CDA and HL7 FHIR<!--ftHeader-->== | |||
To exchange information based on health and care information models, additional, more technical specifications are required.<BR> | To exchange information based on health and care information models, additional, more technical specifications are required.<BR> | ||
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications: | Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro--> | ||
<ul> | <ul> | ||
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2015bbr-?id=2.16.840.1.113883.2.4.3.11.60.5.4.2.10.2&effectiveDate=2015-09-08T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li> | <li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2015bbr-?id=2.16.840.1.113883.2.4.3.11.60.5.4.2.10.2&effectiveDate=2015-09-08T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li> | ||
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR | <li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2015}}</li> | ||
</ul> | </ul> | ||
This information model is also available as [[Media:nl.nfu.Infusion-v1.0(2015EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.nfu.Infusion-v1.0(2015EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]] | ==Downloads<!--ftDownloadTitle-->== | ||
==About this information== | This information model is also available as [[Media:nl.nfu.Infusion-v1.0(2015EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.nfu.Infusion-v1.0(2015EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]<!--ftDownloads--> | ||
The information in this wikipage is based on ''Registratie aan de bron'' publication 2015 including errata dd. 16-07-2015 <BR> | ==About this information<!--ftHeader2-->== | ||
Conditions for use are located on the mainpage [[Bestand:list2.png|link=HCIM_Mainpage]]<BR> | The information in this wikipage is based on<!--ftInfoBase--> ''Registratie aan de bron'' publication 2015 including errata dd. 16-07-2015 <BR> | ||
This page is generated on 24/ | Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR> | ||
This page is generated on 24/12/2018 12:35:52 with ZibExtraction v. 3.0.6932.1989<!--ftDate--> <BR> | |||
----- | ----- | ||
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2015(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2015(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> |
Huidige versie van 24 dec 2018 om 12:14
General information
Name: nl.nfu.Infusion
Version: 1.0
HCIM Status:Final
Release: 2015
Release status: Published
Release date: 8-9-2015
Metadata
DCM::CoderList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::ContactInformation.Address | * |
DCM::ContactInformation.Name | * |
DCM::ContactInformation.Telecom | * |
DCM::ContentAuthorList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::CreationDate | 3-4-2014 |
DCM::DeprecatedDate | |
DCM::DescriptionLanguage | nl |
DCM::EndorsingAuthority.Address | |
DCM::EndorsingAuthority.Name | NFU & V&VN |
DCM::EndorsingAuthority.Telecom | |
DCM::Id | 2.16.840.1.113883.2.4.3.11.60.40.3.10.2 |
DCM::KeywordList | Infuus, Katheter,Toedieningssyteem |
DCM::LifecycleStatus | Final |
DCM::ModelerList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::Name | nl.nfu.Infuus |
DCM::PublicationDate | 8-9-2015 |
DCM::PublicationStatus | Published |
DCM::ReviewerList | Projectgroep RadB Verpleegkundige Gegevens & Kerngroep Registratie aan de Bron |
DCM::RevisionDate | 8-9-2015 |
DCM::Superseeds | |
DCM::Version | 1.0 |
HCIM::PublicationLanguage | EN |
Revision History
Only available in Dutch
Publicatieversie 1.0 (01-07-2015).
Concept
A drip is a machine that slowly injects fluid into a blood vessel. The drip has a number of components.
The drip contains:
- the (peripheral) cannula or the (central) catheter put into the patient peripherally or centrally;
- the administering system connected to the cannula/catheter allowing the administered fluid to run;
- the drip bag containing the fluid.
Multiple administering systems may be connected to one cannula/catheter. Furthermore, a central venous catheter may have multiple lumens.
Arterial and epidural catheters also exist in addition to venous catheters.
Purpose
The purpose of a drip is usually to administer fluid and/or medication.
Information on present drips is recorded to inform other healthcare providers. This information is of importance in determining the care required for the patient and in safely administering medication. In a transfer situation, the information offers the option to realize continuity of care by organizing specific expertise and materials in advance, for example.
