BodyTemperature-v3.0(2016EN): verschil tussen versies
(Copy of) |
Geen bewerkingssamenvatting |
||
(Een tussenliggende versie door dezelfde gebruiker niet weergegeven) | |||
Regel 1: | Regel 1: | ||
==General information== | <!-- Hieronder wordt een transclude page aangeroepen --> | ||
Name: '''nl.zorg.BodyTemperature''' [[Bestand:NL.png|link=Lichaamstemperatuur-v3.0(2016NL)]]<BR> | {{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.12.6(EN)|1|BodyTemperature-v3.0(2016EN)}} | ||
Version: '''3.0''' <br> | <!-- Tot hier de transclude page --> | ||
HCIM Status:Final<br> | ==General information<!--hdGeneralInformation-->== | ||
Release: '''2016''' <br> | Name<!--hdName-->: '''nl.zorg.BodyTemperature''' [[Bestand:NL.png|link=Lichaamstemperatuur-v3.0(2016NL)]]<BR> | ||
Release status: Published<br> | Version<!--hdVersion-->: '''3.0''' <br> | ||
Release date: 1-5-2016 | HCIM Status<!--hdStatus-->:Final<br> | ||
Release<!--hdPublication-->: '''2016''' <br> | |||
Release status<!--hdPublicationStatus-->: Published<br> | |||
Release date<!--hdPublicationDate-->: 1-5-2016 | |||
----- | ----- | ||
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2016(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2016(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> | ||
==Metadata== | ==Metadata== | ||
Regel 61: | Regel 64: | ||
==Revision History== | ==Revision History== | ||
<div class="mw-collapsible mw-collapsed"> | <div class="mw-collapsible mw-collapsed"> | ||
''Only available in Dutch'' | ''Only available in Dutch<!--noTranslation-->'' | ||
<u>Publicatieversie 1.0</u> (15-02-2013) | <u>Publicatieversie 1.0</u> (15-02-2013) | ||
Regel 132: | Regel 135: | ||
==Information Model== | ==Information Model== | ||
<BR> | <BR> | ||
<imagemap> Bestand:BodyTemperature-v3.0Model( | <imagemap> Bestand:BodyTemperature-v3.0Model(2016EN).png | center | ||
rect | rect 586 258 738 305 [[#TemperatureTypeCodelist]] | ||
rect | rect 205 95 313 165 [[#9541]] | ||
rect | rect 363 246 513 316 [[#9544]] | ||
rect | rect 590 94 734 164 [[#9542]] | ||
rect | rect 205 246 313 316 [[#9543]] | ||
rect | rect 381 95 495 165 [[#9540]] | ||
desc none | desc none | ||
</imagemap> | </imagemap> | ||
Regel 144: | Regel 147: | ||
{| border= "1" width="1500px" style = "font-size: 9.5pt; border: solid 1px silver; border-collapse:collapse;" cellpadding = "3px" cellspacing ="0px" | {| border= "1" width="1500px" style = "font-size: 9.5pt; border: solid 1px silver; border-collapse:collapse;" cellpadding = "3px" cellspacing ="0px" | ||
|-style="background-color: #1F497D; color: white; font-weight: bold; font-variant: small-caps; " | |-style="background-color: #1F497D; color: white; font-weight: bold; font-variant: small-caps; " | ||
|style="width:30px;"|Type||style="width:100px;"|Id||colspan="6 " style="width:140px;"|Concept||Card.||style="width: 600px;"|Definition||style="width:200px;"|DefinitionCode||style="width:200px;"|Reference | |style="width:30px;"|Type<!--imType-->||style="width:100px;"|Id<!--imId-->||colspan="6 " style="width:140px;"|Concept<!--imConcept-->||Card.<!--imCard-->||style="width: 600px;"|Definition<!--imDefinition-->||style="width:200px;"|DefinitionCode<!--imDefinitionCode-->||style="width:200px;"|Reference<!--imReference--> | ||
|-style="vertical-align:top; background-color: #E3E3E3; " | |-style="vertical-align:top; background-color: #E3E3E3; " | ||
|style = "text-align:center" |[[Bestand: block.png| 20px | link=]] | |style = "text-align:center" |[[Bestand: block.png| 20px | link=]] | ||
Regel 163: | Regel 166: | ||
{| | {| | ||
|- | |- | ||
|<span | |<span title = "Codesystem: SNOMED CT>[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=386725007 386725007] Body temperature (observable entity)</span> | ||
</span> | |||
|} | |} | ||
| | | | ||
Regel 199: | Regel 201: | ||
|} | |} | ||
|} | |} | ||
Columns Concept and DefinitionCode: hover over the values for more information<BR> | Columns Concept and DefinitionCode: hover over the values for more information<!--imHover--><BR> | ||
For explanation of the symbols, please see the legend page [[Bestand:list2.png|link=Legend]] | For explanation of the symbols, please see the legend page<!--imLegend--> [[Bestand:list2.png|link=Legend<!--wikiLegend-->]] | ||
==Example Instances== | ==Example Instances== | ||
''Only available in Dutch'' | ''Only available in Dutch<!--noTranslation-->'' | ||
