Range-v1.0.1(2020EN): verschil tussen versies
(Nieuwe pagina aangemaakt met '<!-- Hieronder wordt een transclude page aangeroepen --> {{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.20.1(EN)|1|Range-v1.0.1(2020EN)}} <!-- Tot hier de transclu...') |
Geen bewerkingssamenvatting |
||
Regel 181: | Regel 181: | ||
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro--> | Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro--> | ||
<ul> | <ul> | ||
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2020bbr-?id=2.16.840.1.113883.2.4.3.11.60. | <li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2020bbr-?id=2.16.840.1.113883.2.4.3.11.60.121.4.2.20.1&effectiveDate=2020-09-01T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li> | ||
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2020}}</li> | <li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2020}}</li> | ||
</ul> | </ul> | ||
Regel 190: | Regel 190: | ||
SNOMED CT and LOINC codes are based on: | SNOMED CT and LOINC codes are based on: | ||
<ul> | <ul> | ||
<li>SNOMED Clinical Terms version: | <li>SNOMED Clinical Terms version: 20200731 [R] (July 2020 Release)</li> | ||
<li>LOINC version 2.67</li> | <li>LOINC version 2.67</li> | ||
</ul> | </ul> | ||
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR> | Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR> | ||
This page is generated on | This page is generated on 29/09/2020 21:20:35 with ZibExtraction v. 4.0.7577.31095<!--ftDate--> <BR> | ||
----- | ----- | ||
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2020(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2020(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2020(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2020(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> |
Huidige versie van 29 sep 2020 om 21:19
General information
Name: nl.zorg.part.Range
Version: 1.0.1
HCIM Status:Final
Release: 2020
Release status: Published
Release date: 01-09-2020
Metadata
DCM::CoderList | Kerngroep Registratie aan de Bron |
DCM::ContactInformation.Address | |
DCM::ContactInformation.Name | |
DCM::ContactInformation.Telecom | |
DCM::ContentAuthorList | Kerngroep Registratie aan de Bron |
DCM::CreationDate | 10/01/2017 |
DCM::DeprecatedDate | |
DCM::DescriptionLanguage | nl |
DCM::EndorsingAuthority.Address | |
DCM::EndorsingAuthority.Name | |
DCM::EndorsingAuthority.Telecom | |
DCM::Id | 2.16.840.1.113883.2.4.3.11.60.40.3.20.1 |
DCM::KeywordList | |
DCM::LifecycleStatus | Final |
DCM::ModelerList | Kerngroep Registratie aan de Bron |
DCM::Name | nl.zorg.part.Bereik |
DCM::PublicationDate | 01-09-2020 |
DCM::PublicationStatus | Published |
DCM::ReviewerList | Kerngroep Registratie aan de Bron |
DCM::RevisionDate | 31-12-2017 |
DCM::Supersedes | nl.zorg.part.Bereik-v1.0 |
DCM::Version | 1.0.1 |
HCIM::PublicationLanguage | EN |
Revision History
Only available in Dutch
Publicatieversie 1.0 (04-09-2017)
Publicatieversie 1.0.1 (06-07-2019)
ZIB-805 | Bereik invariant toevoegen in UML modellering |
Concept
The range gives either a fixed value or a minimum and maximum value a quantity can take on.
This is a partial information model.
Purpose
The range is used to limit the value a quantity can take on.
Information Model
Type | Id | Concept | Card. | Definition | DefinitionCode | Reference | |||||
NL-CM:20.1.1 | Range | Root concept of the Range partial information model. This root concept contains all data elements of the Range partial information model. | |||||||||
NL-CM:20.1.2 | minimumValue | 0..1 | The minimal value of the range | ||||||||
NL-CM:20.1.3 | maximumValue | 0..1 | The maximum value of the range | ||||||||
NL-CM:20.1.4 | nominalValue | 0..1 | The nominal value of the quantity. This element can not be used in combination with a minimum and maximum value |
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
Bereik | |
Minimum waarde | 5 stuks |
Maximum waarde | 10 stuks |
Nominale waarde |
Bereik | |
Minimum waarde | |
Maximum waarde | |
Nominale waarde | 2 / per dag |
This information model in other releases
- Release 2017, (Version 1.0)
- Prerelease 2018-2, (Version 1.0)
- Prerelease 2019-2, (Version 1.0.1)
- Prerelease 2021-2, (Version 1.0.1)
- Prerelease 2022-1, (Version 1.0.1)
- Prerelease 2023-1, (Version 1.0.1)
- Prerelease 2024-1, (Version 1.0.1)
Information model references
This information model refers to
- --
This information model is used in
Technical specifications in HL7v3 CDA and HL7 FHIR
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
- HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
- HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
Downloads
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Release 2020
SNOMED CT and LOINC codes are based on:
- SNOMED Clinical Terms version: 20200731 [R] (July 2020 Release)
- LOINC version 2.67
Conditions for use are located on the mainpage
This page is generated on 29/09/2020 21:20:35 with ZibExtraction v. 4.0.7577.31095