LaboratoryTestResultForTransfer-v3.0(2016EN): verschil tussen versies

Uit Zorginformatiebouwstenen
Naar navigatie springen Naar zoeken springen
Update bot (overleg | bijdragen)
Geen bewerkingssamenvatting
Update bot (overleg | bijdragen)
Copy of
Regel 775: Regel 775:
<ul>
<ul>
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2016bbr-?id=2.16.840.1.113883.2.4.3.11.60.6.4.2.13.1&effectiveDate=2016-05-01T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li>
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2016bbr-?id=2.16.840.1.113883.2.4.3.11.60.6.4.2.13.1&effectiveDate=2016-05-01T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li>
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR [https://simplifier.net/NictizSTU3/~resources?text=zib&category=StructureDefinition [[File:fhir.png|link=]]]</li>
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR [https://simplifier.net/NictizSTU3/~resources?text=zib&category=Profile [[File:fhir.png|link=]]]</li>
</ul>
</ul>
This information model is also available as [[Media:nl.zorg.LaboratoryTestResultForTransfer-v3.0(2016EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.zorg.LaboratoryTestResultForTransfer-v3.0(2016EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]
This information model is also available as [[Media:nl.zorg.LaboratoryTestResultForTransfer-v3.0(2016EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.zorg.LaboratoryTestResultForTransfer-v3.0(2016EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]

Versie van 20 feb 2018 11:05

General information

Name: nl.zorg.LaboratoryTestResultForTransfer
Version: 3.0
HCIM Status:Final
Release: 2016
Release status: Published
Release date: 1-5-2016


Back to HCIM list

Metadata

DCM::CoderList Kerngroep Registratie aan de Bron
DCM::ContactInformation.Address *
DCM::ContactInformation.Name *
DCM::ContactInformation.Telecom *
DCM::ContentAuthorList Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron
DCM::CreationDate 7-6-2012
DCM::DeprecatedDate
DCM::DescriptionLanguage nl
DCM::EndorsingAuthority.Address
DCM::EndorsingAuthority.Name PM
DCM::EndorsingAuthority.Telecom
DCM::Id 2.16.840.1.113883.2.4.3.11.60.40.3.13.1
DCM::KeywordList laboratorium uitslag, lab, laboratorium bepaling
DCM::LifecycleStatus Final
DCM::ModelerList Kerngroep Registratie aan de Bron
DCM::Name nl.zorg.OverdrachtLaboratoriumUitslag
DCM::PublicationDate 1-5-2016
DCM::PublicationStatus Published
DCM::ReviewerList Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron
DCM::RevisionDate 25-8-2015
DCM::Superseeds nl.nfu.OverdrachtLaboratoriumUitslag-v1.2.2
DCM::Version 3.0
HCIM::PublicationLanguage EN

Revision History

Concept

A laboratory result describes the result of a laboratory analysis.
In addition to the results of tests with a singular result, the results of more complex tests with multiple results or a ‘panel’ can also be recorded.

Purpose

Laboratory tests are done for the purpose of diagnosing and preventing disease and follow-up on the effects of treatment.

Evidence Base

There are two information models for recording laboratory test results: TextResultTransfer and LaboratoryResultTransfer.

In the case of laboratory test results, it is difficult to clearly indicate exactly when to use this information model and when to use the TextResultTransfer information model.
In general, laboratory tests resulting in a value (7.1 mmol/L), ordinal number (++ from series to ++++) or a quantitative result (Low) are recorded using this information model. The TextResultTransfer information model is better suited for textual results that are more descriptive in nature and which are longer than just a few words. Both types of tests occur in almost all laboratories.
The applicability of the aforementioned information models is not determined by the kind of lab but by the kind of result.

In developing the information model, the definitions were used from the data set and coding choices from the IHE/Nictiz e-Lab program.
The now determined information model is a subset of the e-Lab data set, provided that the detailing that is less relevant to the general transfer use case was left out. If this information is required, it can be entered in the comments field.

