VisualFunction-v3.1(2018EN): verschil tussen versies
(Nieuwe pagina aangemaakt met '<!-- Hieronder wordt een transclude page aangeroepen --> {{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.4.16(EN)|1|VisualFunction-v3.1(2018EN)}} <!-- Tot hier de t...') |
Geen bewerkingssamenvatting |
||
Regel 8: | Regel 8: | ||
Release<!--hdPublication-->: '''2018''' <br> | Release<!--hdPublication-->: '''2018''' <br> | ||
Release status<!--hdPublicationStatus-->: Prepublished<br> | Release status<!--hdPublicationStatus-->: Prepublished<br> | ||
Release date<!--hdPublicationDate-->: | Release date<!--hdPublicationDate-->: 26-02-2019 | ||
----- | ----- | ||
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2018(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2018(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2018(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2018(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> | ||
Regel 47: | Regel 47: | ||
|style="width:250px; "|DCM::Name||nl.zorg.FunctieZien | |style="width:250px; "|DCM::Name||nl.zorg.FunctieZien | ||
|- | |- | ||
|style="width:250px; "|DCM::PublicationDate|| | |style="width:250px; "|DCM::PublicationDate||26-02-2019 | ||
|- | |- | ||
|style="width:250px; "|DCM::PublicationStatus||Prepublished | |style="width:250px; "|DCM::PublicationStatus||Prepublished | ||
Regel 96: | Regel 96: | ||
==Information Model== | ==Information Model== | ||
<BR> | <BR> | ||
<imagemap> Bestand:VisualFunction-v3.1Model( | <imagemap> Bestand:VisualFunction-v3.1Model(2018EN).png | center | ||
rect | rect 498 43 659 113 [[#9286]] | ||
rect | rect 80 323 226 393 [[#9281]] | ||
rect | rect 41 432 265 482 [[#VisualAidTypeCodelist]] | ||
rect | rect 271 325 417 395 [[MedicalDevice-v3.2(2018EN)]] | ||
rect | rect 498 275 659 325 [[#VisualFunctionCodelist]] | ||
rect | rect 498 166 659 236 [[#9278]] | ||
rect | rect 292 154 438 234 [[#9279]] | ||
desc none | desc none | ||
</imagemap> | </imagemap> | ||
Regel 150: | Regel 150: | ||
{| | {| | ||
|- | |- | ||
|[[Bestand: block.png | link=MedicalDevice-v3. | |[[Bestand: block.png | link=MedicalDevice-v3.2(2018EN)]]||[[MedicalDevice-v3.2(2018EN) |MedicalDevice]] | ||
|} | |} | ||
|-style="vertical-align:top; background-color: transparent; " | |-style="vertical-align:top; background-color: transparent; " | ||
Regel 234: | Regel 234: | ||
|leesbril | |leesbril | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|<span title = "Bril" >Eyeglasses</span> | |<span title = "Bril">Eyeglasses</span> | ||
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=50121007 50121007] | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=50121007 50121007] | ||
|SNOMED CT | |SNOMED CT | ||
Regel 240: | Regel 240: | ||
|bril | |bril | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|<span title = "Contactlens" >Contact lenses</span> | |<span title = "Contactlens">Contact lenses</span> | ||
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=57368009 57368009] | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=57368009 57368009] | ||
|SNOMED CT | |SNOMED CT | ||
Regel 277: | Regel 277: | ||
|Geen visuele stoornis | |Geen visuele stoornis | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|<span title = "Verlies van gezichtsvermogen" >Visual impairment</span> | |<span title = "Verlies van gezichtsvermogen">Visual impairment</span> | ||
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=397540003 397540003] | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=397540003 397540003] | ||
|SNOMED CT | |SNOMED CT | ||
Regel 283: | Regel 283: | ||
|Verminderd gezichtsvermogen | |Verminderd gezichtsvermogen | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|<span title = "Bilaterale blind- of slechtziendheid" >Blind or low vision - both eyes</span> | |<span title = "Bilaterale blind- of slechtziendheid">Blind or low vision - both eyes</span> | ||
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=267727004 267727004] | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=267727004 267727004] | ||
|SNOMED CT | |SNOMED CT | ||
Regel 296: | Regel 296: | ||