Information Model
Type | Id | Concept | Card. | Definition | DefinitionCode | Reference | ||||||||
NL-CM:10.2.1 | Drip | Root concept of the Drip building block. This root concept contains all data elements of the Drip building block. | ||||||||||||
NL-CM:10.2.3 | InfusionCatheter::MedicalAid | 0..1 | DripCatheter describes the presence of a drip catheter. If this is the case, the date of placement and insertion opening can be described in addition to the type of catheter. Furthermore, it offers the option to record identification information of the cannula/catheter if desired. |
| ||||||||||
NL-CM:10.1.3 | ProductType | A description of the type of cannula/catheter. |
| |||||||||||
NL-CM:10.2.4 | NursingProcedure | 0..* | A nursing procedure/point of attention in providing the drip and administering any fluid. |
| ||||||||||
NL-CM:10.2.5 | PlannedProcedure::PlannedCareActivity | 0..* | A planned (nursing) procedure or 'clinical reminder' in providing the drip, in which information can be included such as the date on which the drip (cannula and/or drip system) must be replaced. |
| ||||||||||
NL-CM:10.2.8 | Explanation | 0..1 | An explanation of the drip. |
|
||||||||||
NL-CM:10.2.10 | LumenOrLine | 1..3 | Container of the LumenOrLine concept. This container contains all data elements of the LumenOrLine concept.
Central lines can contain one or more lumens; peripheral drips do not have lumens and only have one line. |
|||||||||||
NL-CM:10.2.9 | LineStatus | 0..1 | LineStatus is used to indicate whether it is a running drip, whether it has been capped, or has been fitted with a heparin lock, etc. |
| ||||||||||
NL-CM:10.2.11 | LumenLocation | 0..1 | For central venous catheters with multiple lumens, LumenLocation indicates the relative position of the lumen with respect to the insertion opening. |
| ||||||||||
NL-CM:10.2.13 | LockFluid::MedicationAdministration | 0..1 | The description of the fluid used as an anticoagulation lock, such as heparin. |
| ||||||||||
NL-CM:10.2.7 | AdministeringSystem | 0..* | Container of the AdministeringSystem concept. This container contains all data elements of the AdministeringSystem concept.
The administering system contains the entire system making the fluid run from the drip bag via the cannula/catheter to the patient. This also includes any three-way valves/connecting joints used. |
|||||||||||
NL-CM:10.2.2 | DripFluid::MedicationAdministration | 1 | The description of the fluid administered through the drip and the dose administered, as given in the medication prescription. |
|
| |||||||||
NL-CM:10.2.6 | Peripheral::MedicalAid | 0..* | A description of medical aids required for administering the drip fluid and placing the catheter, such as a volumetric drip pump, syringe and drip bag. |
| ||||||||||
NL-CM:10.2.12 | AdministeringSystemExplanation | 0..1 | An explanation of the administering system. |
|
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
Infuus | |||
Infuuskatheter | |||
ProductType | Centraal veneuze katheter | ||
BeginDatum | 30-11-2014 | ||
HulpmiddelAnatomischeLocatie | Vena subclavia links | ||
VerpleegkundigeActie | |||
Activiteit | Insteekopening controleren. | ||
GeplandeActie | |||
Activiteit | Op 31-12-2014 katheter verschonen. | ||
LumenOfLijn | |||
LumenLocatie | Proximaal | ||
LijnStatus | Lopend | ||
ToedieningsSysteem | |||
ToedieningssysteemToelichting | - | ||
Randapparaat | |||
ProductType | Infuuspomp | ||
InfuusVloeistof | |||
ProductNaam | TPV | ||
Inloopsnelheid | 1 liter per 24 uur | ||
LumenOfLijn | |||
Lumen locatie | Mediaal | ||
LijnStatus | Zoutspoelingsslot | ||
SlotVloeistof | |||
ProductNaam | NaCl 0.9 % | ||
Keerdosis | 5ml | ||
LumenOfLijn | |||
LumenLocatie | Distaal | ||
LijnStatus | Lopend | ||
ToedieningsSysteem | |||
ToedieningssysteemToelichting | - | ||
Randapparaat | |||
ProductType | Infuuspomp | ||
