<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2015bbr-?id=2.16.840.1.113883.2.4.3.11.60.5.4.2.13.3&effectiveDate=2015-09-08T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li> | <li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2015bbr-?id=2.16.840.1.113883.2.4.3.11.60.5.4.2.13.3&effectiveDate=2015-09-08T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li> | ||
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR [https://simplifier.net/NictizSTU3/~resources?text=zib&category= | <li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR [https://simplifier.net/NictizSTU3/~resources?text=zib&category=Profile [[File:fhir.png|link=]]]</li> | ||
</ul> | </ul> | ||
This information model is also available as [[Media:nl.nfu.GeneralMeasurement-v1.0(2015EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.nfu.GeneralMeasurement-v1.0(2015EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]] | This information model is also available as [[Media:nl.nfu.GeneralMeasurement-v1.0(2015EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.nfu.GeneralMeasurement-v1.0(2015EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]] |
Versie van 20 feb 2018 10:05
General information
Name: nl.nfu.GeneralMeasurement
Version: 1.0
HCIM Status:Final
Release: 2015
Release status: Published
Release date: 8-9-2015
Metadata
DCM::CoderList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::ContactInformation.Address | * |
DCM::ContactInformation.Name | * |
DCM::ContactInformation.Telecom | * |
DCM::ContentAuthorList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::CreationDate | 14-3-2014 |
DCM::DescriptionLanguage | nl |
DCM::EndorsingAuthority.Address | |
DCM::EndorsingAuthority.Name | NFU & V&VN |
DCM::EndorsingAuthority.Telecom | |
DCM::Id | 2.16.840.1.113883.2.4.3.11.60.40.3.13.3 |
DCM::KeywordList | Algemene meting |
DCM::LifecycleStatus | Final |
DCM::ModelerList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::Name | nl.nfu.AlgemeneMeting |
DCM::PublicationDate | 8-9-2015 |
DCM::PublicationStatus | Published |
DCM::ReviewerList | Projectgroep RadB Verpleegkundige Gegevens & Kerngroep Registratie aan de Bron |
DCM::RevisionDate | 8-9-2015 |
DCM::Superseeds | |
DCM::Version | 1.0 |
HCIM::PublicationLanguage | EN |
Revision History
Only available in Dutch
Publicatieversie 1.0 (01-07-2015).
Concept
A general measurement determines the result of a measurement or determination made for a patient. The building block is used to record the measurement results for which no specific building blocks have yet been formulated. The building block is not intended for laboratory determinations to be carried out on the material taken from the patient.
Purpose
The measurement and documentation of physiological observations are an important tool for evaluating a patient’s condition. This building block offers the option to record various relevant measurement values.
Information Model
Type | Id | Concept | Card. | Definition | DefinitionCode | Reference | |||||||
NL-CM:13.3.1 | GeneralMeasurement | Root concept of the GeneralMeasurement building block. This root concept contains all data elements of the GeneralMeasurement building block. | |||||||||||
NL-CM:13.3.2 | Test | 0..1 | A general measurement can contain multiple components. This concept contains the name and code of the entire measurement. The components are represented in one or more MeasurementResult concepts. |
| |||||||||
NL-CM:13.3.3 | ResultStatus | 0..1 | The status of the total measurement. |
| |||||||||
NL-CM:13.3.4 | Explanation | 0..1 | Comments such as an interpretation or advice accompanying the result. |
|
|||||||||
NL-CM:13.3.5 | MeasurementResult | 0..* | Container of the MeasurementResult concept. This container contains all data elements of the MeasurementResult concept. | ||||||||||
NL-CM:13.3.6 | MeasurementName | 1 | Description (name and code) of the measurement. |
| |||||||||
NL-CM:13.3.7 | ResultValue | 0..1 | The result of the measurement. Depending on the type of measurement, the result will consist of a value with a unit or a coded value (ordinal or nominal) or of a textual result. | ||||||||||
NL-CM:13.3.8 | MeasuringMethod | 0..1 | The test method used to obtain the result. |
| |||||||||
NL-CM:13.3.9 | ResultDateTime | 0..1 | Date and if possible the time at which the measurement was carried out. |
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
MeetUitslag | Toelichting | ResultaatStatus | ||
MetingNaam | UitslagWaarde | UitslagDatumTijd | ||
Delirium observatie screening (DOS) | 7 | 12-03-2014 | Waarschijnlijk delier | Definitief |
Valuesets
MeasurementNameCodelist
Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.13.3.2 |
Conceptname | Codesystem name | Codesystem OID |
Alle waarden | SNOMED CT | 2.16.840.1.113883.6.96 |
MeasuringMethodCodelist
Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.13.3.4 |
Conceptname | Codesystem name | Codesystem OID |
Alle waarden | SNOMED CT | 2.16.840.1.113883.6.96 |
ResultStatusCodelist
Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.13.3.1 |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
Pending | pending | ResultaatStatus | 2.16.840.1.113883.2.4.3.11.60.40.4.15.1 | Uitslag volgt |
Preliminary | preliminary | ResultaatStatus | 2.16.840.1.113883.2.4.3.11.60.40.4.15.1 | Voorlopig |
Final | final | ResultaatStatus | 2.16.840.1.113883.2.4.3.11.60.40.4.15.1 | Definitief |
Appended | appended | ResultaatStatus | 2.16.840.1.113883.2.4.3.11.60.40.4.15.1 | Aanvullend |
Corrected | corrected | ResultaatStatus | 2.16.840.1.113883.2.4.3.11.60.40.4.15.1 | Gecorrigeerd |
TestCodelist
Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.13.3.3 |
Conceptname | Codesystem name | Codesystem OID |
Alle waarden | SNOMED CT | 2.16.840.1.113883.6.96 |
This information model in other releases
More on this information model
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
- HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
- HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Registratie aan de bron publication 2015 including errata dd. 16-07-2015
Conditions for use are located on the mainpage
This page is generated on 24/01/2018 17:35:29