{|class="wikitable" width="542px" style= "font-size: 9.5pt;" | {|class="wikitable" width="542px" style= "font-size: 9.5pt;" | ||
Regel 227: | Regel 229: | ||
{| class="wikitable" width="60%" | {| class="wikitable" width="60%" | ||
|-style='vertical-align:top; background-color: #E8D7BE;' | |-style='vertical-align:top; background-color: #E8D7BE;' | ||
|Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.12.6.1 | |Valueset OID<!--vsValuesetOID-->: 2.16.840.1.113883.2.4.3.11.60.40.2.12.6.1 | ||
|Binding<!--vsBindingTag-->: | |||
|} | |} | ||
{| class="wikitable" width="60% " | {| class="wikitable" width="60% " | ||
|-style="background-color: #1F497D; color: white; font-weight: bold; " | |-style="background-color: #1F497D; color: white; font-weight: bold; " | ||
|Conceptname | |Conceptname<!--vsConceptName--> | ||
|Conceptcode | |Conceptcode<!--vsConceptCode--> | ||
|Codesystem name||Codesystem OID | |Codesystem name<!--vsConceptSystemName-->||Codesystem OID<!--vsConceptSystemOID--> | ||
|Description | |Description<!--vsDescription--> | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Rectal temperature | |Rectal temperature | ||
|307047009 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=307047009 307047009] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 243: | Regel 246: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Oral temperature | |Oral temperature | ||
|415945006 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=415945006 415945006] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 249: | Regel 252: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Axillary temperature | |Axillary temperature | ||
|415882003 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=415882003 415882003] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 255: | Regel 258: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Groin temperature | |Groin temperature | ||
|415929009 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=415929009 415929009] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 261: | Regel 264: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Tympanic temperature | |Tympanic temperature | ||
|415974002 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=415974002 415974002] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 267: | Regel 270: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Forehead temperature | |Forehead temperature | ||
|415922000 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=415922000 415922000] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 273: | Regel 276: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Temperature of vagina | |Temperature of vagina | ||
|364246006 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=364246006 364246006] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 279: | Regel 282: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Bladder temperature | |Bladder temperature | ||
|698832009 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=698832009 698832009] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 285: | Regel 288: | ||
|-style="vertical-align:top; " | |-style="vertical-align:top; " | ||
|Core body temperature | |Core body temperature | ||
|276885007 | |[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=276885007 276885007] | ||
|SNOMED CT | |SNOMED CT | ||
|2.16.840.1.113883.6.96 | |2.16.840.1.113883.6.96 | ||
Regel 291: | Regel 294: | ||
|} | |} | ||
==This information model in other releases<!--ftOtherReleases-->== | |||
==This information model in other releases== | <!-- Hieronder wordt een transclude page aangeroepen --> | ||
< | {{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.12.6(EN)|2|2016}} | ||
<!-- Tot hier de transclude page --> | |||
< | ==Information model references<!--ftReferences-->== | ||
< | ====This information model refers to<!--ftRefersTo-->==== | ||
== | :-- | ||
====This information model is used in<!--ftReferredBy-->==== | |||
:-- | |||
==Technical specifications in HL7v3 CDA and HL7 FHIR<!--ftHeader-->== | |||
To exchange information based on health and care information models, additional, more technical specifications are required.<BR> | To exchange information based on health and care information models, additional, more technical specifications are required.<BR> | ||