Information Model


#ResultStatusCodelist#TestCodelist#10897#10919#ResultTypeCodelist#10899#10911#10896#10892#10895
#TestNameCodelist#TestMethodCodelist#ResultFlagsCodelist#10913#10910#10911#10909#10903#10905#10907#10915
#DrawingProcedureCodelist#SpecimenMaterialCodelist#10919#10918#10920#10921#10916#10917


Type Id Concept Card. Definition DefinitionCode Reference
NL-CM:13.1.1 LaboratoryTestResult Root concept of the LaboratoryTestResultTransfer information model. This root concept contains all data elements of the Laboratory TestResultTransfer information model.
NL-CM:13.1.2 Specimen 1 Container of the Specimen concept. This container contains all data elements of the Specimen concept.
NL-CM:13.1.15 SpecimenNumber 0..* Identification number of the material obtained, as a reference for inquiries to the source organization. In a transmural setting, this number will consist of a specimen number including the identification of the issuing organization, to be unique outside of the borders of an organization.
NL-CM:13.1.16 SpecimenMaterial 1 SpecimenMaterial describes the material obtained. If the LOINC test code also implicitly describes a material, this element may not conflict with the description. If desired, this component can provide a more detailed description of the material: LOINC codes only contain the materials at a main level.

This is in line with the agreements made in the IHE/Nictiz program e-Lab.

If the test is carried out on derived material (such as plasma), this element will still contain the material drawn (in this case, blood). In this case, the LOINC code will generally refer to plasma.

SpecimenMaterialCodelist
NL-CM:13.1.17 DrawingDateTime 1 Time at which the material was drawn.
399445004 specimen collection date
NL-CM:13.1.18 DrawingProcedure 0..1 If relevant for the results, the method of obtaining the specimen can be entered as well.
DrawingProcedureCodelist
NL-CM:13.1.19 Explanation 0..1 Comments on administering the test, such as drawing material after a (glucose) stimulus or taking medicine.
48767-8 Annotation comment
NL-CM:13.1.3 LaboratoryTest 0..* Container of the LaboratoryTest concept. This container contains all data elements of the LaboratoryTest concept.
NL-CM:13.1.8 TestName 1 The TestName is the name of the executed test.
TestNameCodelist
NL-CM:13.1.9 TestMethod 0..1 The test method used to obtain the result.
TestMethodCodelist
NL-CM:13.1.13 TestDateTime 0..1 The date and if possible the time at which the test was carried out.
NL-CM:13.1.10 Result 1 The test result. Depending on the type of test, the result will consist of a value with a unit or a coded value (ordinal or nominal).
NL-CM:13.1.11 UpperReferenceLimit 0..1 The upper reference limit for the patient of the value measured in the test.
NL-CM:13.1.12 LowerReferenceLimit 0..1 The lower reference limit for the patient of the value measured with the test.
NL-CM:13.1.14 ResultFlags 0..* Attention codes indicating whether the result is above or below certain reference values.
ResultFlagsCodelist
NL-CM:13.1.4 Test 0..1 For laboratory tests comprising multiple subtests and often requested together as a whole, this concept contains the name of the compound request (often indicated as a ‘panel’, ‘battery’ or ‘cluster’). Examples include: blood gases and EBV serology.
TestCodelist
NL-CM:13.1.6 ResultStatus 0..1 The status of the laboratory test result.
ResultStatusCodelist
NL-CM:13.1.5 Explanation 0..1 Comments, such as a textual interpretation or advice accompanying the result, for example.
48767-8 Annotation comment
NL-CM:13.1.7 ResultType 1 The type of result defines the laboratory specialty under which the test is categorized.
ResultTypeCodelist

Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page

Example Instances

Only available in Dutch

LaboratoriumUitslag
Resultaat
Type
Resultaat
Status
Monster LaboratoriumTest
Monster
materiaal
Afname
DatumTijd
TestNaam Test
DatumTijd
Uitslag Referentie
Ondergrens
Referentie
Bovengrens
Resultaat
Vlaggen
Klinische chemie Definitief Bloed 12-06-2012 09:00 Natrium 12-06-2012 13:15 138 mmol/l 136 mmol/l 146 mmol/l
LaboratoriumUitslag
Resultaat
Type
Resultaat
Status
Monster LaboratoriumTest
Monster
materiaal
Afname
DatumTijd
TestNaam Test
DatumTijd
Uitslag Referentie
Ondergrens
Referentie
Bovengrens
Resultaat
Vlaggen
Klinische chemie Definitief Bloed 23-05-2012 08:08 Chloride 23-05-2012 12:00 109 mmol/l 99 mmol/l 108 mmol/l Boven referentie-
waarde
LaboratoriumUitslag
Resultaat
Type
Resultaat
Status
Monster LaboratoriumTest
Monster
materiaal
Afname
DatumTijd
TestNaam Test
DatumTijd
Uitslag Referentie
Ondergrens
Referentie
Bovengrens
Resultaat
Vlaggen
Virologie Definitief Bloed 16-01-2012 08:00 Hepatitis A IgM 16-01-2012 10:12 Negatief

