O2Saturation-v3.1(2017EN)

Uit Zorginformatiebouwstenen
Versie door Update bot (overleg | bijdragen) op 21 sep 2017 om 17:26 (Nieuwe pagina aangemaakt met '==General information== Name: '''nl.zorg.O2Saturation''' link=O2Saturatie-v3.1(2017NL)<BR> Version: '''3.1''' <br> HCIM Status:Final<br> Publ...')
(wijz) ← Oudere versie | Huidige versie (wijz) | Nieuwere versie → (wijz)
Naar navigatie springen Naar zoeken springen

General information

Name: nl.zorg.O2Saturation
Version: 3.1
HCIM Status:Final
Publication: 2017
Release status: Prepublished
Publication date: 04-09-2017


Back to HCIM list

Metadata

DCM::CoderList Kerngroep Registratie aan de Bron
DCM::ContactInformation.Address *
DCM::ContactInformation.Name *
DCM::ContactInformation.Telecom *
DCM::ContentAuthorList Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron
DCM::CreationDate 29-11-2012
DCM::DeprecatedDate
DCM::DescriptionLanguage nl
DCM::EndorsingAuthority.Address
DCM::EndorsingAuthority.Name PM
DCM::EndorsingAuthority.Telecom
DCM::Id 2.16.840.1.113883.2.4.3.11.60.40.3.12.10
DCM::KeywordList zuurstofsaturatie, vitale parameters, saturatie
DCM::LifecycleStatus Final
DCM::ModelerList Kerngroep Registratie aan de Bron
DCM::Name nl.zorg.O2Saturatie
DCM::PublicationDate 04-09-2017
DCM::PublicationStatus Prepublished
DCM::ReviewerList Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron
DCM::RevisionDate 04-09-2017
DCM::Superseeds nl.zorg.O2Saturatie-v3.0
DCM::Version 3.1
HCIM::PublicationLanguage EN

Revision History

Concept

Arterial oxygen saturation, also referred to as saturation, is an indicator for the amount of oxygen bound to the hemoglobin in the red blood cells of the arteries. The measurement is usually carried out as a transcutaneous measurement with a blood oxygen monitor or pulse oximeter. The saturation level is expressed as a percentage and should be over 95% in healthy people.

Purpose

Measuring and monitoring oxygen saturation is done to monitor the oxygenation, or the amount of bound oxygen in the arterial blood.

Information Model



Type Id Concept Card. Definition DefinitionCode Reference
NL-CM:12.10.1 O2Saturation Root concept of the O2Saturation information model. This root concept contains all data elements of the O2Saturation information model.
NL-CM:12.10.2 SpO2Value 1 The element contains the value of the indirect, peripheral measured O2 saturation.

The O2 saturation gives a percentage expressing the extent to which the blood’s hemoglobin is saturated with oxygen, the ratio of oxygen-saturated hemoglobin to hemoglobin. The measurement is done in places where sufficient light can get through the skin, such as a finger, toe or earlobe.

59408-5 Oxygen saturation in Arterial blood by Pulse oximetry
NL-CM:12.10.3 O2SaturationDateTime 1 The moment (date and time) of the SpO2 measurement.
NL-CM:12.10.4 Comment 0..1 Comment on the saturation measurement.
48767-8 Annotation comment
NL-CM:12.10.5 ExtraOxygenAdministration 0..1 Indication stating whether the measurement was done in a situation in which extra oxygen was administered.

Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page

Example Instances

Only available in Dutch

O2SaturatieDatumTijd SpO2Waarde ExtraZuurstofToediening Toelichting
08-02-2013 6:43 92% Ja Stijgt snel bij aanspreken

References

1. openEHR-EHR-OBSERVATION.indirect_oximetry.v1[Online] Beschikbaar op: http://www.openehr.org/knowledge/ [Geraadpleegd: 19 december 2014].

More on this information model

More technical information and HL7/XML documentation you can find on the Nictiz Art-Decor page about this information model[1]
This information model is also available as pdf file or as spreadsheet

About this information

The information in this wikipage is based on Prerelease 2017 #1
Conditions for use are located on the mainpage
This page is generated on 21/09/2017 13:51:37