OutcomeOfCare-v1.0(2015EN): verschil tussen versies
Geen bewerkingssamenvatting |
Geen bewerkingssamenvatting |
||
Regel 78: | Regel 78: | ||
==Information Model== | ==Information Model== | ||
<BR> | <BR> | ||
<imagemap> Bestand:OutcomeOfCare-v1.0Model( | <imagemap> Bestand:OutcomeOfCare-v1.0Model(2015EN).png | center | ||
rect 390 94 490 174 [[#10313]] | rect 390 94 490 174 [[#10313]] | ||
rect 375 229 499 299 [[GeneralMeasurement-v1.0(2015EN)]] | rect 375 229 499 299 [[GeneralMeasurement-v1.0(2015EN)]] | ||
Regel 209: | Regel 209: | ||
The information in this wikipage is based on<!--ftInfoBase--> ''Registratie aan de bron'' publication 2015 including errata dd. 16-07-2015 <BR> | The information in this wikipage is based on<!--ftInfoBase--> ''Registratie aan de bron'' publication 2015 including errata dd. 16-07-2015 <BR> | ||
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR> | Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR> | ||
This page is generated on | This page is generated on 24/12/2018 12:36:53 with ZibExtraction v. 3.0.6932.1989<!--ftDate--> <BR> | ||
----- | ----- | ||
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2015(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2015(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2015(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2015(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> |
Huidige versie van 24 dec 2018 om 12:15
General information
Name: nl.nfu.OutcomeOfCare
Version: 1.0
HCIM Status:Final
Release: 2015
Release status: Published
Release date: 8-9-2015
Metadata
DCM::CoderList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::ContactInformation.Address | * |
DCM::ContactInformation.Name | * |
DCM::ContactInformation.Telecom | * |
DCM::ContentAuthorList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::CreationDate | 8-9-2014 |
DCM::DeprecatedDate | |
DCM::DescriptionLanguage | nl |
DCM::EndorsingAuthority.Address | |
DCM::EndorsingAuthority.Name | NFU & V&VN |
DCM::EndorsingAuthority.Telecom | |
DCM::Id | 2.16.840.1.113883.2.4.3.11.60.40.3.13.4 |
DCM::KeywordList | Uitkomst van zorg, zorgresultaat |
DCM::LifecycleStatus | Final |
DCM::ModelerList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::Name | nl.nfu.UitkomstVanZorg |
DCM::PublicationDate | 8-9-2015 |
DCM::PublicationStatus | Published |
DCM::ReviewerList | Projectgroep RadB Verpleegkundige Gegevens & Kerngroep Registratie aan de Bron |
DCM::RevisionDate | 8-9-2015 |
DCM::Superseeds | |
DCM::Version | 1.0 |
HCIM::PublicationLanguage | EN |
Revision History
Only available in Dutch
Publicatieversie 1.0 (01-07-2015).
Concept
The Healthcare Results (healthcare results) concept describes the determined status of the patient in terms of a certain problem. Comparing the healthcare result with the treatment goal provides insight into the effectivity of the nursing interventions/activities carried out for this problem. It is a part of the nursing process, together with nursing diagnoses/problems, the treatment goal and nursing interventions.
There are different classification systems that describe healthcare results with a measurement value, such as the NOC (Nursing Outcome Classification), Omaha System, and ICF (International Classification of Functioning, Disability and Health). One of these classifications is to be used if possible.
Purpose
Healthcare results are important parameters for evaluating the patient’s health and monitoring the effectivity of the medical treatment and nursing interventions.
Information Model
Type | Id | Concept | Card. | Definition | DefinitionCode | Reference | |||||||
NL-CM:13.4.1 | HealthcareResult | Root concept of the HealthcareResult building block. This root concept contains all data elements of the HealthcareResult building block. | |||||||||||
NL-CM:13.4.5 | HealthcareResult | (0..1) | The textual account of the healthcare result. If HealthcareResult cannot be entered as a measurement value or functional/mental status, it can be described as free text in the healthcare result. |
|
|||||||||
NL-CM:13.4.2 | MeasurementValue::GeneralMeasurement | (0..1) | Measurements in which an observation, carried out with a (measuring) tool if possible, is translated to a relevant unit. |
| |||||||||
NL-CM:13.4.3 | HealthCondition::FunctionalOrMentalStatus | (0..1) | A description of the patient’s health condition in the form of a functional and/or mental status. |
| |||||||||
NL-CM:13.4.4 | Intervention::NursingIntervention | 0..1 | A description of the nursing intervention of which the effectivity is evaluated with the healthcare result. |
|
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
UitkomstVanZorg | |
Meetwaarde | |
ResultaatStatus | Definitief |
Toelichting | Waarschijnlijk delier. |
MeetUitslag | |
MetingNaam | Delirium observatie screening (DOS) |
UitslagWaarde | 7 |
UitslagDatumTijd | 10-09-2014 |
Interventie | |
Interventie | Waarborgen van veiligheid. |
This information model in other releases
- Release 2016, (Version 3.0)
- Release 2017, (Version 3.1)
- Prerelease 2018-2, (Version 3.1)
- Prerelease 2019-2, (Version 3.1)
- Release 2020, (Version 3.2)
- Prerelease 2021-2, (Version 3.3)
- Prerelease 2022-1, (Version 3.3)
- Prerelease 2023-1, (Version 3.3.1)
- Prerelease 2024-1, (Version 3.3.1)
Information model references
This information model refers to
This information model is used in
- --
Technical specifications in HL7v3 CDA and HL7 FHIR
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
- HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
- HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
Downloads
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Registratie aan de bron publication 2015 including errata dd. 16-07-2015
Conditions for use are located on the mainpage
This page is generated on 24/12/2018 12:36:53 with ZibExtraction v. 3.0.6932.1989