==Information model references<!--ftReferences-->== | ==Information model references<!--ftReferences-->== | ||
====This information model refers to<!--ftRefersTo-->==== | ====This information model refers to<!--ftRefersTo-->==== | ||
*[[MedicalDevice-v3. | *[[MedicalDevice-v3.2(2018EN)|MedicalDevice-v3.2]] | ||
====This | ====This information model is used in<!--ftReferredBy-->==== | ||
:-- | :-- | ||
==Technical specifications in HL7v3 CDA and HL7 FHIR<!--ftHeader-->== | ==Technical specifications in HL7v3 CDA and HL7 FHIR<!--ftHeader-->== | ||
Regel 303: | Regel 303: | ||
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro--> | Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro--> | ||
<ul> | <ul> | ||
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2018bbr-?id=2.16.840.1.113883.2.4.3.11.60.8.4.2.4.16&effectiveDate= | <li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2018bbr-?id=2.16.840.1.113883.2.4.3.11.60.8.4.2.4.16&effectiveDate=2019-02-26T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li> | ||
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2018}}</li> | <li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2018}}</li> | ||
</ul> | </ul> | ||
Regel 309: | Regel 309: | ||
This information model is also available as [[Media:nl.zorg.VisualFunction-v3.1(2018EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.zorg.VisualFunction-v3.1(2018EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]<!--ftDownloads--> | This information model is also available as [[Media:nl.zorg.VisualFunction-v3.1(2018EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.zorg.VisualFunction-v3.1(2018EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]<!--ftDownloads--> | ||
==About this information<!--ftHeader2-->== | ==About this information<!--ftHeader2-->== | ||
The information in this wikipage is based on<!--ftInfoBase--> Prerelease 2018 | The information in this wikipage is based on<!--ftInfoBase--> Prerelease 2018-2 <BR> | ||
SNOMED CT and LOINC codes are based on: | SNOMED CT and LOINC codes are based on: | ||
<ul> | <ul> | ||
Regel 316: | Regel 316: | ||
</ul> | </ul> | ||
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR> | Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR> | ||
This page is generated on | This page is generated on 12/03/2019 17:16:50 with ZibExtraction v. 3.0.7010.25883<!--ftDate--> <BR> | ||
----- | ----- | ||
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2018(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2018(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2018(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2018(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> |
Huidige versie van 13 mrt 2019 om 01:53
General information
Name: nl.zorg.VisualFunction
Version: 3.1
HCIM Status:Final
Release: 2018
Release status: Prepublished
Release date: 26-02-2019
Metadata
DCM::CoderList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::ContactInformation.Address | * |
DCM::ContactInformation.Name | * |
DCM::ContactInformation.Telecom | * |
DCM::ContentAuthorList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::CreationDate | 4-4-2014 |
DCM::DeprecatedDate | |
DCM::DescriptionLanguage | nl |
DCM::EndorsingAuthority.Address | |
DCM::EndorsingAuthority.Name | PM |
DCM::EndorsingAuthority.Telecom | |
DCM::Id | 2.16.840.1.113883.2.4.3.11.60.40.3.4.16 |
DCM::KeywordList | Zien, lagere visuele functies, gezichtsvermogen |
DCM::LifecycleStatus | Final |
DCM::ModelerList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::Name | nl.zorg.FunctieZien |
DCM::PublicationDate | 26-02-2019 |
DCM::PublicationStatus | Prepublished |
DCM::ReviewerList | Projectgroep RadB Verpleegkundige Gegevens & Kerngroep Registratie aan de Bron |
DCM::RevisionDate | 31-12-2017 |
DCM::Superseeds | nl.zorg.FunctieZien-v3.0 |
DCM::Version | 3.1 |
HCIM::PublicationLanguage | EN |
Revision History
Only available in Dutch
Publicatieversie 1.0 (01-07-2015)
Publicatieversie 3.0 (01-05-2016)
Publicatieversie 3.1 (04-09-2017)
ZIB-530 | Verwijzingen naar de bouwsteen Verpleegkundige Interventie verwijderd |
ZIB-531 | Vervangen 5-punts ICF schaal door 3-punts SNOMED CT schaal voor beperkingen en stoornissen |
.