InfuusVloeistof | |||
ProductNaam | NaCl 0.9 % | ||
Inloopsnelheid | 500 ml per 24 uur | ||
Toelichting | - |
Infuus | |||
Infuuskatheter | |||
ProductType | Perifeer intraveneus infuus | ||
BeginDatum | 28-11-2014 | ||
HulpmiddelAnatomischeLocatie | Linker onderarm | ||
VerpleegkundigeActie | |||
Activiteit | Insteekopening controleren. | ||
GeplandeActie | |||
Activiteit | Op 2-12 systeem verschonen. | ||
LumenOfLijn | |||
LumenLocatie | - | ||
LijnStatus | Lopend | ||
ToedieningsSysteem | |||
ToedieningssysteemToelichting | - | ||
Randapparaat | |||
ProductType | Spuitenpomp (perfusor) | ||
InfuusVloeistof | |||
ProductNaam | NaCl 0,9% + medicatie 5000 E heparine (totaal 48ml) | ||
Inloopsnelheid | 2ml per uur | ||
ToedieningsSysteem | |||
ToedieningssysteemToelichting | - | ||
Randapparaat | |||
ProductType | Infuuspomp | ||
InfuusVloeistof | |||
ProductNaam | NaCl/gluc | ||
Inloopsnelheid | 500 ml / 24 uur | ||
Toelichting | - |
References
1. Verpleegkundige Intensive Care Protocollen [Online] Beschikbaar op:http://ic.venvn.nl/Downloads/Verpleegkundige-Intensive-Care-Protocollen [Geraadpleegd: 13 februari 2015]
Valuesets
InfusionCatheterTypeCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.10.2.1 | Binding: |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
Peripheral intravenous catheter | 82449006 | SNOMED CT | 2.16.840.1.113883.6.96 | Perifeer intraveneus infuus |
Central venous catheter | 52124006 | SNOMED CT | 2.16.840.1.113883.6.96 | Centraal veneuze katheter |
Epidural catheter | 30610008 | SNOMED CT | 2.16.840.1.113883.6.96 | Epidurale katheter |
Arterial catheter | 303727009 | SNOMED CT | 2.16.840.1.113883.6.96 | Arteriële katheter |
Implantable venous catheter | 102318003 | SNOMED CT | 2.16.840.1.113883.6.96 | Port-a-cath |
Haemodialysis catheter | 450866001 | SNOMED CT | 2.16.840.1.113883.6.96 | Hemodialyse katheter |
Other | OTH | NullFlavor | 2.16.840.1.113883.5.1008 | Anders |
LineStatusCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.10.2.3 | Binding: |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
Lopend | LNP | LijnStatus | 2.16.840.1.113883.2.4.3.11.60.40.4.12.1 | Lopend |
Afgedopt | DOP | LijnStatus | 2.16.840.1.113883.2.4.3.11.60.40.4.12.1 | Afgedopt |
Heparineslot | HEP | LijnStatus | 2.16.840.1.113883.2.4.3.11.60.40.4.12.1 | Heparineslot |
Zoutspoelingslot | ZOU | LijnStatus | 2.16.840.1.113883.2.4.3.11.60.40.4.12.1 | Zoutspoelingslot |
Other | OTH | NullFlavor | 2.16.840.1.113883.5.1008 | Anders |
LumenLocationCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.10.2.2 | Binding: |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
Proximal | 40415009 | SNOMED CT | 2.16.840.1.113883.6.96 | Proximaal |
Medial | 255561001 | SNOMED CT | 2.16.840.1.113883.6.96 | Mediaal |
Distal | 46053002 | SNOMED CT | 2.16.840.1.113883.6.96 | Distaal |
This information model in other releases
- Release 2016, (Version 3.0)
- Release 2017, (Version 3.2)
- Prerelease 2018-2, (Version 3.2)
- Prerelease 2019-2, (Version 3.3)
- Release 2020, (Version 3.3)
- Prerelease 2021-2, (Version 3.4)
- Prerelease 2022-1, (Version 3.4)
- Prerelease 2023-1, (Version 3.5)
- Prerelease 2024-1, (Version 3.5)
Information model references
This information model refers to
- MedicalDevice-v1.2
- MedicationAdministration-v1.0
- NursingIntervention-v1.0
- PlannedCareActivityForTransfer-v1.2.1
This information model is used in
- --
Technical specifications in HL7v3 CDA and HL7 FHIR
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
- HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
- HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
Downloads
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Registratie aan de bron publication 2015 including errata dd. 16-07-2015
Conditions for use are located on the mainpage
This page is generated on 24/12/2018 12:35:52 with ZibExtraction v. 3.0.6932.1989