HeadCircumference-v1.0(2017EN)

Uit Zorginformatiebouwstenen
Versie door Update bot (overleg | bijdragen) op 20 feb 2018 om 10:05 (Copy of)
(wijz) ← Oudere versie | Huidige versie (wijz) | Nieuwere versie → (wijz)
Naar navigatie springen Naar zoeken springen

General information

Name: nl.zorg.HeadCircumference NL.png
Version: 1.0
HCIM Status:Final
Release: 2017
Release status: Prepublished
Release date: 04-09-2017


Back 16.png Back to HCIM list

Metadata

DCM::CoderList Werkgroep RadB Verpleegkundige Gegevens
DCM::ContactInformation.Address *
DCM::ContactInformation.Name *
DCM::ContactInformation.Telecom *
DCM::ContentAuthorList Werkgroep RadB Verpleegkundige Gegevens
DCM::CreationDate 11-10-2016
DCM::DeprecatedDate
DCM::DescriptionLanguage nl
DCM::EndorsingAuthority.Address
DCM::EndorsingAuthority.Name
DCM::EndorsingAuthority.Telecom
DCM::Id 2.16.840.1.113883.2.4.3.11.60.40.3.12.14
DCM::KeywordList Schedelomvang, hoofdomtrek
DCM::LifecycleStatus Final
DCM::ModelerList Werkgroep RadB Verpleegkundige Gegevens
DCM::Name nl.zorg.Schedelomvang
DCM::PublicationDate 04-09-2017
DCM::PublicationStatus Prepublished
DCM::ReviewerList Projectgroep RadB Verpleegkundige Gegevens & Kerngroep Registratie aan de Bron
DCM::RevisionDate 04-09-2017
DCM::Superseeds
DCM::Version 1.0
HCIM::PublicationLanguage EN

Revision History

Only available in Dutch

Publicatieversie 1.0 (04-09-2017) .

Concept

The head circumference is the size of the head as measured around the head.

Purpose

The head circumference can provide insight into the growth of a(n unborn) child. There may also be a smaller (microcephaly) or larger (macrocephaly) head circumference than average, which can indicate certain diseases or syndromes.

Evidence Base

The definitions of the concepts were (partly) based on the guidelines Fetal Growth Retardation of the NVOG and PTEN Hamartoma Tumor Syndrome by the VKGN.

Patient Population

The HeadCircumference information model is meant for all patients, including unborn children.

Information Model


#12027#12029#12028#12026#12131#HeadCircumferenceMeasuringMethodCodelistHeadCircumference-v1.0Model(EN).png


Type Id Concept Card. Definition DefinitionCode Reference
Block.png NL-CM:12.14.1 Arrowdown.pngHeadCircumference Root concept of the HeadCircumference information model. This root concept contains all data elements of the HeadCircumference information model.
ST.png NL-CM:12.14.4 Arrowright.pngComment 0..1 Comment on the head circumference.
48767-8 Annotation comment
TS.png NL-CM:12.14.2 Arrowright.pngHeadCircumferenceDate 1 The date on which the head circumference was measured.
PQ.png NL-CM:12.14.3 Arrowright.pngHeadCircumferenceMeasurement 1 The value of the head circumference as measured in centimeters (cm).
363812007 Head circumference
CD.png NL-CM:12.14.5 Arrowright.pngHeadCircumferenceMeasuringMethod 0..1 There are different methods to measure the head circumference: prenatal measurement using ultrasound or postnatal measurement using a measuring tape by measuring from the backside of the head (occiput) to above the eyes (supraorbital).
56792006 Measurement of skull circumference
List2.png HeadCircumferenceMeasuringMethodCodelist

Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page List2.png

Example Instances

Only available in Dutch

Schedelomvang
SchedelomvangWaarde 41 cm
SchedelomvangDatumTijd 19-12-2016
Toelichting Gemeten bij 3 maanden

Valuesets

HeadCircumferenceMeasuringMethodCodelist

Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.12.14.1
Conceptname Conceptcode Codesystem name Codesystem OID Description
Measurement of skull circumference with measuring tape 31551000146109 SNOMED CT 2.16.840.1.113883.6.96 Meten van schedelomvang m.b.v. meetlint
Ultrasound measurement of skull circumference 31561000146107 SNOMED CT 2.16.840.1.113883.6.96 Meten van schedelomvang m.b.v. echografisch onderzoek


This information model in other releases

---

More on this information model

To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:

  • HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment Artdecor.jpg
  • HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR Fhir.png

This information model is also available as pdf file PDF.png or as spreadsheet Xlsx.png

About this information

The information in this wikipage is based on Prerelease 2017 #1
Conditions for use are located on the mainpage List2.png
This page is generated on 30/11/2017 13:25:23


Back 16.png Back to HCIM list