Concept
Sight is the ability to observe lit objects, with the goal of orienting yourself on objects and people in a lit environment. This pertains to observing the light stimuli, and not processing them in the brain.
A sight disorder can lead to things including orientation problems.
Purpose
Information on visual function disorders is important in patient care and treatment and particularly in the communication with the patient. Based on this information, healthcare can be adjusted to the patient’s limitations if needed.
Evidence Base
The definitions of the concepts were (partially) taken from the ICNP definitions.
Information Model
Type | Id | Concept | Card. | Definition | DefinitionCode | Reference | ||||||||
NL-CM:4.16.1 | VisualFunction | Root concept of the VisualFunction information model. This concept contains all data elements of the VisualFunction information model. | ||||||||||||
NL-CM:4.16.3 | VisualFunction | 1 | The ability to see as a result of response to stimuli of visual organs |
|
| |||||||||
NL-CM:4.16.4 | VisualAid:MedicalDevice | 0..* | The medical aids used to support the visual function. |
|
| |||||||||
NL-CM:10.1.3 | ProductType | The type of product used to help the patient see. |
| |||||||||||
NL-CM:4.16.2 | Comment | 0..1 | A comment on the visual function. |
|
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
FunctieZien | |
VisueleFunctie | Verminderd gezichtsvermogen |
ZienHulpmiddel | |
ProductType | Leesbril |
Toelichting | Ziet met linkeroog slechter dan met het rechteroog. |
References
1. International Classification of Functioning Disability and Health (ICF) [Online] Beschikbaar op:http:/www.rivm.nl/who-fic/icf.htm [Geraadpleegd: 13 februari 2015]
Valuesets
VisualAidTypeCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.4.16.2 | Binding: Extensible |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
geen | 0 | eCare codes | 2.16.840.1.113883.2.4.3.11.22.218 | geen visuele hulpmiddelen |
Single vision reading glasses | 423013001 | SNOMED CT | 2.16.840.1.113883.6.96 | leesbril |
Eyeglasses | 50121007 | SNOMED CT | 2.16.840.1.113883.6.96 | bril |
Contact lenses | 57368009 | SNOMED CT | 2.16.840.1.113883.6.96 | contactlenzen |
Magnifier | 264865009 | SNOMED CT | 2.16.840.1.113883.6.96 | loep |
other | OTH | NullFlavor | 2.16.840.1.113883.5.1008 | anders |
VisualFunctionCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.4.16.1 | Binding: Required |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
Normal vision | 45089002 | SNOMED CT | 2.16.840.1.113883.6.96 | Geen visuele stoornis |
Visual impairment | 397540003 | SNOMED CT | 2.16.840.1.113883.6.96 | Verminderd gezichtsvermogen |
Blind or low vision - both eyes | 267727004 | SNOMED CT | 2.16.840.1.113883.6.96 | (Vrijwel) blind |
This information model in other releases
- Release 2015, (Version 1.0)
- Release 2016, (Version 3.0)
- Release 2017, (Version 3.1)
- Prerelease 2019-2, (Version 3.1)
- Release 2020, (Version 3.1)
- Prerelease 2021-2, (Version 3.3)
- Prerelease 2022-1, (Version 3.3)
- Prerelease 2023-1, (Version 3.4)
- Prerelease 2024-1, (Version 3.4)
Information model references
This information model refers to
This information model is used in
- --
Technical specifications in HL7v3 CDA and HL7 FHIR
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
- HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
- HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
Downloads
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Prerelease 2018-2
SNOMED CT and LOINC codes are based on:
- SNOMED Clinical Terms version: 20180731 [R] (July 2018 Release)
- LOINC version 2.64
Conditions for use are located on the mainpage
This page is generated on 12/03/2019 17:16:50 with ZibExtraction v. 3.0.7010.25883