O2Saturation-v3.1(2017EN): verschil tussen versies

Uit Zorginformatiebouwstenen
Naar navigatie springen Naar zoeken springen
Update bot (overleg | bijdragen)
Geen bewerkingssamenvatting
Update bot (overleg | bijdragen)
Geen bewerkingssamenvatting
 
Regel 127: Regel 127:
==Information Model==
==Information Model==
<BR>
<BR>
<imagemap> Bestand:O2Saturation-v3.1Model(EN).png | center  
<imagemap> Bestand:O2Saturation-v3.1Model(2017EN).png | center  
rect 356 244 493 314 [[#9454]]
rect 356 244 493 314 [[#9454]]
rect 356 59 493 129 [[#9452]]
rect 356 59 493 129 [[#9452]]
Regel 238: Regel 238:
The information in this wikipage is based on<!--ftInfoBase--> Release 2017 <BR>
The information in this wikipage is based on<!--ftInfoBase--> Release 2017 <BR>
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR>
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR>
This page is generated on 19/12/2018 18:33:05 with ZibExtraction v. 3.0.6927.32850<!--ftDate--> <BR>
This page is generated on 21/12/2018 14:10:56 with ZibExtraction v. 3.0.6929.24609<!--ftDate--> <BR>
-----
-----
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2017(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2017(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div>
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2017(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2017(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div>

Huidige versie van 24 dec 2018 om 13:04


Attention!! This is not the most recent version of this information model. You can find the most recent version ''here''.

General information

Name: nl.zorg.O2Saturation
Version: 3.1
HCIM Status:Final
Release: 2017
Release status: Published
Release date: 31-12-2017


Back to HCIM list

Metadata

DCM::CoderList Kerngroep Registratie aan de Bron
DCM::ContactInformation.Address *
DCM::ContactInformation.Name *
DCM::ContactInformation.Telecom *
DCM::ContentAuthorList Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron
DCM::CreationDate 29-11-2012
DCM::DeprecatedDate
DCM::DescriptionLanguage nl
DCM::EndorsingAuthority.Address
DCM::EndorsingAuthority.Name PM
DCM::EndorsingAuthority.Telecom
DCM::Id 2.16.840.1.113883.2.4.3.11.60.40.3.12.10
DCM::KeywordList zuurstofsaturatie, vitale parameters, saturatie
DCM::LifecycleStatus Final
DCM::ModelerList Kerngroep Registratie aan de Bron
DCM::Name nl.zorg.O2Saturatie
DCM::PublicationDate 31-12-2017
DCM::PublicationStatus Published
DCM::ReviewerList Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron
DCM::RevisionDate 31-12-2017
DCM::Superseeds nl.zorg.O2Saturatie-v3.0
DCM::Version 3.1
HCIM::PublicationLanguage EN

Revision History

Concept

Arterial oxygen saturation, also referred to as saturation, is an indicator for the amount of oxygen bound to the hemoglobin in the red blood cells of the arteries. The measurement is usually carried out as a transcutaneous measurement with a blood oxygen monitor or pulse oximeter. The saturation level is expressed as a percentage and should be over 95% in healthy people.

Purpose

Measuring and monitoring oxygen saturation is done to monitor the oxygenation, or the amount of bound oxygen in the arterial blood.

Information Model


#9454#9452#9455#9453#9451


Type Id Concept Card. Definition DefinitionCode Reference
NL-CM:12.10.1 O2Saturation Root concept of the O2Saturation information model. This root concept contains all data elements of the O2Saturation information model.
NL-CM:12.10.2 SpO2Value 1 The element contains the value of the indirect, peripheral measured O2 saturation.

The O2 saturation gives a percentage expressing the extent to which the blood’s hemoglobin is saturated with oxygen, the ratio of oxygen-saturated hemoglobin to hemoglobin. The measurement is done in places where sufficient light can get through the skin, such as a finger, toe or earlobe.

59408-5 Oxygen saturation in Arterial blood by Pulse oximetry
NL-CM:12.10.3 O2SaturationDateTime 1 The moment (date and time) of the SpO2 measurement.
NL-CM:12.10.4 Comment 0..1 Comment on the saturation measurement.
48767-8 Annotation comment
NL-CM:12.10.5 ExtraOxygenAdministration 0..1 Indication stating whether the measurement was done in a situation in which extra oxygen was administered.

Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page

Example Instances

Only available in Dutch

O2SaturatieDatumTijd SpO2Waarde ExtraZuurstofToediening Toelichting
08-02-2013 6:43 92% Ja Stijgt snel bij aanspreken

References

1. openEHR-EHR-OBSERVATION.indirect_oximetry.v1[Online] Beschikbaar op: http://www.openehr.org/knowledge/ [Geraadpleegd: 19 december 2014].

This information model in other releases

Information model references

This information model refers to

--

This information model is used in

--

Technical specifications in HL7v3 CDA and HL7 FHIR

To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:

  • HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
  • HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR

Downloads

This information model is also available as pdf file or as spreadsheet

About this information

The information in this wikipage is based on Release 2017
Conditions for use are located on the mainpage
This page is generated on 21/12/2018 14:10:56 with ZibExtraction v. 3.0.6929.24609


Back to HCIM list