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications: | Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro--> | ||
<ul> | <ul> | ||
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2016bbr-?id=2.16.840.1.113883.2.4.3.11.60.6.4.2.12.6&effectiveDate=2016-05-01T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li> | <li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2016bbr-?id=2.16.840.1.113883.2.4.3.11.60.6.4.2.12.6&effectiveDate=2016-05-01T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li> | ||
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR | <li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2016}}</li> | ||
</ul> | </ul> | ||
This information model is also available as [[Media:nl.zorg.BodyTemperature-v3.0(2016EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.zorg.BodyTemperature-v3.0(2016EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]] | ==Downloads<!--ftDownloadTitle-->== | ||
==About this information== | This information model is also available as [[Media:nl.zorg.BodyTemperature-v3.0(2016EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.zorg.BodyTemperature-v3.0(2016EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]<!--ftDownloads--> | ||
The information in this wikipage is based on Release summer 2016 <BR> | ==About this information<!--ftHeader2-->== | ||
Conditions for use are located on the mainpage [[Bestand:list2.png|link=HCIM_Mainpage]]<BR> | The information in this wikipage is based on<!--ftInfoBase--> Release summer 2016 <BR> | ||
This page is generated on | Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR> | ||
This page is generated on 21/12/2018 15:39:20 with ZibExtraction v. 3.0.6929.24609<!--ftDate--> <BR> | |||
----- | ----- | ||
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2016(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2016(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> |
Huidige versie van 24 dec 2018 om 12:08
General information
Name: nl.zorg.BodyTemperature
Version: 3.0
HCIM Status:Final
Release: 2016
Release status: Published
Release date: 1-5-2016
Metadata
DCM::CoderList | Kerngroep Registratie aan de Bron |
DCM::ContactInformation.Address | * |
DCM::ContactInformation.Name | * |
DCM::ContactInformation.Telecom | * |
DCM::ContentAuthorList | Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron |
DCM::CreationDate | 12-11-2012 |
DCM::DeprecatedDate | |
DCM::DescriptionLanguage | nl |
DCM::EndorsingAuthority.Address | |
DCM::EndorsingAuthority.Name | PM |
DCM::EndorsingAuthority.Telecom | |
DCM::Id | 2.16.840.1.113883.2.4.3.11.60.40.3.12.6 |
DCM::KeywordList | temperatuur, lichaamstemperatuur |
DCM::LifecycleStatus | Final |
DCM::ModelerList | Kerngroep Registratie aan de Bron |
DCM::Name | nl.zorg.Lichaamstemperatuur |
DCM::PublicationDate | 1-5-2016 |
DCM::PublicationStatus | Published |
DCM::ReviewerList | Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron |
DCM::RevisionDate | 16-7-2015 |
DCM::Superseeds | nl.nfu.Lichaamstemperatuur-v1.2.1 |
DCM::Version | 3.0 |
HCIM::PublicationLanguage | EN |
Revision History
Only available in Dutch
Publicatieversie 1.0 (15-02-2013)
Publicatieversie 1.1 (01-07-2013)
Publicatieversie 1.2 (01-04-2015)
ZIB-147 | Aanpassingen in SNOMED CT codes en omschrijvingen voor codelijst TemperatuurMetingMethodeCodelijst n.a.v. review terminologie expert. |
ZIB-276 | In de klinische bouwsteen OverdrachtTemperatuur kwam de tagged value van concept TemperatuurMetingMethode niet overeen met de onderliggende waardenlijst. |
ZIB-308 | Prefix Overdracht weggehaald bij de generieke bouwstenen |
ZIB-355 | Naamgeving bouwsteen aanpassen. |
ZIB-359 | Aanpassen conceptnaam en waardelijst van het concept TemperatuurMetingMethode |
Incl. algemene wijzigingsverzoeken:
ZIB-94 | Aanpassen tekst van Disclaimer, Terms of Use & Copyrights |
ZIB-154 | Consequenties opsplitsing Medicatie bouwstenen voor overige bouwstenen. |
ZIB-200 | Naamgeving SNOMED CT in tagged values klinische bouwstenen gelijk getrokken. |
ZIB-201 | Naamgeving OID: in tagged value notes van klinische bouwstenen gelijk getrokken. |
ZIB-309 | EOI aangepast |
ZIB-324 | Codelijsten Name en Description beginnen met een Hoofdletter |
ZIB-326 | Tekstuele aanpassingen conform de kwaliteitsreview kerngroep 2015 |
Publicatieversie 1.2.1 (16-07-2015)
ZIB-419 | Onjuiste SNOMED CT code in TemperatuurTypeCodelijst. |
Publicatieversie 3.0 (01-05-2016)
.