References

1. Nederlandse Vereniging voor Medische Microbiologie (2010) ELab en EvT. [Online] Beschikbaar op: http://www.nvmm.nl/ict/vereniging/werkgroepen_commissies/elab-en-evt [Geraadpleegd: 23 juli 2014].

Valuesets

DrawingProcedureCodelist

Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.13.1.2
Conceptname Codesystem name Codesystem OID
SNOMED CT: <17636008 | specimen collection | SNOMED CT 2.16.840.1.113883.6.96

ResultFlagsCodelist

Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.13.1.7
Conceptname Conceptcode Codesystem name Codesystem OID Description
High H ObservationInterpretation 2.16.840.1.113883.5.83 Boven referentiewaarde
Low L ObservationInterpretation 2.16.840.1.113883.5.83 Onder referentiewaarde
Intermediate I ObservationInterpretation 2.16.840.1.113883.5.83 Variabel
Resistant R ObservationInterpretation 2.16.840.1.113883.5.83 Resistent
Susceptible S ObservationInterpretation 2.16.840.1.113883.5.83 Sensitief

ResultStatusCodelist

Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.13.1.8
Conceptname Conceptcode Codesystem name Codesystem OID Description
Pending pending ResultaatStatus 2.16.840.1.113883.2.4.3.11.60.40.4.16.1 Uitslag volgt
Preliminary preliminary ResultaatStatus 2.16.840.1.113883.2.4.3.11.60.40.4.16.1 Voorlopig
Final final ResultaatStatus 2.16.840.1.113883.2.4.3.11.60.40.4.16.1 Definitief
Appended appended ResultaatStatus 2.16.840.1.113883.2.4.3.11.60.40.4.16.1 Aanvullend
Corrected corrected ResultaatStatus 2.16.840.1.113883.2.4.3.11.60.40.4.16.1 Gecorrigeerd

ResultTypeCodelist

Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.13.1.1
Conceptname Conceptcode Codesystem name Codesystem OID Description
Hematology 252275004 SNOMED CT 2.16.840.1.113883.6.96 Hematologie
Chemistry 275711006 SNOMED CT 2.16.840.1.113883.6.96 Klinische chemie
Serology 68793005 SNOMED CT 2.16.840.1.113883.6.96 Serologie/ immunologie
Virology 395124008 SNOMED CT 2.16.840.1.113883.6.96 Virologie
Toxicology 314076009 SNOMED CT 2.16.840.1.113883.6.96 Toxicologie
Microbiology 19851009 SNOMED CT 2.16.840.1.113883.6.96 Microbiologie

SpecimenMaterialCodelist

Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.13.1.6
Conceptname Codesystem name Codesystem OID
SNOMED CT: <123038009 | specimen | SNOMED CT 2.16.840.1.113883.6.96

TestCodelist

Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.13.1.5
Conceptname Codesystem name Codesystem OID
Alle waarden LOINC 2.16.840.1.113883.6.1

TestMethodCodelist

Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.13.1.4
Conceptname Codesystem name Codesystem OID
Alle waarden SNOMED CT 2.16.840.1.113883.6.96

TestNameCodelist

Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.13.1.3
Conceptname Codesystem name Codesystem OID
Alle waarden LOINC 2.16.840.1.113883.6.1


This information model in other releases

More on this information model

To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:

  • HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
  • HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR

This information model is also available as pdf file or as spreadsheet

About this information

The information in this wikipage is based on Release summer 2016
Conditions for use are located on the mainpage
This page is generated on 24/01/2018 23:31:23


Back to HCIM list