Concept
Measuring and documenting the body temperature of a person as a surrogate for a person’s central body temperature (the highest temperature at the centre of the torso)
Purpose
Measuring the body temperature is of medical importance. A number of diseases are accompanied by characteristic changes in body temperature. The symptoms of some diseases can be tracked by measuring the body temperature. The healthcare provider can use this temperature development to determine the effect of the treatment.
Information Model
Type | Id | Concept | Card. | Definition | DefinitionCode | Reference | |||||||
NL-CM:12.6.1 | BodyTemperature | Root concept of the BodyTemperature information model. This root concept contains all data elements of the BodyTemperature information model. | |||||||||||
NL-CM:12.6.2 | TemperatureValue | 1 | Body temperature is the temperature inside the body, measured in °C (degrees Celsius). The measurement method must be specified for a correct interpretation of the measurement value. |
|
|||||||||
NL-CM:12.6.4 | TemperatureDateTime | 1 | Date and time of measurement. | ||||||||||
NL-CM:12.6.3 | Explanation | 0..1 | Comments or details that may be of importance in interpreting the measurement value. | ||||||||||
NL-CM:12.6.5 | TemperatureType | 0..1 | The anatomical location where the body temperature was measured. |
|
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
Temperatuur DatumTijd | TemperatuurWaarde | Temperatuur Type | Toelichting |
08-02-2013 6:43 | 38,6 °C | Tympanische temperatuur | Voeten voelen heel koud aan |
References
1. Parelsnoer DCM Lichaamstemperatuur v0.10 [Online] Beschikbaar op: http://www.nictiz.nl/uploaded/FILES/htmlcontent/dcm/parelsnoer/nl.parelsnoer.Lichaamstemperatuur.v0.10.pdf [Geraadpleegd: 23 februari 2015].
2. openEHR-EHR-OBSERVATION.temperature.v1[Online] Beschikbaar op: http://www.openehr.org/knowledge/ [Geraadpleegd: 23 februari 2015].
Valuesets
TemperatureTypeCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.6.1 | Binding: |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
Rectal temperature | 307047009 | SNOMED CT | 2.16.840.1.113883.6.96 | Rectale temperatuur |
Oral temperature | 415945006 | SNOMED CT | 2.16.840.1.113883.6.96 | Orale temperatuur (onder de tong) |
Axillary temperature | 415882003 | SNOMED CT | 2.16.840.1.113883.6.96 | Axillaire temperatuur (onder de oksel) |
Groin temperature | 415929009 | SNOMED CT | 2.16.840.1.113883.6.96 | Inguinale temperatuur (via de lies) |
Tympanic temperature | 415974002 | SNOMED CT | 2.16.840.1.113883.6.96 | Tympanische temperatuur |
Forehead temperature | 415922000 | SNOMED CT | 2.16.840.1.113883.6.96 | Temporale temperatuur |
Temperature of vagina | 364246006 | SNOMED CT | 2.16.840.1.113883.6.96 | Vaginale temperatuur |
Bladder temperature | 698832009 | SNOMED CT | 2.16.840.1.113883.6.96 | Blaastemperatuur |
Core body temperature | 276885007 | SNOMED CT | 2.16.840.1.113883.6.96 | Kern temperatuur (invasief gemeten) |
This information model in other releases
- Release 2015, (Version 1.2.1)
- Release 2017, (Version 3.1)
- Prerelease 2018-2, (Version 3.1.1)
- Prerelease 2019-2, (Version 3.1.1)
- Release 2020, (Version 3.1.2)
- Prerelease 2021-2, (Version 3.1.2)
- Prerelease 2022-1, (Version 3.1.2)
- Prerelease 2023-1, (Version 3.1.2)
- Prerelease 2024-1, (Version 3.1.2)
Information model references
This information model refers to
- --
This information model is used in
- --
Technical specifications in HL7v3 CDA and HL7 FHIR
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
- HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
- HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
Downloads
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Release summer 2016
Conditions for use are located on the mainpage
This page is generated on 21/12/2018 15:39:20 with ZibExtraction v. 3.0.6929.24609